Both angled bony-increased offset and metal-augmented baseplates provide satisfactory bone incorporation to the glenoid in reverse total shoulder arthroplasty: a radiographic evaluation using tomosynthesis

Kazumasa Takayama, Hiromu Ito

Journal of Shoulder and Elbow Surgery · 2024

DOI: 10.1016/j.jse.2023.09.011 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Shoulder and Elbow Surgery, 2024. Verfasst von Kazumasa Takayama und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedics, Kurashiki Central Hospital, Okayama, Japan. Electronic address: kt13551@kchnet.or.jp. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Shoulder Joint, Glenoid Cavity, Shoulder Prosthesis. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 44 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Angled bony-increased offset and metal-augmented baseplate have recently been used to achieve neutral to inferior inclination of the glenoid implant. Nonetheless, bone incorporation is difficult to evaluate using computed tomography or other conventional methods owing to the presence of metal artifacts; therefore, whether bone incorporation between the grafted bone and glenoid or between the graft and baseplate implant can be achieved remains unclear. Several studies have reported the effectiveness of tomosynthesis in reducing metal artifacts for the evaluation of implant loosening, bone resorption, and spot welds. We aimed to evaluate and compare the bone incorporation rates between angled bony-increased offset and metal-augmented implants using tomosynthesis with metal artifact reduction technology. We hypothesized that a high bone incorporation rate would be obtained with angled bony-increased offset and a metal-augmented baseplate. METHODS: A total of 52 patients who underwent reverse total shoulder arthroplasty (TSA) with angled bony-increased offset and 42 patients who underwent reverse total shoulder arthroplasty with metal-augmented baseplate were assessed and followed up for a minimum of 2 years. The bone incorporation and implant loosening rates were compared between the 2 groups, and the sites of spot welds and trabeculation were recorded according to zones. Bone incorporation between the bone and prosthesis was defined as a confirmation of spot welds connecting the porous area and bone in more than three zones. Bone incorporation between the native bone and grafted bone was defined as an observation of trabeculation. Glenoid loosening was defined as the presence of at least 1 mm radiolucency around the prosthesis in more than 2 zones. RESULTS: Both the angled bony-increased offset and metal-augmented baseplate groups achieved sufficient bone incorporation rates (98% [51/52 cases] vs. 100% [42/42 cases], P = 1.0) and low implant loosening rates (2% [1/52 cases] vs. 0% [0/42 cases], P = 1.0). Spot welds and trabeculation were likely to be confirmed in the lower parts of the glenoid. CONCLUSION: The two groups did not show any significant differences regarding bone incorporation rates. Considering the complexity of performing the procedure with angled bony-increased offset, the use of a metal-augmented baseplate can serve as an alternative treatment to avoid superior inclination in reverse total shoulder arthroplasty.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Arthroplasty, Replacement, ShoulderShoulder JointGlenoid CavityShoulder ProsthesisHumansScapulaTomography, X-Ray ComputedRetrospective StudiesTreatment Outcome

Stichwörter der Autor:innen

Bone fusionbone incorporationbone integrationbony-increased offsetmetal artifactmetal augmentationtomosynthesis

Autor:innen und Institutionen

  • Department of Orthopaedics, Kurashiki Central Hospital, Okayama, Japan. Electronic address: kt13551@kchnet.or.jp.
  • Department of Orthopaedics, Kurashiki Central Hospital, Okayama, Japan.

Zitieren

APA

Takayama, K., & Ito, H. (2024). Both angled bony-increased offset and metal-augmented baseplates provide satisfactory bone incorporation to the glenoid in reverse total shoulder arthroplasty: a radiographic evaluation using tomosynthesis. Journal of Shoulder and Elbow Surgery. https://doi.org/10.1016/j.jse.2023.09.011

Vancouver

Takayama K, Ito H. Both angled bony-increased offset and metal-augmented baseplates provide satisfactory bone incorporation to the glenoid in reverse total shoulder arthroplasty: a radiographic evaluation using tomosynthesis. Journal of Shoulder and Elbow Surgery. 2024. doi:10.1016/j.jse.2023.09.011