Age‐Specific Contrast Optimization of bSSFP in Fetal Brain

Qinfeng Zhu iD, Xin Chen, Haotian Li iD, Xingwang Yong iD, Haoan Xu iD, Xinyi Xu, Xingzhou Chen iD, Nuowei Ge, Yi-Cheng Hsu, Xu Yan, Chengbo Wang iD, Congbo Cai und 1 weitere

Magnetic Resonance in Medicine · 2026-10 · 96 (4) · 1645-1654

DOI: 10.1002/mrm.70452 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 12.06.2026. Verfasst von Qinfeng Zhu und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Brain, Fetus, Image Processing, Computer-Assisted. Die Arbeit nennt 43 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Natural Science Foundation of China, Young Investigator Program of United Imaging, Key Research & Development Project of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Balanced steady‐state free‐precession (bSSFP) enables rapid fetal brain acquisition but suffers from inherently low tissue contrast. This study aims to develop an age‐specific optimization strategy for bSSFP to enhance gray matter–white matter (GM–WM) contrast in the developing fetal brain.

Methods

An optimization pipeline was designed for 2D and 3D bSSFP sequences, integrating the Transition Into Driven Equilibrium (TIDE) model with the extended phase graph (EPG) algorithm. Using T1 and T2 relaxation times measured from fetal brains, the pipeline derived age‐specific variable flip angle (VFA) trains to maximize GM–WM contrast while constraining signal‐to‐noise ratio (SNR) and point‐spread function. Performance was benchmarked against default bSSFP and T2‐weighted half‐Fourier acquisition single‐shot turbo spin echo (HASTE) sequences based on relative contrast and segmentation accuracy.

Results

The contrast enhancement was evaluated in a cohort of 18 fetal brains from 24 to 37 gestational weeks. The optimized 2D and 3D bSSFP sequences yielded significantly higher relative cortical contrast compared with the default bSSFP ( p < 0.001 for 2D and p < 0.002 for 3D), achieving average improvements of 4.13‐fold and 4.06‐fold, respectively. Furthermore, in the segmentation tasks, the optimized images yielded substantially higher segmentation accuracy compared with HASTE images (DICE = 0.93 for optimized 2D bSSFP and 0.89 for optimized 3D bSSFP, vs. 0.79 for HASTE).

Conclusions

The proposed age‐specific bSSFP optimization strategy enhanced the characterization of GM–WM contrast in fetuses of different gestational ages. This readily translatable method holds potential to advance both clinical assessments and neurodevelopmental studies of the fetal brain.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance ImagingBrainFetusImage Processing, Computer-AssistedHumansAlgorithmsFemaleSignal-To-Noise RatioImaging, Three-DimensionalGestational AgeWhite MatterPregnancyImage EnhancementGray Matter

Autor:innen und Institutionen

  • Department of Biomedical Engineering, College of Biomedical Engineering & Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.
  • Department of Radiology, Shandong Provincial Hospital Affiliated to Shandong First Medical University, Jinan, Shandong, China.
  • Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, Fujian, China.
  • MR Collaboration, Siemens Healthcare China, Shanghai, China.
  • Department of Electrical and Electronic Engineering, Faculty of Science and Engineering, University of Nottingham Ningbo China, Ningbo, Zhejiang, China.
  • National Clinical Research Center for Child Health, Children's Hospital, Zhejiang University School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China.

ORCID-Profile: Qinfeng Zhu, Haotian Li, Xingwang Yong, Haoan Xu, Xingzhou Chen, Chengbo Wang, Dan Wu

Förderung

  • National Natural Science Foundation of China
  • Young Investigator Program of United Imaging
  • Key Research & Development Project of Zhejiang Province

Zitieren

APA

Zhu, Q., Chen, X., Li, H., Yong, X., Xu, H., Xu, X., Chen, X., Ge, N., Hsu, Y. C., Yan, X., Wang, C., Cai, C., & Wu, D. (2026). Age‐Specific Contrast Optimization of bSSFP in Fetal Brain. Magnetic Resonance in Medicine, 96(4), 1645-1654. https://doi.org/10.1002/mrm.70452

Vancouver

Zhu Q, Chen X, Li H, Yong X, Xu H, Xu X, et al. Age‐Specific Contrast Optimization of bSSFP in Fetal Brain. Magnetic Resonance in Medicine. 2026;96(4):1645-1654. doi:10.1002/mrm.70452

BibTeX
@article{Zhu2026,
  author = {Zhu, Qinfeng and Chen, Xin and Li, Haotian and Yong, Xingwang and Xu, Haoan and Xu, Xinyi and Chen, Xingzhou and Ge, Nuowei and Hsu, Yi-Cheng and Yan, Xu and Wang, Chengbo and Cai, Congbo and Wu, Dan},
  title = {Age‐Specific Contrast Optimization of bSSFP in Fetal Brain},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {4},
  pages = {1645--1654},
  doi = {10.1002/mrm.70452}
}
Kostenlos starten →