Improving Clinical Utility of Fetal Cine CMR Using Deep Learning Super-Resolution
Circulation: Cardiovascular Imaging · 2025
DOI: 10.1161/circimaging.125.018090 ↗Kurz gefasst
Fachartikel in der Zeitschrift Circulation: Cardiovascular Imaging, 2025. Verfasst von Thomas M Vollbrecht und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology (T.M.V., C.H., A.I., M.B.V., C.C.P., D.K., J.A.L.), University Hospital Bonn, Germany. Hauptthemen laut MEDLINE: Deep Learning, Magnetic Resonance Imaging, Cine, Heart Defects, Congenital, Fetal Heart. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Fetal cardiovascular magnetic resonance is an emerging tool for prenatal congenital heart disease assessment, but long acquisition times and fetal movements limit its clinical use. This study evaluates the clinical utility of deep learning super-resolution reconstructions for rapidly acquired, low-resolution fetal cardiovascular magnetic resonance. METHODS: This prospective study included participants with fetal congenital heart disease undergoing fetal cardiovascular magnetic resonance in the third trimester of pregnancy, with axial cine images acquired at normal resolution and low resolution. Low-resolution cine data was subsequently reconstructed using a deep learning super-resolution framework (cine DL ). Acquisition times, apparent signal-to-noise ratio, contrast-to-noise ratio, and edge rise distance were assessed. Volumetry and functional analysis were performed. Qualitative image scores were rated on a 5-point Likert scale. Cardiovascular structures and pathological findings visible in cine DL images only were assessed. Statistical analysis included the Student paired t test and the Wilcoxon test. RESULTS: A total of 42 participants were included (median gestational age, 35.9 weeks [interquartile range (IQR), 35.1–36.4]). Cine DL acquisition was faster than cine images acquired at normal resolution (134±9.6 s versus 252±8.8 s; P
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostic and Interventional Radiology (T.M.V., C.H., A.I., M.B.V., C.C.P., D.K., J.A.L.), University Hospital Bonn, Germany.
- Quantitative Imaging Lab Bonn (QILaB) (T.M.V., C.H., A.I., D.K., J.A.L.), University Hospital Bonn, Germany.
- Department of Pediatric Cardiology (C.H.), University Hospital Bonn, Germany.
- Philips GmbH Market DACH, Hamburg, Germany (C.K.).
- Department of Obstetrics and Prenatal Medicine (A.G., B.S.), University Hospital Bonn, Germany.
ORCID-Profile: Christopher Hart, Christoph Katemann, Alexander Isaak, Marilia B Voigt, Claus C Pieper, Daniel Kuetting, Annegret Geipel, Brigitte Strizek, Julian A Luetkens
Zitieren
APA
Vollbrecht, T. M., Hart, C., Katemann, C., Isaak, A., Voigt, M. B., Pieper, C. C., Kuetting, D., Geipel, A., Strizek, B., & Luetkens, J. A. (2025). Improving Clinical Utility of Fetal Cine CMR Using Deep Learning Super-Resolution. Circulation: Cardiovascular Imaging. https://doi.org/10.1161/circimaging.125.018090
Vancouver
Vollbrecht TM, Hart C, Katemann C, Isaak A, Voigt MB, Pieper CC, et al. Improving Clinical Utility of Fetal Cine CMR Using Deep Learning Super-Resolution. Circulation: Cardiovascular Imaging. 2025. doi:10.1161/circimaging.125.018090
BibTeX
@article{Vollbrecht2025,
author = {Vollbrecht, Thomas M and Hart, Christopher and Katemann, Christoph and Isaak, Alexander and Voigt, Marilia B and Pieper, Claus C and Kuetting, Daniel and Geipel, Annegret and Strizek, Brigitte and Luetkens, Julian A},
title = {Improving Clinical Utility of Fetal Cine CMR Using Deep Learning Super-Resolution},
journal = {Circulation: Cardiovascular Imaging},
year = {2025},
doi = {10.1161/circimaging.125.018090}
}
EUVIMED