The Quasi-Adiabatic Graphite Calorimeter for Absolute Dosimetry in Ultrahigh Dose Rate FLASH X-Ray Radiation Therapy
International Journal of Radiation Oncology*Biology*Physics · 2026-10 · 126 (2) · 568-578
DOI: 10.1016/j.ijrobp.2026.03.028 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Radiation Oncology*Biology*Physics, 2026-10. Verfasst von Ji Huang und 13 weiteren Autor:innen. Beteiligte Einrichtung: Division of Ionizing Radiation Metrology, National Institute of Metrology (NIM), Beijing, China. Hauptthemen laut MEDLINE: Graphite, Calorimetry, Radiometry, Radiotherapy, High-Energy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
PURPOSE: FLASH radiation therapy using high-energy x rays combines ultrahigh dose rate irradiation with the physical characteristics of high-energy x-ray beams, achieving a significant reduction in normal tissue biological damage while maintaining sufficient tissue penetration, thereby presenting great potential for clinical translation. However, the absence of a traceable absolute dosimetry method for FLASH x-ray beams remains a substantial limitation to its clinical implementation. This study aims to establish a quasi-adiabatic water-controlled probe-type graphite calorimeter for the absolute measurement of absorbed dose to water in the 10 MV FLASH x-ray beam, to address the current lack of a traceable dosimetry standard for x-ray FLASH radiation therapy. METHODS AND MATERIALS: A probe-type graphite calorimeter was developed, employing thermally stabilized water as the thermal control medium to precisely regulate the thermal equilibrium of the graphite core. This quasi-adiabatic system is designed to facilitate accurate absolute dose measurements under ultrahigh dose rate conditions. RESULTS: The results indicate that for a single irradiation with a total dose exceeding 2 Gy, the mean type A relative uncertainty, determined from 5 repeated measurements using the sample standard deviation, is less than 0.2%. By deriving the necessary correction factors for determining the absolute dose (ie, in Gy) of FLASH photon radiation therapy, the uncertainty in water absorbed dose measurement is determined to be 1.0% (k = 1). CONCLUSIONS: This study develops a probe-type graphite calorimeter for the absolute measurement of absorbed dose to water in 10 MV FLASH x-ray beams. The system is designed to address the current lack of a traceable dosimetric standard for x-ray FLASH radiation therapy, thereby supporting its clinical translation and application.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Division of Ionizing Radiation Metrology, National Institute of Metrology (NIM), Beijing, China.
- Division of Ionizing Radiation Metrology, National Institute of Metrology (NIM), Beijing, China. Electronic address: wangkun@nim.ac.cn.
- Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang, China. Electronic address: winfield1920@126.com.
- Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang, China. Electronic address: wudai04@163.com.
- School of Radiation Medicine and Protection, Suzhou Medical College of Soochow University, Suzhou, China.
- Beijing Cancer Hospital, Beijing, China.
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
Zitieren
APA
Huang, J., Zhang, G., Wang, K., Tian, B., Yang, Y., Wu, D., Jin, S., Wang, Z., Qi, Y., Zhang, H., Zhang, H., Wu, H., Yan, X., & Subiel, A. (2026). The Quasi-Adiabatic Graphite Calorimeter for Absolute Dosimetry in Ultrahigh Dose Rate FLASH X-Ray Radiation Therapy. International Journal of Radiation Oncology*Biology*Physics, 126(2), 568-578. https://doi.org/10.1016/j.ijrobp.2026.03.028
Vancouver
Huang J, Zhang G, Wang K, Tian B, Yang Y, Wu D, et al. The Quasi-Adiabatic Graphite Calorimeter for Absolute Dosimetry in Ultrahigh Dose Rate FLASH X-Ray Radiation Therapy. International Journal of Radiation Oncology*Biology*Physics. 2026;126(2):568-578. doi:10.1016/j.ijrobp.2026.03.028
BibTeX
@article{Huang2026,
author = {Huang, Ji and Zhang, Guolong and Wang, Kun and Tian, Baolin and Yang, Yiwei and Wu, Dai and Jin, Sunjun and Wang, Zhipeng and Qi, Yaping and Zhang, Haowen and Zhang, Hui and Wu, Hao and Yan, Xueqing and Subiel, Anna},
title = {The Quasi-Adiabatic Graphite Calorimeter for Absolute Dosimetry in Ultrahigh Dose Rate FLASH X-Ray Radiation Therapy},
journal = {International Journal of Radiation Oncology*Biology*Physics},
year = {2026},
volume = {126},
number = {2},
pages = {568--578},
doi = {10.1016/j.ijrobp.2026.03.028}
}
EUVIMED