EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Trueness and scanning time of complete‐arch intraoral scans of edentulous arches with implants under different moisture conditions: Effects of splinting‐aid, scan body height, and scanner

Cecília Santos Galvão, Fabiana Silveira Ramalho Moreira, Annie Karoline Bezerra de Medeiros iD, Gabriela Panca Sabatini, Burak Yilmaz iD, Adriana da Fonte Porto Carreiro iD

Journal of Prosthodontics · 28.07.2026

DOI: 10.1111/jopr.70204 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Prosthodontics, online erschienen am 28.07.2026. Verfasst von Cecília Santos Galvão und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This in vitro study evaluated the influence of the presence of saliva in varying levels on the trueness and scanning time of complete‐arch intraoral scans for implant‐supported prostheses, considering different scan body heights, splinting protocols, and scanners. Materials and Methods A three‐dimensionally (3D)‐printed edentulous maxillary model with six implants and multi‐unit abutments was digitized using a metrology‐grade industrial scanner (Artec Micro), using polyetheretherketone scan bodies (ISBs) of two heights (short: 4.5 mm and tall: 8.0 mm). The model was also scanned with three intraoral scanners (IOSs) (TRIOS 5 [TR], NeoScan 1000 [NS], and Primescan [PS]) under two splinting wire aids (splinted and non‐splinted) and dry or artificial saliva‐moisturized (lightly or highly) conditions. A total of 192 scans ( n = 8 per experimental condition) were analyzed. Scanning time was recorded with a stopwatch, and trueness was analyzed as root mean square (RMS) deviation when industrial and IOS scans were aligned using Geomagic Control X. Data were analyzed with Kruskal–Wallis, Mann–Whitney U , and Bonferroni‐adjusted pairwise comparisons ( α = 0.05).

Results

Saliva significantly affected trueness and scan time, with higher moisture levels resulting in greater deviations ( p < 0.001) and longer acquisition times for all tested IOSs ( p < 0.001). IOS type, ISB height, and scan‐aid also had significant effects on scan trueness ( p < 0.001). TR presented the lowest RMS values, followed by PS and NS. Under moisture conditions, short ISBs and non‐splinted configurations produced more reliable scans ( p < 0.001). Short ISBs consistently reduced total scanning time compared with tall ISBs ( p < 0.001). PS demonstrated the shortest scanning times under dry and highly moisturized conditions, whereas NS combined with short ISBs showed the fastest acquisition under light moisture conditions.

Conclusion

The simulation of intraoral saliva presence compromised scan trueness, particularly when moisture level increased. Clinically, minimizing saliva presence during scans and selecting appropriate‐height ISBs can enhance trueness for digital implant scans. Although scan‐aid may reduce scanning time, its use should be limited to situations in which stabilization is critical, such as long edentulous arches or long interimplant distances, as these conditions may increase optical deviations in the presence of saliva. These findings support the refinement of clinical protocols for complete‐arch implant scans, emphasizing saliva control and careful scan strategy selection to improve trueness of digital edentulous scans.

Schlagwörter

Stichwörter der Autor:innen

complete‐arch intraoral scansedentulous archesscanning timetrueness

Autor:innen und Institutionen

  • Department of Dentistry, Federal University of Rio Grande do Norte (UFRN), Natal, Rio Grande do Norte, Brazil.
  • Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
  • Department of Prosthodontics, School of Dentistry, University of São Paulo (USP), São Paulo, Brazil.
  • Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland.
  • Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio, USA.

ORCID-Profile: Annie Karoline Bezerra de Medeiros, Burak Yilmaz, Adriana da Fonte Porto Carreiro

Zitieren

APA

Galvão, C. S., Moreira, F. S. R., de Medeiros, A. K. B., Sabatini, G. P., Yilmaz, B., & Carreiro, A. D. F. P. (2026). Trueness and scanning time of complete‐arch intraoral scans of edentulous arches with implants under different moisture conditions: Effects of splinting‐aid, scan body height, and scanner. Journal of Prosthodontics. https://doi.org/10.1111/jopr.70204

Vancouver

Galvão CS, Moreira FSR, de Medeiros AKB, Sabatini GP, Yilmaz B, Carreiro ADFP. Trueness and scanning time of complete‐arch intraoral scans of edentulous arches with implants under different moisture conditions: Effects of splinting‐aid, scan body height, and scanner. Journal of Prosthodontics. 2026. doi:10.1111/jopr.70204

BibTeX
@article{Galvo2026,
  author = {Galvão, Cecília Santos and Moreira, Fabiana Silveira Ramalho and de Medeiros, Annie Karoline Bezerra and Sabatini, Gabriela Panca and Yilmaz, Burak and Carreiro, Adriana da Fonte Porto},
  title = {Trueness and scanning time of complete‐arch intraoral scans of edentulous arches with implants under different moisture conditions: Effects of splinting‐aid, scan body height, and scanner},
  journal = {Journal of Prosthodontics},
  year = {2026},
  doi = {10.1111/jopr.70204}
}
Kostenlos starten →