EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Direct angiographic comparison of different velocity‐selective saturation, inversion, and DANTE labeling modules on cerebral arteries

Dapeng Liu iD, Dan Zhu iD, Qin Qin iD

Magnetic Resonance in Medicine · 2024

DOI: 10.1002/mrm.30085 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Magnetic Resonance in Medicine, 2024. Verfasst von Dapeng Liu und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA. Hauptthemen laut MEDLINE: Cerebral Arteries, Magnetic Resonance Angiography, Fourier Analysis. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 60 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIH HHS, NCI NIH HHS, NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This study evaluated the velocity‐selective (VS) MRA with different VS labeling modules, including double refocused hyperbolic tangent, eight‐segment B1‐insensitive rotation, delay alternating with nutation for tailored excitation, Fourier transform–based VS saturation, and Fourier transform–based inversion.

Methods

These five VS labeling modules were evaluated first through Bloch simulations, and then using VSMRA directly on various cerebral arteries of healthy subjects. The relative signal ratios from arterial ROIs and surrounding tissues as well as relative arteria‐tissue contrast ratios of different methods were compared.

Results

Double refocused hyperbolic tangent and eight‐segment B1‐insensitive rotation showed very similar labeling effects. Delay alternating with nutation for tailored excitation yielded high arterial signal but with residual tissue signal due to the spatial banding effect. Fourier transform–based VS saturation with half the time of other techniques serves as an efficient nonsubtractive VSMRA method, but the remaining tissue signal still obscured some small distal arteries that were delineated by other subtraction‐based VSMRA, allowing more complete cancelation of static tissue. Fourier transform–based inversion produced the highest arterial signal in VSMRA with minimal tissue background.

Conclusion

This is the first study that angiographically compared five different VS labeling modules. Their labeling characteristics on arteries and tissue and implications for VSMRA and VS arterial spin labeling are discussed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cerebral ArteriesMagnetic Resonance AngiographyFourier AnalysisHumansAdultMaleFemaleAlgorithmsBlood Flow VelocitySpin LabelsCerebral AngiographyCerebrovascular CirculationImage Processing, Computer-AssistedImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

DANTEvelocity‐selective MR angiographyvelocity‐selective arterial spin labelingvelocity‐selective inversionvelocity‐selective saturation

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
  • F.M. Kirby Research Center for Functional Brain Imaging, Kennedy Krieger Institute, Baltimore, Maryland, USA.

ORCID-Profile: Dapeng Liu, Dan Zhu, Qin Qin

Förderung

  • NIH HHS
  • NCI NIH HHS
  • NHLBI NIH HHS
  • NIA NIH HHS
  • NIH

Zitieren

APA

Liu, D., Zhu, D., & Qin, Q. (2024). Direct angiographic comparison of different velocity‐selective saturation, inversion, and DANTE labeling modules on cerebral arteries. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.30085

Vancouver

Liu D, Zhu D, Qin Q. Direct angiographic comparison of different velocity‐selective saturation, inversion, and DANTE labeling modules on cerebral arteries. Magnetic Resonance in Medicine. 2024. doi:10.1002/mrm.30085

BibTeX
@article{Liu2024,
  author = {Liu, Dapeng and Zhu, Dan and Qin, Qin},
  title = {Direct angiographic comparison of different velocity‐selective saturation, inversion, and DANTE labeling modules on cerebral arteries},
  journal = {Magnetic Resonance in Medicine},
  year = {2024},
  doi = {10.1002/mrm.30085}
}
Kostenlos starten →