EUVIMEDEUVIMED entdecken
Crossref

Si-modified beta-Ti–25Mo biomaterials with reduced elastic modulus, enhanced corrosion resistance, and cytocompatibility

Krishan Kumar iD, Mohit Kamboj iD, Bodhisatwa Das iD, Harpreet Singh, Khushboo Rakha iD

Biomedical Physics & Engineering Express · 01.08.2026 · 12 (4) · 045032

DOI: 10.1088/2057-1976/ae86fa ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biomedical Physics & Engineering Express, online erschienen am 21.07.2026. Verfasst von Krishan Kumar und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Metallurgical and Materials Engineering, Indian Institute of Technology Ropar, Rupnagar, Punjab 140001, India. Hauptthemen laut MEDLINE: Elastic Modulus, Biocompatible Materials, Titanium, Alloys. Die Arbeit nennt 48 Literaturangaben. Gefördert von: CSIR.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

One of the key challenges for β -Ti alloys in biomedical applications is achieving a balance among low elastic modulus, high corrosion resistance, and cytocompatibility. In this study, Ti25MoxSi alloys ( x = 0–2 wt.%) were designed to ensure a metastable β- phase. The alloys were fabricated using vacuum arc melting. Their microstructures and surfaces were evaluated by optical microscopy and XRD to assess the constituting phases. The elastic modulus and hardness of the alloys were evaluated using nanoindentation. The corrosion behavior in aerated Ringer’s solution using Electrochemical analysis. SEM, MTT assay, and live/dead cell assay were used to examine the in vitro biological responses of all alloys. Optical microscopy shows equiaxed β- Ti grains in all alloys, with ultrafine silicide precipitates at grain boundaries in 1.5 and 2 wt.% Si content. XRD analysis reveals stable β -phase for all alloys. The nanoindentation studies show a reduced elastic modulus of 80–85 GPa. A significant enhancement in hardness was observed with typical values around 4 GPa. Preliminary electrochemical studies show improved corrosion resistance, suggesting the formation of a passive film upon adding Silicon. In vitro studies using MC3T3-E1 cells confirm cytocompatibility across all compositions. The study highlights the potential of Ti–Mo–Si alloys for load-bearing biomedical implants.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Elastic ModulusBiocompatible MaterialsTitaniumAlloysSiliconMolybdenumCorrosionMaterials TestingAnimalsMiceHardnessX-Ray DiffractionCell LineSurface PropertiesCell Survival

Stichwörter der Autor:innen

Ti–Mo–Si alloysbioactivebiocorrosionbiomedical alloyscytocompatible

Substanzen

Biocompatible MaterialsTitaniumAlloysSiliconMolybdenumbeta titanium

Autor:innen und Institutionen

  • Department of Metallurgical and Materials Engineering, Indian Institute of Technology Ropar, Rupnagar, Punjab 140001, India.
  • Department of Biomedical Engineering, Indian Institute of Technology Ropar, Rupnagar, Punjab 140001, India.
  • Department of Mechanical Engineering, Indian Institute of Technology Ropar, Rupnagar, Punjab 140001, India.

ORCID-Profile: Krishan Kumar, Mohit Kamboj, Bodhisatwa Das, Khushboo Rakha

Förderung

  • CSIR

Zitieren

APA

Kumar, K., Kamboj, M., Das, B., Singh, H., & Rakha, K. (2026). Si-modified beta-Ti–25Mo biomaterials with reduced elastic modulus, enhanced corrosion resistance, and cytocompatibility. Biomedical Physics & Engineering Express, 12(4), 045032. https://doi.org/10.1088/2057-1976/ae86fa

Vancouver

Kumar K, Kamboj M, Das B, Singh H, Rakha K. Si-modified beta-Ti–25Mo biomaterials with reduced elastic modulus, enhanced corrosion resistance, and cytocompatibility. Biomedical Physics & Engineering Express. 2026;12(4):045032. doi:10.1088/2057-1976/ae86fa

BibTeX
@article{Kumar2026,
  author = {Kumar, Krishan and Kamboj, Mohit and Das, Bodhisatwa and Singh, Harpreet and Rakha, Khushboo},
  title = {Si-modified beta-Ti–25Mo biomaterials with reduced elastic modulus, enhanced corrosion resistance, and cytocompatibility},
  journal = {Biomedical Physics & Engineering Express},
  year = {2026},
  volume = {12},
  number = {4},
  pages = {045032},
  doi = {10.1088/2057-1976/ae86fa}
}