Deformable image registration for self-supervised cardiac phase detection in cardiac magnetic resonance images of patients with various diseases
Medical Image Analysis · 2026
DOI: 10.1016/j.media.2026.104142 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Image Analysis, 2026. Verfasst von Sarah Kaye Mueller und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine III, Heidelberg University Hospital, Heidelberg, 69120, Germany; Medical Faculty of Heidelberg University, Heidelberg…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cine, Image Interpretation, Computer-Assisted, Heart Defects, Congenital, Supervised Machine Learning. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Ministerium für Wissenschaft, Forschung und Kunst Baden-Württemberg, Carl-Zeiss-Stiftung.
Abstract (Originalsprache)
Cardiovascular magnetic resonance (CMR) is widely used to assess cardiac function, but individual cardiac cycles complicate automatic temporal comparison and sub-phase analysis. Accurate cardiac keyframe detection can eliminate this problem. However, automatic methods solely derive end-systole (ES) and end-diastole (ED) frames from left ventricular volume curves, which do not provide a deeper insight into myocardial motion. We propose a self-supervised deep learning method detecting five keyframes in short-axis (SAX) and four-chamber (4CH) cine CMR. Initially, dense deformable registration fields are derived from CMR to compute a 1D motion descriptor encoding global cardiac contraction and relaxation patterns. Keyframes are derived from these characteristic curves with a set of rules. The method was independently evaluated for both views using four databases encompassing multiple centre, vendor and disease. M&Ms-2 (n=360) was used for training and evaluation; M&Ms (n=345) and ACDC (n=100) for repeatability control. Generalisability to patients with rare congenital heart defects was tested using the German Competence Network (GCN) database. A disease-stratified analysis confirmed stable performance across cardiomyopathies and congenital abnormalities. Our method improved detection accuracy by 49%/59% for SAX and 31%/39% for 4CH in ED/ES over the volume-based approach, with mean cyclic frame difference (cFD) below 1.3 and 1.2 frames for SAX and 4CH respectively. Our framework enables temporally aligned inter- and intra-patient analysis of cardiac dynamics, irrespective of cycle or phase lengths for aligned strain analysis or temporal normalisation. Code and annotations are available at: https://github.com/Cardio-AI/cmr-multi-view-phase-detection.git.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine III, Heidelberg University Hospital, Heidelberg, 69120, Germany; Medical Faculty of Heidelberg University, Heidelberg, 69120, Germany. Electronic address: SarahKaye.Mueller@med.uni-heidel…
- Department of Internal Medicine III, Heidelberg University Hospital, Heidelberg, 69120, Germany.
- Department of Internal Medicine III, Heidelberg University Hospital, Heidelberg, 69120, Germany; DZHK (German Centre for Cardiovascular Research), Heidelberg, 69120, Germany.
- Division of Pediatric Cardiology, Department of Pediatrics, UT Southwestern/Children's Health, Dallas, USA.
- DZHK (German Centre for Cardiovascular Research), Heidelberg, 69120, Germany; German Competence Network for Congenital Heart Defects, Berlin, Germany; Department of Cardiothoracic, Transplantation and Vascular Surgery,…
- Department of Internal Medicine III, Heidelberg University Hospital, Heidelberg, 69120, Germany; Medical Faculty of Heidelberg University, Heidelberg, 69120, Germany; DZHK (German Centre for Cardiovascular Research), He…
Förderung
- Deutsche Forschungsgemeinschaft
- Ministerium für Wissenschaft, Forschung und Kunst Baden-Württemberg
- Carl-Zeiss-Stiftung
Zitieren
APA
Mueller, S. K., Koehler, S., Kiekenap, J., Greil, G., Hussain, T., Sarikouch, S., Andre, F., Frey, N., & Engelhardt, S. (2026). Deformable image registration for self-supervised cardiac phase detection in cardiac magnetic resonance images of patients with various diseases. Medical Image Analysis. https://doi.org/10.1016/j.media.2026.104142
Vancouver
Mueller SK, Koehler S, Kiekenap J, Greil G, Hussain T, Sarikouch S, et al. Deformable image registration for self-supervised cardiac phase detection in cardiac magnetic resonance images of patients with various diseases. Medical Image Analysis. 2026. doi:10.1016/j.media.2026.104142
BibTeX
@article{Mueller2026,
author = {Mueller, Sarah Kaye and Koehler, Sven and Kiekenap, Jonathan and Greil, Gerald and Hussain, Tarique and Sarikouch, Samir and Andre, Florian and Frey, Norbert and Engelhardt, Sandy},
title = {Deformable image registration for self-supervised cardiac phase detection in cardiac magnetic resonance images of patients with various diseases},
journal = {Medical Image Analysis},
year = {2026},
doi = {10.1016/j.media.2026.104142}
}
EUVIMED