EUVIMEDEUVIMED entdecken
Crossref

Strategically Acquired Gradient Echo (STAGE) Imaging, part IV: Constrained Reconstruction of White Noise (CROWN) Processing as a Means to Improve Signal-to-Noise in STAGE Imaging at 3 Tesla

E Mark Haacke, Qiuyun Xu, Paul Kokeny, Sara Gharabaghi, Yongsheng Chen, Bo Wu, Yu Liu, Naying He, Fuhua Yan

Magnetic Resonance Imaging · 2024-04 · 107 · 55-68

DOI: 10.1016/j.mri.2024.01.001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance Imaging, 2024-04. Verfasst von E Mark Haacke und 8 weiteren Autor:innen. Beteiligte Einrichtung: SpinTech MRI, Bingham Farms, MI 48025, United States of America; Wayne State University, Department of Neurology, Detroit, MI 48201, United States of…. Hauptthemen laut MEDLINE: Image Processing, Computer-Assisted, Image Enhancement. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 54 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Increasing the signal-to-noise ratio (SNR) has always been of critical importance for magnetic resonance imaging. Although increasing field strength provides a linear increase in SNR, it is more and more costly as field strength increases. Therefore, there is a major effort today to use signal processing methods to improve SNR since it is more efficient and economical. There are a variety of methods to improve SNR such as averaging the data at the expense of imaging time, or collecting the data with a lower resolution, all of these methods, including imaging processing methods, usually come at the expense of loss of image detail or image blurring. Therefore, we developed a new mathematical approach called CROWN (Constrained Reconstruction of White Noise) to enhance SNR without loss of structural detail and without affecting scanning time. In this study, we introduced and tested the concept behind CROWN specifically for STAGE (strategically acquired gradient echo) imaging. The concept itself is presented first, followed by simulations to demonstrate its theoretical effectiveness. Then the SNR improvement on proton spin density (PSD) and R2⁎ maps was investigated using brain STAGE data acquired from 10 healthy controls (HCs) and 10 patients with Parkinson's disease (PD). For the PSD and R2* maps, the SNR and CNR between white matter and gray matter were improved by a factor of 1.87 ± 0.50 and 1.72 ± 0.88, respectively. The white matter hyperintensity lesions in PD patients were more clearly defined after CROWN processing. Using these improved maps, simulated images for any repeat time, echo time or flip angle can be created with improved SNR. The potential applications of this technology are to trade off the increased SNR for higher resolution images and/or faster imaging.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Image Processing, Computer-AssistedImage EnhancementHumansBrainGray MatterBrain MappingMagnetic Resonance ImagingSignal-To-Noise Ratio

Stichwörter der Autor:innen

CROWNProton spin density mappingR2(⁎) mappingSTAGE imagingSignal-to-noise ratioT1 mapping

Autor:innen und Institutionen

  • SpinTech MRI, Bingham Farms, MI 48025, United States of America; Wayne State University, Department of Neurology, Detroit, MI 48201, United States of America; Wayne State University, Department of Radiology, Detroit, MI…
  • SpinTech MRI, Bingham Farms, MI 48025, United States of America.
  • Wayne State University, Department of Neurology, Detroit, MI 48201, United States of America.
  • Zhuyan Limited, Shanghai, China.
  • Ruijin Hospital, School of Medicine, Shanghai Jiao Tong University, Department of Radiology, Shanghai, China.

Zitieren

APA

Haacke, E. M., Xu, Q., Kokeny, P., Gharabaghi, S., Chen, Y., Wu, B., Liu, Y., He, N., & Yan, F. (2024). Strategically Acquired Gradient Echo (STAGE) Imaging, part IV: Constrained Reconstruction of White Noise (CROWN) Processing as a Means to Improve Signal-to-Noise in STAGE Imaging at 3 Tesla. Magnetic Resonance Imaging, 107, 55-68. https://doi.org/10.1016/j.mri.2024.01.001

Vancouver

Haacke EM, Xu Q, Kokeny P, Gharabaghi S, Chen Y, Wu B, et al. Strategically Acquired Gradient Echo (STAGE) Imaging, part IV: Constrained Reconstruction of White Noise (CROWN) Processing as a Means to Improve Signal-to-Noise in STAGE Imaging at 3 Tesla. Magnetic Resonance Imaging. 2024;107:55-68. doi:10.1016/j.mri.2024.01.001

BibTeX
@article{Haacke2024,
  author = {Haacke, E Mark and Xu, Qiuyun and Kokeny, Paul and Gharabaghi, Sara and Chen, Yongsheng and Wu, Bo and Liu, Yu and He, Naying and Yan, Fuhua},
  title = {Strategically Acquired Gradient Echo (STAGE) Imaging, part IV: Constrained Reconstruction of White Noise (CROWN) Processing as a Means to Improve Signal-to-Noise in STAGE Imaging at 3 Tesla},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  volume = {107},
  pages = {55--68},
  doi = {10.1016/j.mri.2024.01.001}
}
Kostenlos starten →