EUVIMEDEUVIMED entdecken
Studienprotokoll

A practical protocol for high-spatial-resolution magnetic resonance angiography for cerebral arteries in rats

Hiroshi Nagahama, Masanori Sasaki, Katsuya Komatsu, Kaori Sato, Yoshimi Katagiri, Masaki Kamagata, Yuko Kataoka-Sasaki, Shinichi Oka, Ryo Ukai, Takahiro Yokoyama, Kojiro Terada, Masato Kobayashi und 2 weitere

Journal of Neuroscience Methods · 2023

DOI: 10.1016/j.jneumeth.2023.109784 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift Journal of Neuroscience Methods, 2023. Verfasst von Hiroshi Nagahama und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Neural Regenerative Medicine, Research Institute for Frontier Medicine, Sapporo Medical University School of Medicine, Sapporo 060-8556…. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Cerebrovascular Disorders. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: U.S. Department of Veterans Affairs, Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Magnetic resonance angiography (MRA) is an important tool in rat models of cerebrovascular disease. Although MRA has long been used in rodents, the image quality is typically not as high as that observed in clinical practice. Moreover, studies on MRA image quality in rats are limited. This study aimed to develop a practical high-spatial-resolution MRA protocol for imaging cerebral arteries in rats. NEW METHOD: We used the "half position method" regarding coil placement and modified the imaging parameters and image reconstruction method. We applied this new imaging method to measure maturation-related signal changes on rat MRAs. RESULTS: The new practical high-spatial-resolution MRA imaging protocol obtained a signal intensity up to 3.5 times that obtained using a basic coil system, simply by modifying the coil placement method. This method allowed the detection of a gradual decrease in the signal in cerebral vessels with maturation. COMPARISON WITH EXISTING METHODS: A high-spatial-resolution MRA for rats was obtained with an imaging time of approximately 100 min. Comparable resolution and image quality were obtained using the new protocol with an imaging time of 30 min CONCLUSIONS: The new practical high-spatial-resolution MRA protocol can be implemented simply and successfully to achieve high image quality with an imaging time of approximately 30 min. This protocol will benefit researchers performing MRA imaging in cerebral artery studies in rats.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance AngiographyCerebrovascular DisordersRatsAnimalsCerebral ArteriesImage Processing, Computer-AssistedImaging, Three-DimensionalCerebral AngiographyContrast Media

Stichwörter der Autor:innen

Cerebral arteryHigh-spatial-resolutionMagnetic resonance angiography

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Neural Regenerative Medicine, Research Institute for Frontier Medicine, Sapporo Medical University School of Medicine, Sapporo 060-8556, Japan; Division of Radioisotope Research, Biomedical Research, Educa…
  • Department of Neural Regenerative Medicine, Research Institute for Frontier Medicine, Sapporo Medical University School of Medicine, Sapporo 060-8556, Japan; Department of Neurology, Yale University School of Medicine,…
  • Department of Neurosurgery, Sapporo Medical University School of Medicine, Sapporo 060-8556, Japan.
  • Division of Radioisotope Research, Biomedical Research, Education and Instrumentation Center, Sapporo Medical University School of Medicine, Sapporo, Hokkaido 060-8556, Japan.
  • Department of Neural Regenerative Medicine, Research Institute for Frontier Medicine, Sapporo Medical University School of Medicine, Sapporo 060-8556, Japan.
  • Department of Neurology, Yale University School of Medicine, Neurology, PO BOX 208018, New Haven, CT 06510, USA; Department of Neuroscience, Yale University School of Medicine, Neurology, PO BOX 208018, New Haven, CT 06…

Förderung

  • U.S. Department of Veterans Affairs
  • Japan Society for the Promotion of Science

Zitieren

APA

Nagahama, H., Sasaki, M., Komatsu, K., Sato, K., Katagiri, Y., Kamagata, M., Kataoka-Sasaki, Y., Oka, S., Ukai, R., Yokoyama, T., Terada, K., Kobayashi, M., Kocsis, J. D., & Honmou, O. (2023). A practical protocol for high-spatial-resolution magnetic resonance angiography for cerebral arteries in rats. Journal of Neuroscience Methods. https://doi.org/10.1016/j.jneumeth.2023.109784

Vancouver

Nagahama H, Sasaki M, Komatsu K, Sato K, Katagiri Y, Kamagata M, et al. A practical protocol for high-spatial-resolution magnetic resonance angiography for cerebral arteries in rats. Journal of Neuroscience Methods. 2023. doi:10.1016/j.jneumeth.2023.109784

BibTeX
@article{Nagahama2023,
  author = {Nagahama, Hiroshi and Sasaki, Masanori and Komatsu, Katsuya and Sato, Kaori and Katagiri, Yoshimi and Kamagata, Masaki and Kataoka-Sasaki, Yuko and Oka, Shinichi and Ukai, Ryo and Yokoyama, Takahiro and Terada, Kojiro and Kobayashi, Masato and Kocsis, Jeffery D and Honmou, Osamu},
  title = {A practical protocol for high-spatial-resolution magnetic resonance angiography for cerebral arteries in rats},
  journal = {Journal of Neuroscience Methods},
  year = {2023},
  doi = {10.1016/j.jneumeth.2023.109784}
}
Kostenlos starten →