Does glenoid inclination affect the anterior stability of reverse total shoulder arthroplasty? A biomechanical study
European Journal of Orthopaedic Surgery & Traumatology · 2024
DOI: 10.1007/s00590-024-03898-7 ↗Kurz gefasst
Fachartikel in der Zeitschrift European Journal of Orthopaedic Surgery & Traumatology, 2024. Verfasst von Marc-Frederic Pastor und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Städtisches Klinikum Braunschweig gGmbH, Holwedestraße 16, 38118, Braunschweig, Germany. Hauptthemen laut MEDLINE: Arthroplasty, Replacement, Shoulder, Shoulder Prosthesis, Shoulder Joint. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: DePuy Synthes, Medizinische Hochschule Hannover (MHH).
Abstract (Originalsprache)
Purpose
The anterior stability of reverse total shoulder arthroplasty is affected by multiple factors. However, the effect of glenosphere inclination on stability has rarely been investigated, which is what this study aims to look into.
Methods
Reverse shoulder arthroplasty was performed on 15 cadaveric human shoulders. The anterior dislocation forces and range of motion in internal rotation in the glenohumeral joint (primary measured parameters) were tested in a shoulder simulator in different arm positions and implant configurations, as well as with a custom-made 10° inferiorly inclined glenosphere. The inclination and retroversion of the baseplate as well as the distance between the glenoid and coracoid tip in two planes (secondary measured parameters) were evaluated on CT scans.
Results
In biomechanical testing, the custom-made inclined glenosphere showed no significant influence on anterior stability other than glenoid lateralisation over all arm positions as well as the neck-shaft angle in two arm positions. The 6 mm lateralised glenosphere reduced internal rotation at 30° and 60° of glenohumeral abduction. In 30° of glenohumeral abduction, joint stability was increased using the 155° epiphysis compared with the 145° epiphysis. The mean inclination was 16.1°. The inclination was positively, and the distance between the glenoid and coracoid tip in the anterior-to-posterior direction was negatively correlated with anterior dislocation forces.
Conclusions
The custom-made inferiorly inclined glenosphere did not influence anterior stability, but baseplate inclination itself had a significant effect on stability.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopaedic Surgery, Städtisches Klinikum Braunschweig gGmbH, Holwedestraße 16, 38118, Braunschweig, Germany.
- Department of Orthopaedic Surgery, DIAKOVERE Annastift, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, DIAKOVERE Annastift, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany. nebel.dennis@mh-hannover.de.
- Laboratory for Biomechanics and Biomaterials, Department of Orthopaedic Surgery, DIAKOVERE Annastift, Hannover Medical School, Anna-von-Borries-Str. 1-7, 30625, Hannover, Germany.
Förderung
- DePuy Synthes
- Medizinische Hochschule Hannover (MHH)
Zitieren
APA
Pastor, M. F., Nebel, D., Becker, L. M., Hurschler, C., Karrer, A. A., & Smith, T. (2024). Does glenoid inclination affect the anterior stability of reverse total shoulder arthroplasty? A biomechanical study. European Journal of Orthopaedic Surgery & Traumatology. https://doi.org/10.1007/s00590-024-03898-7
Vancouver
Pastor MF, Nebel D, Becker LM, Hurschler C, Karrer AA, Smith T. Does glenoid inclination affect the anterior stability of reverse total shoulder arthroplasty? A biomechanical study. European Journal of Orthopaedic Surgery & Traumatology. 2024. doi:10.1007/s00590-024-03898-7
BibTeX
@article{Pastor2024,
author = {Pastor, Marc-Frederic and Nebel, Dennis and Becker, Lennart Mathis and Hurschler, Christof and Karrer, Alba Aurora and Smith, Tomas},
title = {Does glenoid inclination affect the anterior stability of reverse total shoulder arthroplasty? A biomechanical study},
journal = {European Journal of Orthopaedic Surgery & Traumatology},
year = {2024},
doi = {10.1007/s00590-024-03898-7}
}
EUVIMED