Feasibility of automated treatment planning for HyperArc-based stereotactic recurrent head and neck cancers using knowledge-based planning, multicriteria optimization, and dosimetric scorecards
Medical Dosimetry · 2026
DOI: 10.1016/j.meddos.2025.09.005 ↗Kurz gefasst
Fachartikel in der Zeitschrift Medical Dosimetry, 2026. Verfasst von Shane McCarthy und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Medicine, University of Kentucky, Lexington KY 40536, USA. Hauptthemen laut MEDLINE: Radiotherapy Planning, Computer-Assisted, Head and Neck Neoplasms, Radiosurgery, Neoplasm Recurrence, Local. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Varian Medical Systems Inc.
Abstract (Originalsprache)
The development of a HyperArc-based automated stereotactic treatment planning process for recurrent head and neck (RHN) cancers using knowledge-based planning, multicriteria optimization (MCO), and dosimetric scorecards. Twenty-eight previously treated RHN HyperArc patients, prescribed 30 to 40 Gy in 5 fractions, were used to generate a RapidPlan model. An Eclipse Scripting script was created to automate the model's use and refine the model's output with MCO, where tradeoff exploration was guided by a dosimetric scorecard. Final dose, calculated with AcurosXB, was normalized to the original plan's PTV D95 %. Maximum doses to organs-at-risk (OARs), target metrics, calculation/optimization times and patient-specific quality assurance results were recorded. The automated treatment planning process took on average 12.1 ± 0.9 minutes to generate the RHN RapidPlan plan and an additional 25.0 ± 2.6 minutes for MCO exploration. The GTV mean dose stayed comparable across all plans with an average decrease of 0.8 ± 0.9 Gy from the original plan to the RapidPlan and an average increase of 0.3 ± 1.2 Gy from the original plan to the MCO plan. The PTV Paddick's conformity index received an average decrease of 0.01 ± 0.01 from original to RapidPlan and an increase of 0.02 ± 0.01 from the original plan to the MCO plan. All OAR maximum dose changes were favorable or remained within clinically acceptable dose levels for stereotactic delivery. The dose delivery accuracy for the final plans were verified with electronic portal imaging device-based portal dosimetry and an independent Monte Carlo second check reported averages of 97.2 % and 96.3 %, respectively, indicating accurate stereotactic delivery. The process established throughout this work offers an automated treatment planning routine, excluding contouring, for stereotactic RHN patients. Through automation, the treatment planning workflow is standardized and quickened, improving the clinical workflow, and expanding accessibility of high-quality HyperArc-based stereotactic treatments for RHN tumor.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Medicine, University of Kentucky, Lexington KY 40536, USA.
- Department of Radiation Medicine, University of Kentucky, Lexington KY 40536, USA. Electronic address: damodar.pokhrel@uky.edu.
Förderung
- Varian Medical Systems Inc
Zitieren
APA
McCarthy, S., St Clair, W., Yang, E. S., & Pokhrel, D. (2026). Feasibility of automated treatment planning for HyperArc-based stereotactic recurrent head and neck cancers using knowledge-based planning, multicriteria optimization, and dosimetric scorecards. Medical Dosimetry. https://doi.org/10.1016/j.meddos.2025.09.005
Vancouver
McCarthy S, St Clair W, Yang ES, Pokhrel D. Feasibility of automated treatment planning for HyperArc-based stereotactic recurrent head and neck cancers using knowledge-based planning, multicriteria optimization, and dosimetric scorecards. Medical Dosimetry. 2026. doi:10.1016/j.meddos.2025.09.005
BibTeX
@article{McCarthy2026,
author = {McCarthy, Shane and St Clair, William and Yang, Eddy S and Pokhrel, Damodar},
title = {Feasibility of automated treatment planning for HyperArc-based stereotactic recurrent head and neck cancers using knowledge-based planning, multicriteria optimization, and dosimetric scorecards},
journal = {Medical Dosimetry},
year = {2026},
doi = {10.1016/j.meddos.2025.09.005}
}
EUVIMED