Experimentally derived beam quality correction factors for PPC05 and razor nano ionization chambers in proton scanned beams based on graphite calorimetry
Journal of Applied Clinical Medical Physics · 2026
DOI: 10.1002/acm2.70860 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Clinical Medical Physics, 2026. Verfasst von Nicolás Gómez-Fernández und 7 weiteren Autor:innen. Beteiligte Einrichtung: Radiation Physics Laboratory, AII, University of Santiago de Compostela, Santiago de Compostela, Spain. Hauptthemen laut MEDLINE: Calorimetry, Graphite, Monte Carlo Method, Radiometry. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Instituto de Salud Carlos III.
Abstract (Originalsprache)
Background
Ionization chamber based reference dosimetry of proton beam requires the use of beam quality correction factors which are obtained experimentally or by Monte Carlo simulation and are available to users in codes of practice and other publications.
Purpose
The aim of this work is to determine experimental proton beam quality correction factors, , for two ionization chambers using a portable graphite calorimeter: the IBA reference‐class PPC05 chamber and the IBA non reference‐class Razor Nano chamber, using a portable graphite calorimeter.
Methods
Measurements were performed in scanned clinical proton beams at two clinical centers. Absorbed dose to graphite was determined using a recently developed portable graphite calorimeter. The conversion factors for the absorbed dose to water determination were obtained by Monte Carlo simulations. Finally, the experimental factors were obtained by comparing ionization chamber readings with the calorimeter, measured using the same conditions, in terms of absorbed dose to water.
Results
For the IBA PPC05 chamber, the experimental values agreed with recommended values tabulated in TRS‐398 (rev. 1) within the combined experimental uncertainty for the three residual ranges of 3.4, 13.3 and 27.7 g·cm −2 . For Razor Nano chamber, values of 1.009 and 1.011 for residual ranges of 13.3 and 27.7 g·cm −2 have been determined. No recommended values are provided in TRS_398 (rev. 1). The overall budget yielded a combined standard uncertainty in the experimental determination of less than ().
Conclusions
This study demonstrates the feasibility and high precision of using a portable graphite calorimeter for beam quality correction factor determination in the user beam quality. The short room occupation time required (around 3 hours) makes the system useful as well for beam output dosimetry audits without disturbing clinical practice.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Radiation Physics Laboratory, AII, University of Santiago de Compostela, Santiago de Compostela, Spain.
- Clinical Department, Dosimetry, Ion Beam Applications, Louvain-la-Neuve, Belgium.
- Institut de Recherche Expérimentale et Clinique-Molecular Imaging Radiotherapy and Oncology (MIRO), UCLouvain, Louvain-la-Neuve, Belgium.
- Departamento de Física de Partículas, Universidade de Santiago de Compostela, Santiago de Compostela, Spain.
- Centro Protonterapia, QuironSalud, Pozuelo de Alarcón, Spain.
- Fundación de Investigación Sanitaria de Santiago, Santiago de Compostela, Spain.
Förderung
- Instituto de Salud Carlos III
Zitieren
APA
Gómez-Fernández, N., Rossomme, S., González-García, E., Verpoest, L., Gómez, F., Mazal, A., Vera-Sánchez, J. A., & González Castaño, D. M. (2026). Experimentally derived beam quality correction factors for PPC05 and razor nano ionization chambers in proton scanned beams based on graphite calorimetry. Journal of Applied Clinical Medical Physics. https://doi.org/10.1002/acm2.70860
Vancouver
Gómez-Fernández N, Rossomme S, González-García E, Verpoest L, Gómez F, Mazal A, et al. Experimentally derived beam quality correction factors for PPC05 and razor nano ionization chambers in proton scanned beams based on graphite calorimetry. Journal of Applied Clinical Medical Physics. 2026. doi:10.1002/acm2.70860
BibTeX
@article{GmezFernndez2026,
author = {Gómez-Fernández, Nicolás and Rossomme, Séverine and González-García, Eloy and Verpoest, Lies and Gómez, Faustino and Mazal, Alejandro and Vera-Sánchez, Juan Antonio and González Castaño, Diego M},
title = {Experimentally derived beam quality correction factors for PPC05 and razor nano ionization chambers in proton scanned beams based on graphite calorimetry},
journal = {Journal of Applied Clinical Medical Physics},
year = {2026},
doi = {10.1002/acm2.70860}
}
EUVIMED