EUVIMEDEUVIMED entdecken
Vergleichsstudie

Eccentric reaming is superior to augmented components in B2 glenoids: a biomechanical study

Zachary DeVries, Rashed AlAhmed, Ariane Parisien, Nicholas Nucci, Andrew Speirs, Kellen Walsh, J Whitcomb Pollock, Katie McIlquham, Peter Lapner

Journal of Shoulder and Elbow Surgery · 2025

DOI: 10.1016/j.jse.2024.12.015 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2025. Verfasst von Zachary DeVries und 8 weiteren Autor:innen. Beteiligte Einrichtung: Division of Orthopaedic Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada. Hauptthemen laut MEDLINE: Shoulder Joint, Arthroplasty, Replacement, Shoulder, Glenoid Cavity. Die Arbeit nennt 28 Literaturangaben. Gefördert von: Physicians' Services Inc Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Primary glenohumeral arthritis is typically associated with glenoid retroversion and posterior bone loss. Glenoid component fixation remains a weak link in the survivorship of anatomical total shoulder arthroplasty, particularly in the B2 glenoid. The aim of this study was to compare biomechanical properties of 2 glenoid preparation techniques in a B2 glenoid bone loss model. METHODS: This was a biomechanical cyclic loading study. Thirty sawbone shoulder models were generated from a computed tomography scan of a scapula with a B2 glenoid and 15° retroversion. The study consisted of 2 groups with 'low' correction (A groups), 2 groups with 'high' correction (B groups), and a control. Group A1 consisted of a 7° eccentric ream and a standard component; group A2 consisted of a 15° posteriorly augmented glenoid component (7° correction); group B1 consisted of a 12° anterior ream and standard component; group B2 used a 25° posteriorly augmented component (12° correction); group C (control) consisted of a standard component inserted in retroversion with no correction. Mechanical stability testing was performed through cyclic loading and resulting displacement was determined at 1, 10, 1000, 10,000, 50,000, and 100,000 cycles to assess for loosening. RESULTS: A total of 26 samples were included in the analysis, all reaching 100,000 cycles. Displacement increased significantly from baseline to 100,000 cycles in all groups (P < .05). At 100,000 cycles, the B1 group (1.4 mm ± 0.19) had significantly less displacement then the A2 (2.0 mm ± 0.29) and B2 (2.2 mm ± 0.49) (P = .0.005) groups. There were no significant differences in translational forces between any of the groups at 100,000 cycles. CONCLUSIONS: Our data demonstrated that the use of higher degree posteriorly augmented components resulted in statistically greater translational displacement over time compared with high-side reaming and use of a standard component. Further prospective clinical studies are needed to confirm these findings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Shoulder JointArthroplasty, Replacement, ShoulderGlenoid CavityHumansBiomechanical PhenomenaTomography, X-Ray ComputedScapula

Stichwörter der Autor:innen

Total shoulder arthroplastybiomechanicseccentric reamglenoid bone loselooseningposterior augment

Autor:innen und Institutionen

  • Division of Orthopaedic Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada.
  • Department of Mechanical and Aerospace Engineering, Carleton University, Ottawa, ON, Canada.
  • Division of Orthopaedic Surgery, The Ottawa Hospital, University of Ottawa, Ottawa, ON, Canada. Electronic address: plapner@toh.ca.

Förderung

  • Physicians&apos; Services Inc Foundation

Zitieren

APA

DeVries, Z., AlAhmed, R., Parisien, A., Nucci, N., Speirs, A., Walsh, K., Pollock, J. W., McIlquham, K., & Lapner, P. (2025). Eccentric reaming is superior to augmented components in B2 glenoids: a biomechanical study. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2024.12.015

Vancouver

DeVries Z, AlAhmed R, Parisien A, Nucci N, Speirs A, Walsh K, et al. Eccentric reaming is superior to augmented components in B2 glenoids: a biomechanical study. Journal of Shoulder and Elbow Surgery. 2025. doi:10.1016/j.jse.2024.12.015

BibTeX
@article{DeVries2025,
  author = {DeVries, Zachary and AlAhmed, Rashed and Parisien, Ariane and Nucci, Nicholas and Speirs, Andrew and Walsh, Kellen and Pollock, J Whitcomb and McIlquham, Katie and Lapner, Peter},
  title = {Eccentric reaming is superior to augmented components in B2 glenoids: a biomechanical study},
  journal = {Journal of Shoulder and Elbow Surgery},
  year = {2025},
  doi = {10.1016/j.jse.2024.12.015}
}