Radiation dose assessment of pediatric computed tomography of the chest: the need to consider patient size
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncae212 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Vanessa Döwich und 6 weiteren Autor:innen. Beteiligte Einrichtung: Radiology Service, Hospital de Clínicas de Porto Alegre, Ramiro Barcelos, 2350 Bloco A, Av. Protásio Alves, 211 - Bloco B e C - Santa Cecília, Porto …. Hauptthemen laut MEDLINE: Radiation Dosage, Tomography, X-Ray Computed, Radiography, Thoracic. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
Objective
To evaluate the radiation dose of chest computed tomography (CT) examinations of pediatric patients and the extent to which volume CT dose index (CTDIvol) underestimates radiation dose in comparison to size specific dose estimates (SSDE).
Methods
Single-center, retrospective study of consecutive unenhanced pediatric (age <18 years) chest CTs between October 2015 and October 2016. Radiation dose as well as demographic and clinical data were recorded from 133 chest CTs. Patients were grouped into 4 categories based on mean effective diameter of the chest. SSDE was generated for each patient according to the water equivalent and effective diameter and compared to CTDIvol. Factors associated with higher radiation doses were assessed.
Results
CTDIvol underestimated radiation dose by 54.7%, 47.6%, 40.2%, and 31.2% (P < .001) for effective diameter groups 1 to 4, respectively, when compared to SSDE (calculated according to the water equivalent). When calculated according to the effective diameter, CTDIvol underestimated radiation dose by 47.6%, 39.4%, 27%, and 12.3% (P < .001) for effective diameter groups 1 to 4, respectively, when compared to SSDE. CT dose parameters, age, weight, Dw, and mean effective diameter were variables associated with higher radiation doses.
Conclusion
CTDIvol systematically underestimated radiation dose in comparison to SSDE in pediatric patients submitted to chest CT and should not be used as the primary parameter to monitor CT protocols in these patients. SSDE calculated according to effective diameter also underestimates the radiation dose compared to SSDE calculated based on water equivalent.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Radiology Service, Hospital de Clínicas de Porto Alegre, Ramiro Barcelos, 2350 Bloco A, Av. Protásio Alves, 211 - Bloco B e C - Santa Cecília, Porto Alegre - RS, 90035-903, Brazil.
- Department of Medical Imaging, University of Toronto. Endereço: 585 University Avenue, 1 PMB 274, Toronto, ON M5G 2N2, Canada.
- Medical Physics and Radioprotection Department, Hospital de Clínicas de Porto Alegre. Ramiro Barcelos, 2350 Bloco A, Av. Protásio Alves, 211 - Bloco B e C - Santa Cecília, Porto Alegre, RS 90035-903, Brazil.
- Faculty of Medicine, Universidade Federal do Rio Grande do Sul. Ramiro Barcelos, 2400 - Santa Cecília, Porto Alegre, RS 90035-003, Brazil.
- Programa de Pós-Graduação em Saúde da Criança e do Adolescente, Universidade Federal do Rio Grande do Sul. Ramiro Barcelos, 2400 - Santa Cecília, Porto Alegre, RS 90035-003, Brazil.
- Department of Pediatrics, Faculty of Medicine, Universidade Federal do Rio Grande do Sul. Ramiro Barcelos, 2400 - Santa Cecília, Porto Alegre, RS 90035-003, Brazil.
ORCID-Profile: Vanessa Döwich, Felipe Soares Torres, Maurício Anés
Zitieren
APA
Döwich, V., Torres, F. S., Nietto, A. L., Timm, V. S., Anés, M., Bacelar, A., & Maróstica, P. J. C. (2024). Radiation dose assessment of pediatric computed tomography of the chest: the need to consider patient size. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae212
Vancouver
Döwich V, Torres FS, Nietto AL, Timm VS, Anés M, Bacelar A, et al. Radiation dose assessment of pediatric computed tomography of the chest: the need to consider patient size. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae212
BibTeX
@article{Dwich2024,
author = {Döwich, Vanessa and Torres, Felipe Soares and Nietto, Andressa Lima and Timm, Vitor Silva and Anés, Maurício and Bacelar, Alexandre and Maróstica, Paulo José Cauduro},
title = {Radiation dose assessment of pediatric computed tomography of the chest: the need to consider patient size},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncae212}
}
EUVIMED