EUVIMEDEUVIMED entdecken
Open Access

Simultaneous Intracranial Angiography and Susceptibility Imaging ( SIAS ) by Combining Velocity‐Selective ASL and Multi‐Echo SWI

Lixin Liu iD, Ying-Hua Chu, Lili Wang iD, Jian Wang, Yujun Liao, Bin Xu, Hao Li iD, He Wang, Zhensen Chen iD

Magnetic Resonance in Medicine · 2026-10 · 96 (4) · 1589-1604

DOI: 10.1002/mrm.70441 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, online erschienen am 24.05.2026. Verfasst von Lixin Liu und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China. Hauptthemen laut MEDLINE: Magnetic Resonance Angiography, Cerebral Angiography, Brain, Image Processing, Computer-Assisted. Die Arbeit nennt 37 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Natural Science Foundation of Shanghai Municipality.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Intracranial angiography and susceptibility imaging are two important modalities for assessment of cerebral disorders. This study aims to develop a simultaneous intracranial angiography and susceptibility imaging (SIAS) sequence with high acquisition efficiency and good visibility of distal cerebral vessels.

Methods

SIAS embeds multi‐echo susceptibility‐weighted imaging (SWI) within the velocity‐selective arterial spin labeling (VSASL) MRA. Sequence parameters, including lines per shot (LPS) and SWI flip angle (FA), were optimized in healthy volunteers. Mutual influence between VSASL and SWI acquisition was also evaluated. SIAS was then compared with conventional VSASL, TOF, and SWI. Quantitative metrics included arterial length, sharpness and intensity; vein sharpness; and susceptibility values. Artery–vein separation in SIAS‐VSASL was performed using a susceptibility‐guided strategy.

Results

Lower LPS improved distal vessel depiction but reduced carotid siphon visibility in both conventional VSASL and SIAS‐VSASL. A centric‐in SWI readout enhanced vein sharpness and yielded better visualization of proximal arteries. Increasing SWI FA also improved vein sharpness but reduced vessel length. SIAS‐VSASL visualized distal artery better than TOF, and improved proximal artery sharpness over VSASL. SIAS‐SWI yielded sharper vein depiction and reliable susceptibility quantification. The proposed susceptibility‐guided post‐processing enabled effective artery–vein separation in SIAS‐VSASL.

Conclusion

SIAS provides good visualization of small arteries while supporting hemorrhage detection, quantitative susceptibility mapping reconstruction, and venous imaging, which facilitate artery–vein separation in SIAS‐VSASL. It demonstrates strong potential for comprehensive assessment of brain disorders.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Magnetic Resonance AngiographyCerebral AngiographyBrainImage Processing, Computer-AssistedMagnetic Resonance ImagingHumansMaleAdultFemaleSpin LabelsCerebral ArteriesCerebrovascular CirculationAlgorithmsHealthy VolunteersImage Interpretation, Computer-Assisted

Stichwörter der Autor:innen

cerebrovascular imagingmagnetic resonance angiographyquantitative susceptibility mappingsusceptibility‐weighted imagingvelocity‐selective arterial spin labeling

Substanzen

Spin Labels

Autor:innen und Institutionen

  • Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, China.
  • MR Research Collaboration Team, Siemens Healthineers Ltd, Shanghai, China.
  • Department of Neurosurgery, The Second People's Hospital of Changzhou, the Third Affiliated Hospital of Nanjing Medical University, Changzhou Medical Center, Changzhou, China.
  • Department of Neurosurgery, Fudan University Huashan Hospital, Shanghai, China.
  • Clinical Medical Center of Neurosurgery, Shanghai Key Laboratory of Brain Function and Restoration and Neural Regeneration, Shanghai, China.
  • Key Laboratory of Computational Neuroscience and Brain-Inspired Intelligence (Fudan University), Ministry of Education, Shanghai, China.

ORCID-Profile: Lixin Liu, Lili Wang, Hao Li, Zhensen Chen

Förderung

  • National Key Research and Development Program of China
  • National Natural Science Foundation of China
  • Natural Science Foundation of Shanghai Municipality
  • Changzhou Health Commission Major Science and Technology Project
  • Changzhou Sci & Tech Program
  • Clinical Program of Changzhou Medical Center

Zitieren

APA

Liu, L., Chu, Y. H., Wang, L., Wang, J., Liao, Y., Xu, B., Li, H., Wang, H., & Chen, Z. (2026). Simultaneous Intracranial Angiography and Susceptibility Imaging ( SIAS ) by Combining Velocity‐Selective ASL and Multi‐Echo SWI. Magnetic Resonance in Medicine, 96(4), 1589-1604. https://doi.org/10.1002/mrm.70441

Vancouver

Liu L, Chu YH, Wang L, Wang J, Liao Y, Xu B, et al. Simultaneous Intracranial Angiography and Susceptibility Imaging ( SIAS ) by Combining Velocity‐Selective ASL and Multi‐Echo SWI. Magnetic Resonance in Medicine. 2026;96(4):1589-1604. doi:10.1002/mrm.70441

BibTeX
@article{Liu2026,
  author = {Liu, Lixin and Chu, Ying-Hua and Wang, Lili and Wang, Jian and Liao, Yujun and Xu, Bin and Li, Hao and Wang, He and Chen, Zhensen},
  title = {Simultaneous Intracranial Angiography and Susceptibility Imaging ( SIAS ) by Combining Velocity‐Selective ASL and Multi‐Echo SWI},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  volume = {96},
  number = {4},
  pages = {1589--1604},
  doi = {10.1002/mrm.70441}
}
Kostenlos starten →