EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Feasibility of treatment planning with HyperArc stereotactic radiosurgery methods for ocular tumors

Chase Cochran, Shane McCarthy iD, William St Clair, Damodar Pokhrel iD

Journal of Applied Clinical Medical Physics · 2025

DOI: 10.1002/acm2.70399 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2025. Verfasst von Chase Cochran und 3 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, Kentucky, USA. Hauptthemen laut MEDLINE: Radiosurgery, Radiotherapy Planning, Computer-Assisted, Organs at Risk, Eye Neoplasms. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose/objectives Currently, ocular disease is primarily managed with COMS plaque brachytherapy. Various stereotactic radiosurgery (SRS) platforms have also been employed, yet widespread access remains a challenge. Herein, we demonstrate the feasibility of using the HyperArc SRS system to provide an additional platform for the treatment of ocular malignancies. Materials/methods Twenty previously treated COMS patients with ocular melanoma were selected for a retrospective HyperArc SRS planning study. The average gross tumor volume (GTV) derived from MRI was 1.19 ± 0.60 cc. Planning target volumes (PTV) were generated from a 2 mm expansion of the GTVs. HyperArc plans were created for a TrueBeam LINAC (6MV‐FFF) with the Encompass support system and used the AcurosXB algorithm for dose calculation. A dose of 25 Gy was prescribed to the PTVs and all plans were normalized such that PTVD95% = 25 Gy. All organs at risk (OARs) were spared adequately. Patient‐specific quality assurance (QA) and an independent Monte Carlo (MC) second check was performed for all SRS plans.

Results

HyperArc plans demonstrated high conformality Paddick conformity index (PCI = 0.84 ± 0.04) with steep dose gradient index (GI = 3.29 ± 0.38). Compared to the HyTEC standard (12.1 Gy), it adequately spared the optic nerve(s) ( D max = 7.18 ± 1.26 Gy, p < 0.001). Adequate PTV coverage (D99% = 23.80 ± 0.46 Gy) was achieved with a mean GTV dose of 27.54 ± 0.47 Gy. Maximum dose to critical OARs were controlled: brain (6.00 ± 1.50 Gy), optic nerve (7.18 ± 1.26 Gy), and ipsilateral lens (9.36 ± 5.67 Gy). Average beam‐on time was under 9 min. End‐to‐end QA results showed a 99.00 ± 0.59% pass rate (2%/2 mm γ‐criteria), with a MC check showing 97.81 ± 1.24% agreement with the AcurosXB algorithm (2%/2 mm).

Conclusion

HyperArc SRS plans provided adequate target coverage, acceptable OARs sparing, and offer a fast, safe, and non‐invasive treatment option for ocular tumors. Clinical implementation of this novel methodology is ongoing at our institution.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiosurgeryRadiotherapy Planning, Computer-AssistedOrgans at RiskEye NeoplasmsMelanomaRadiotherapy, Intensity-ModulatedHumansRadiotherapy DosageRetrospective StudiesFeasibility StudiesMonte Carlo MethodAlgorithmsQuality Assurance, Health Care

Stichwörter der Autor:innen

HyperArc VMATOcular/Intraocular TumorsSRSend‐to‐end test

Autor:innen und Institutionen

  • Medical Physics Graduate Program, Department of Radiation Medicine, University of Kentucky, Lexington, Kentucky, USA.
  • Indiana University Health System, Department of Radiation Oncology, Indianapolis, Indiana, USA.

ORCID-Profile: Shane McCarthy, Damodar Pokhrel

Zitieren

APA

Cochran, C., McCarthy, S., St Clair, W., & Pokhrel, D. (2025). Feasibility of treatment planning with HyperArc stereotactic radiosurgery methods for ocular tumors. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70399

Vancouver

Cochran C, McCarthy S, St Clair W, Pokhrel D. Feasibility of treatment planning with HyperArc stereotactic radiosurgery methods for ocular tumors. Journal of Applied Clinical Medical Physics. 2025. doi:10.1002/acm2.70399

BibTeX
@article{Cochran2025,
  author = {Cochran, Chase and McCarthy, Shane and St Clair, William and Pokhrel, Damodar},
  title = {Feasibility of treatment planning with HyperArc stereotactic radiosurgery methods for ocular tumors},
  journal = {Journal of Applied Clinical Medical Physics},
  year = {2025},
  doi = {10.1002/acm2.70399}
}
Kostenlos starten →