Trueness of intraoral scanning for different tooth-size arch-length deficiencies
Journal of Dental Sciences · 2024-01 · 19 (1) · 397-403
DOI: 10.1016/j.jds.2023.08.006 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Dental Sciences, 2024-01. Verfasst von Wei-Qi Lin und 5 weiteren Autor:innen. Beteiligte Einrichtung: School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: National Science and Technology Council.
Abstract (Originalsprache)
Background/purpose: As science and technology continue to advance, the utilization of intraoral scanners (IOSs) has become increasingly popular in the orthodontic workflow. The aim of this study was to discuss whether the degree of crowded arches affects scan accuracy. Materials and methods: Three different crowding levels of dental models (model MI: mild, model MO: moderate, and model SE: severe) were scanned using both an IOS and desktop scanner. Stereolithographic files were obtained and superimposed via CAD software to calculate differences between each measuring point of a model and the farthest corresponding point. The deviations from three models were compared with statistical analysis.
Results
The trueness of different crowding arches showed that the deviation value of model SE was the maximum, followed by model MI, and model MO in the maxillary arch. In the mandibular arch, the order of the deviation from greatest to least was firstly model SE, then model MO, and model MI. Significant differences were observed among the maxillary models (P < 0.001), but there was no significant difference between models in the mandible (P = 0.669).
Conclusion
The trueness of the three crowded arches is in the clinically acceptable range. The degree of crowding increases, the trueness of scanning at each position decreases. In the maxillary arch, more severe crowding corresponds to higher deviations. In the mandible, the degree of crowding is not explicitly related to the maximum deviation; therefore, the clinician should notice the deviation when using IOSs for crowding cases.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan.
- Division of Orthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan.
- Department of Dentistry, Kaohsiung Municipal Siaogang Hospital, Kaohsiung, Taiwan.
- Division of Prosthodontics, Department of Dentistry, Kaohsiung Medical University Hospital, Kaohsiung, Taiwan.
Förderung
- National Science and Technology Council
Zitieren
APA
Lin, W. Q., Pan, C. Y., Chen, P. H., Liu, C. T., Hung, C. C., & Lan, T. H. (2024). Trueness of intraoral scanning for different tooth-size arch-length deficiencies. Journal of Dental Sciences, 19(1), 397-403. https://doi.org/10.1016/j.jds.2023.08.006
Vancouver
Lin WQ, Pan CY, Chen PH, Liu CT, Hung CC, Lan TH. Trueness of intraoral scanning for different tooth-size arch-length deficiencies. Journal of Dental Sciences. 2024;19(1):397-403. doi:10.1016/j.jds.2023.08.006
BibTeX
@article{Lin2024,
author = {Lin, Wei-Qi and Pan, Chin-Yun and Chen, Ping-Ho and Liu, Chih-Te and Hung, Chun-Cheng and Lan, Ting-Hsun},
title = {Trueness of intraoral scanning for different tooth-size arch-length deficiencies},
journal = {Journal of Dental Sciences},
year = {2024},
volume = {19},
number = {1},
pages = {397--403},
doi = {10.1016/j.jds.2023.08.006}
}