DynaTOF : Time‐Resolved Noncontrast Cerebral MR Angiography Using Spatially Modulated RF Saturation
Magnetic Resonance in Medicine · 2026-09 · 96 (3) · 1134-1147
DOI: 10.1002/mrm.70400 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 11.05.2026. Verfasst von Naoyuki Takei und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Intracranial Arteriovenous Malformations, Cerebral Angiography. Die Arbeit nennt 43 Literaturangaben.
Abstract (Originalsprache)
Purpose
To develop a time‐resolved extension of three‐dimensional time‐of‐flight MR angiography, termed Dynamic TOF (DynaTOF), that exploits intrinsic RF saturation behavior to enable noncontrast visualization of cerebrovascular hemodynamics.
Methods
DynaTOF was implemented by varying flip angle, repetition time (TR), and slab‐selective RF excitation profile to modulate longitudinal magnetization saturation and encode relative inflow timing. Data were acquired using a short‐TR protocol combined with deep‐learning reconstruction to ensure scan efficiency. Five healthy volunteers underwent DynaTOF and pulsed arterial spin labeling (PASL) MRA. Five patients with intracranial arteriovenous malformations (AVMs) were scanned to evaluate clinical feasibility and compare temporal patterns with digital subtraction angiography (DSA). Analyses included inflow‐time characterization, cross‐correlation with PASL, region‐of‐interest assessment of arterial, nidus, and venous structures, as well as apparent SNR and contrast‐to‐noise ratio (CNR) quantification.
Results
In healthy volunteers, DynaTOF exhibited predictable parameter‐dependent inflow behavior and qualitative agreement with PASL‐derived inversion‐time dynamics. Apparent arterial SNR and CNR maxima were slice‐position dependent, shifting from higher flip angles (20°–30°) at the slab entrance to lower angles (7°–15°) distally. In AVM patients, DynaTOF delineated arterial‐to‐nidus‐to‐early‐venous transitions consistent with DSA, while venous depiction was attenuated for horizontal or curved‐flow vessels due to the directional dependence of TOF‐based inflow contrast. Short‐TR acquisition with deep‐learning reconstruction enabled single‐slab imaging with a voxel size of 0.5 × 0.7 × 0.8 mm 3 in approximately 1 min, supporting flexible parameter sweeps within routine clinical time constraints.
Conclusion
DynaTOF offers a noninvasive approach for time‐resolved characterization of cerebrovascular flow while preserving TOF‐like spatial resolution.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan.
- GE HealthCare, Tokyo, Japan.
- Radiology Center, The University of Tokyo Hospital, Tokyo, Japan.
- GE HealthCare, Menlo Park, California, USA.
- Department of Neurosurgery, Faculty of Medicine, The University of Tokyo, Tokyo, Japan.
ORCID-Profile: Motoyuki Umekawa, Osamu Abe
Zitieren
APA
Takei, N., Fujii, K., Zhu, X., Suzuki, Y., Miyawaki, S., Umekawa, M., Koizumi, S., Wakayama, T., Amemiya, S., & Abe, O. (2026). DynaTOF : Time‐Resolved Noncontrast Cerebral MR Angiography Using Spatially Modulated RF Saturation. Magnetic Resonance in Medicine, 96(3), 1134-1147. https://doi.org/10.1002/mrm.70400
Vancouver
Takei N, Fujii K, Zhu X, Suzuki Y, Miyawaki S, Umekawa M, et al. DynaTOF : Time‐Resolved Noncontrast Cerebral MR Angiography Using Spatially Modulated RF Saturation. Magnetic Resonance in Medicine. 2026;96(3):1134-1147. doi:10.1002/mrm.70400
BibTeX
@article{Takei2026,
author = {Takei, Naoyuki and Fujii, Keita and Zhu, Xucheng and Suzuki, Yuichi and Miyawaki, Satoru and Umekawa, Motoyuki and Koizumi, Satoshi and Wakayama, Tetsuya and Amemiya, Shiori and Abe, Osamu},
title = {DynaTOF : Time‐Resolved Noncontrast Cerebral MR Angiography Using Spatially Modulated RF Saturation},
journal = {Magnetic Resonance in Medicine},
year = {2026},
volume = {96},
number = {3},
pages = {1134--1147},
doi = {10.1002/mrm.70400}
}
EUVIMED