Evaluation of wear, corrosion, and biocompatibility of a novel biomedical TiZr-based medium entropy alloy

Dandan Zhu, Xiaoqiang Li, Shaoyu Chai, Tien-Shee Chee, Chaerin Kim, Liang Li, Dexue Liu

Journal of the Mechanical Behavior of Biomedical Materials · 2025

DOI: 10.1016/j.jmbbm.2025.106951 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Mechanical Behavior of Biomedical Materials, 2025. Verfasst von Dandan Zhu und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Materials Science and Engineering, Lanzhou University of Technology, Lanzhou, 730050, China; State Key Laboratory of Advanced Processing an…. Hauptthemen laut MEDLINE: Alloys, Materials Testing, Biocompatible Materials, Entropy. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: Foundation for Innovation Groups of Basic Research in Gansu Province, Major Science and Technology Project of Hainan Province, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

As a promising material for medical implants, the Ti40Zr40Nb5Ta12Sn3 medium entropy alloy (MEA) shows potential for biomedical applications. This study investigates its wear and corrosion behavior in simulated biological environments, including artificial saliva (AS), simulated blood (SB), and simulated body fluid (SBF). Electrochemical tests revealed excellent corrosion resistance in AS solution, with a higher corrosion potential (-0.31420 V) and a lower corrosion current density (2.613 × 10⁻⁷ A·cm⁻2). Wear tests showed that friction coefficients ranked as μAS > μSBF > μSB, while wear rates followed δSBF > δSB > δAS, highlighting the impact of bio-lubricants composition on tribological behavior. In particular, the alloy exhibited a higher ion release rate in the SBF solution, with ion concentrations approximately 2.5 times greater than those in the AS solution. In contrast, the alloy in the AS solution maintained a more stable passivation film, thus reducing ion release and enhancing both wear and corrosion resistance of the alloy. The biocompatibility test further confirmed that it has good cell adhesion and proliferation ability. This study provides valuable insights into the synergistic effects of wear and corrosion on the alloy in simulated physiological environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlloysMaterials TestingBiocompatible MaterialsEntropyTitaniumZirconiumCorrosionAnimalsMiceCell ProliferationCell AdhesionFrictionSaliva, ArtificialBody Fluids

Stichwörter der Autor:innen

BiomaterialsCorrosionIon releaseMedium entropy alloyWear

Substanzen

AlloysBiocompatible MaterialsTitaniumZirconiumSaliva, Artificial

Autor:innen und Institutionen

  • School of Materials Science and Engineering, Lanzhou University of Technology, Lanzhou, 730050, China; State Key Laboratory of Advanced Processing and Recycling of Non-ferrous Metals, Lanzhou University of Technology, L…
  • School of Materials Science and Engineering, Lanzhou University of Technology, Lanzhou, 730050, China.
  • Department of Materials Science and Engineering, KAIST, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • Department of Nuclear and Quantum Engineering, KAIST, Yuseong-gu, Daejeon, 34141, Republic of Korea.
  • School of Materials Science and Engineering, Lanzhou University of Technology, Lanzhou, 730050, China; Xi'an Shiyou University, School of Materials Science and Engineering, Xian 710065, China. Electronic address: dxliu@…

Förderung

  • Foundation for Innovation Groups of Basic Research in Gansu Province
  • Major Science and Technology Project of Hainan Province
  • National Natural Science Foundation of China
  • Lanzhou University of Technology

Zitieren

APA

Zhu, D., Li, X., Chai, S., Chee, T. S., Kim, C., Li, L., & Liu, D. (2025). Evaluation of wear, corrosion, and biocompatibility of a novel biomedical TiZr-based medium entropy alloy. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2025.106951

Vancouver

Zhu D, Li X, Chai S, Chee TS, Kim C, Li L, et al. Evaluation of wear, corrosion, and biocompatibility of a novel biomedical TiZr-based medium entropy alloy. Journal of the Mechanical Behavior of Biomedical Materials. 2025. doi:10.1016/j.jmbbm.2025.106951

BibTeX
@article{Zhu2025,
  author = {Zhu, Dandan and Li, Xiaoqiang and Chai, Shaoyu and Chee, Tien-Shee and Kim, Chaerin and Li, Liang and Liu, Dexue},
  title = {Evaluation of wear, corrosion, and biocompatibility of a novel biomedical TiZr-based medium entropy alloy},
  journal = {Journal of the Mechanical Behavior of Biomedical Materials},
  year = {2025},
  doi = {10.1016/j.jmbbm.2025.106951}
}
Kostenlos starten →