EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Multi‐Frame Image Registration for Automated Ventricular Function Assessment in Single Breath‐Hold Cine MRI Using Limited Labels

Aya Ghoul iD, Paxstan Cassal Paulson, Andreas Lingg iD, Patrick Krumm iD, Kerstin Hammernik iD, Daniel Rueckert iD, Sergios Gatidis iD, Thomas Küstner iD

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70137 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Aya Ghoul und 7 weiteren Autor:innen. Beteiligte Einrichtung: Medical Image and Data Analysis (MIDAS.lab), Department of Interventional and Diagnostic Radiology, University Hospital of Tuebingen, Tuebingen, Germ…. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Cine, Heart Ventricles, Image Processing, Computer-Assisted, Ventricular Function. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study aims to develop an automated framework for operator‐independent assessment of cardiac ventricular function from highly accelerated images.

Methods

We introduce a deep learning framework that generates reliable ventricular volumetric parameters and strain measures from fully sampled and retrospectively accelerated MR images. This method integrates image registration, motion‐compensated reconstruction, and segmentation in a synergetic loop for mutual refinement. The evaluation was performed on an in‐house dataset of healthy and cardiovascular‐diseased subjects. We examined the performance of the underlying tasks, including registration and segmentation, and their impact on derived parameters related to ventricular function.

Results

The proposed approach demonstrates robustness to undersampling artifacts and requires limited annotation, while still reducing variability and errors for segmentation and registration. This translates to a to increase in Dice similarity compared to existing deep learning methods for left endocardium, left epicardium, and right ventricular delineation. Analysis of the predicted left and right ventricular ejection fraction reveals a strong correlation () with manual measurements. Moreover, the estimated motion and segmentation masks enable consistent radial and circumferential strain measurements across accelerations up to .

Conclusion

A comprehensive ventricular function analysis can be performed using highly accelerated cine MR data with minimal annotation effort. This multitasking strategy has the potential to enable more accessible cardiac function analysis within a single breath‐hold.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance Imaging, CineHeart VentriclesImage Processing, Computer-AssistedVentricular FunctionHumansBreath HoldingDeep LearningAlgorithmsMaleImage Interpretation, Computer-AssistedFemaleReproducibility of ResultsAdultArtifactsRetrospective Studies

Stichwörter der Autor:innen

cine MRIdeep learningimage registrationmotion‐compensated reconstructionsegmentationstrain

Autor:innen und Institutionen

  • Medical Image and Data Analysis (MIDAS.lab), Department of Interventional and Diagnostic Radiology, University Hospital of Tuebingen, Tuebingen, Germany.
  • Institute of Signal Processing and System Theory, University of Stuttgart, Stuttgart, Germany.
  • School of Computation, Information and Technology, Technical University of Munich (TUM), Munich, Germany.
  • TUM University Hospital, Technical University of Munich (TUM), Munich, Germany.
  • Department of Computing, Imperial College London, London, UK.
  • Department of Radiology, Stanford University, Stanford, California, USA.

ORCID-Profile: Aya Ghoul, Andreas Lingg, Patrick Krumm, Kerstin Hammernik, Daniel Rueckert, Sergios Gatidis, Thomas Küstner

Zitieren

APA

Ghoul, A., Cassal Paulson, P., Lingg, A., Krumm, P., Hammernik, K., Rueckert, D., Gatidis, S., & Küstner, T. (2026). Multi‐Frame Image Registration for Automated Ventricular Function Assessment in Single Breath‐Hold Cine MRI Using Limited Labels. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70137

Vancouver

Ghoul A, Cassal Paulson P, Lingg A, Krumm P, Hammernik K, Rueckert D, et al. Multi‐Frame Image Registration for Automated Ventricular Function Assessment in Single Breath‐Hold Cine MRI Using Limited Labels. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70137

BibTeX
@article{Ghoul2026,
  author = {Ghoul, Aya and Cassal Paulson, Paxstan and Lingg, Andreas and Krumm, Patrick and Hammernik, Kerstin and Rueckert, Daniel and Gatidis, Sergios and Küstner, Thomas},
  title = {Multi‐Frame Image Registration for Automated Ventricular Function Assessment in Single Breath‐Hold Cine MRI Using Limited Labels},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70137}
}