Improved image quality and reduced acquisition time in brain MRI using deep learning-based reconstruction: A quantitative and subjective assessment compared to standard MPRAGE in 0.55 T MRI
Magnetic Resonance Imaging · 2026-06 · 129 · 110656
DOI: 10.1016/j.mri.2026.110656 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Magnetic Resonance Imaging, 2026-06. Verfasst von Saher Saeed und 15 weiteren Autor:innen. Beteiligte Einrichtung: Ruhr University Bochum, Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling Hospital, Hans-Nolte-Str. 1, 32429 Minden, Ger…. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Brain, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
PURPOSE: To assess the impact of deep learning (DL)-based image reconstruction on quantitative and subjective image quality in brain MRI at 0.55 T by comparing DL-reconstructed MPRAGE with standard MPRAGE using comparable acquisition geometry and timing parameters. METHODS: In this prospective study, 30 patients underwent two consecutive 3D T1-weighted MPRAGE acquisitions on a 0.55 T MRI system (MAGNETOM Free.Max, Siemens Healthineers): a standard reconstruction and a DL-based reconstruction generated from undersampled k-space data using a variational-network architecture. Identical circular regions of interest (ROIs) were placed in gray matter (caudate nucleus), white matter (centrum semiovale), cerebrospinal fluid (lateral ventricle), and air for noise estimation. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were computed. Three blinded radiologists independently evaluated image quality using a 5-point Likert scale based on anatomical detail, gray-white matter differentiation, vascular visibility, artifact burden, and overall diagnostic quality. RESULTS: DL-based reconstruction significantly improved objective image quality across all metrics. SNR increased from 40.83 ± 10.11 to 106.30 ± 51.38 in gray matter (p < 0.0001), from 48.95 ± 12.52 to 125.30 ± 58.01 in white matter (p < 0.0001), and from 5.77 ± 1.10 to 7.75 ± 4.76 in CSF (p = 0.021). CNR between gray and white matter increased from 8.12 ± 4.24 to 18.99 ± 11.21 (p < 0.0001). Subjective ratings favored DL reconstruction for anatomical detail (4.05 ± 0.62 vs. 3.68 ± 0.64), vascular visibility (4.37 ± 0.56 vs. 3.63 ± 0.72), and overall image quality (4.07 ± 0.72 vs. 3.57 ± 0.73). Standard reconstruction showed slightly better artifact suppression (3.80 ± 0.61 vs. 3.27 ± 0.78) and gray-white matter contrast (4.00 ± 0.64 vs. 3.87 ± 0.71). Acquisition time was reduced from 6:44 min (standard MPRAGE) to 3:06 min with DL reconstruction, corresponding to a substantial scan time reduction. CONCLUSION: DL-based reconstruction markedly enhances quantitative and subjective image quality in low-field brain MRI and enables a markedly shorter acquisition time compared to the standard protocol. This study adds clinical evidence that DL reconstruction can substantially improve 0.55 T MPRAGE imaging, supporting its integration into routine neuroimaging workflows to improve efficiency, patient comfort, and diagnostic confidence.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ruhr University Bochum, Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling Hospital, Hans-Nolte-Str. 1, 32429 Minden, Germany. Electronic address: Saher.Saeed@muehlenkreiskliniken.de.
- Research & Clinical Translation, Magnetic Resonance, Siemens Healthineers AG, Erlangen, Germany.
- Scientific Partnerships, Siemens Healthineers AG, Erlangen, Germany.
- Ruhr University Bochum, Department of Radiology, Neuroradiology and Nuclear Medicine, Johannes Wesling Hospital, Hans-Nolte-Str. 1, 32429 Minden, Germany.
Zitieren
APA
Saeed, S., Nickel, D., Weiland, E., Frohwein, L. J., Niehoff, J. H., Reiman, G., Schreck, J., Haag, N., Boriesosdick, J., Schoenbeck, D., Katz, M., Shahzadi, I., Woeltjen, M. M., Kroeger, J. R., Borggrefe, J., & Moenninghoff, C. (2026). Improved image quality and reduced acquisition time in brain MRI using deep learning-based reconstruction: A quantitative and subjective assessment compared to standard MPRAGE in 0.55 T MRI. Magnetic Resonance Imaging, 129, 110656. https://doi.org/10.1016/j.mri.2026.110656
Vancouver
Saeed S, Nickel D, Weiland E, Frohwein LJ, Niehoff JH, Reiman G, et al. Improved image quality and reduced acquisition time in brain MRI using deep learning-based reconstruction: A quantitative and subjective assessment compared to standard MPRAGE in 0.55 T MRI. Magnetic Resonance Imaging. 2026;129:110656. doi:10.1016/j.mri.2026.110656
BibTeX
@article{Saeed2026,
author = {Saeed, Saher and Nickel, Dominik and Weiland, Elisabeth and Frohwein, Lynn Johann and Niehoff, Julius Henning and Reiman, Georg and Schreck, Julian and Haag, Nina and Boriesosdick, Jan and Schoenbeck, Denise and Katz, Maria and Shahzadi, Iram and Woeltjen, Matthias Michael and Kroeger, Jan Robert and Borggrefe, Jan and Moenninghoff, Christoph},
title = {Improved image quality and reduced acquisition time in brain MRI using deep learning-based reconstruction: A quantitative and subjective assessment compared to standard MPRAGE in 0.55 T MRI},
journal = {Magnetic Resonance Imaging},
year = {2026},
volume = {129},
pages = {110656},
doi = {10.1016/j.mri.2026.110656}
}
EUVIMED