EUVIMEDEUVIMED entdecken
Crossref

Patient Size Estimation Methods for CMS Size-Adjusted Dose Reporting: Variability, Challenges, and Recommendations

Gary Ge, Charles M Weaver, Alexander Alsalihi, Jie Zhang

Journal of the American College of Radiology · 2025

DOI: 10.1016/j.jacr.2025.07.021 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American College of Radiology, 2025. Verfasst von Gary Ge und 3 weiteren Autor:innen. Beteiligte Einrichtung: Division of Diagnostic & Nuclear Medical Physics, Department of Radiology, University of Kentucky College of Medicine, Lexington, Kentucky. Electroni…. Hauptthemen laut MEDLINE: Radiation Dosage, Tomography, X-Ray Computed, Body Size. Die Arbeit nennt 8 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: The new CMS1074v3 measure assesses CT size-adjusted dose (SAD) and image quality as part of a reimbursement-linked quality measure. However, a key calculation, patient size estimation, is not strictly defined by CMS, introducing variability that may compromise consistency. This study evaluates five methods for calculating patient size and their impact on SAD and compliance. METHODS: A retrospective analysis of 719 CT examinations across seven CT protocols was performed. These included five abdomen and two chest protocols covering various CT categories based on University of California San Francisco examples cited in the CMS measure. Five methods for calculating patient diameter were evaluated: Hounsfield unit (HU) Value Thresholding, Water-Equivalent Diameter (WED), Lateral (LAT) or anterior-posterior (AP) Conversion, LAT×AP, and (LAT + AP)/2. Statistical differences were assessed using Kruskal-Wallis and pairwise tests. RESULTS: SAD values demonstrate significant variability between calculation methods. Attenuation-based methods (HU threshold, WED) overestimated SAD in chest examinations, and projection-based methods showed greater variability in abdominal examinations. This variability affects compliance with CMS-defined dose thresholds, with attenuation-based methods resulting in more failures in chest examinations and projection-based methods in abdominal examinations. The Urogram protocol had SAD values >30% below CMS thresholds despite its high-dose category, suggesting potential error in classification or threshold value. Statistically significant differences (P < .05) were found in Chest pulmonary embolism, Chest without, and Urogram protocols. CONCLUSIONS: Inconsistencies in SAD estimation methods and protocol mapping pose technical challenges that compromise the effectiveness of the metric. Standardized examination mapping and revisiting dose thresholds may improve alignment with clinical practice and enhance the reliability of the CMS measure.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageTomography, X-Ray ComputedBody SizeHumansRetrospective StudiesUnited StatesCenters for Medicare and Medicaid Services, U.S.FemaleMale

Stichwörter der Autor:innen

CMSCT doseIQRsize-adjusted dose

Autor:innen und Institutionen

  • Division of Diagnostic & Nuclear Medical Physics, Department of Radiology, University of Kentucky College of Medicine, Lexington, Kentucky. Electronic address: gary.ge@uky.edu.
  • Division of Diagnostic & Nuclear Medical Physics, Department of Radiology, University of Kentucky College of Medicine, Lexington, Kentucky.
  • Chief, Division of Diagnostic & Nuclear Medical Physics, Department of Radiology, University of Kentucky College of Medicine, Lexington, Kentucky.

Zitieren

APA

Ge, G., Weaver, C. M., Alsalihi, A., & Zhang, J. (2025). Patient Size Estimation Methods for CMS Size-Adjusted Dose Reporting: Variability, Challenges, and Recommendations. Journal of the American College of Radiology. https://doi.org/10.1016/j.jacr.2025.07.021

Vancouver

Ge G, Weaver CM, Alsalihi A, Zhang J. Patient Size Estimation Methods for CMS Size-Adjusted Dose Reporting: Variability, Challenges, and Recommendations. Journal of the American College of Radiology. 2025. doi:10.1016/j.jacr.2025.07.021

BibTeX
@article{Ge2025,
  author = {Ge, Gary and Weaver, Charles M and Alsalihi, Alexander and Zhang, Jie},
  title = {Patient Size Estimation Methods for CMS Size-Adjusted Dose Reporting: Variability, Challenges, and Recommendations},
  journal = {Journal of the American College of Radiology},
  year = {2025},
  doi = {10.1016/j.jacr.2025.07.021}
}
Kostenlos starten →