A leadless ventricular pacemaker providing atrioventricular synchronous pacing in the real-world setting: 12-Month results from the Micra AV post-approval registry
Heart Rhythm · 2024-10 · 21 (10) · 1939-1947
DOI: 10.1016/j.hrthm.2024.06.008 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Heart Rhythm, 2024-10. Verfasst von Christophe Garweg und 15 weiteren Autor:innen. Beteiligte Einrichtung: University Hospitals Leuven, Leuven, Belgium. Electronic address: christophe.garweg@uzleuven.be. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Registries, Cardiac Pacing, Artificial. Die Arbeit wurde bisher 36-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Medtronic Inc.
Abstract (Originalsprache)
BACKGROUND: Advances in leadless pacemaker technology have enabled accelerometer-based atrioventricular (AV) synchronous pacing by sensing atrial mechanical contraction. OBJECTIVE: The purpose of this study was to report the performance of the Micra AV leadless pacemaker from the worldwide Micra AV post-approval registry (PAR) through 12 months. METHODS: The Micra AV PAR is a prospective, single-arm, observational registry designed to assess the safety and effectiveness of Micra AV in a real-world setting. For the present interim analysis, major complications and system revisions through 12 months were summarized and compared to a historical cohort of 2667 patients implanted with a transvenous dual-chamber pacing system. RESULTS: The device was successfully implanted in 796 of 801 patients (99.4%) at 97 centers in 19 countries. Micra AV patients were older (74.1 years vs 71.1 years; P 90%. CONCLUSION: The Micra AV leadless pacemaker was implanted with a high rate of success in patients with multiple comorbidities, with a significantly lower rate of complications and system revisions through 12 months compared to a historical cohort of patients with transvenous dual-chamber pacemakers.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- University Hospitals Leuven, Leuven, Belgium. Electronic address: christophe.garweg@uzleuven.be.
- Northwell New Hyde Park, New Hyde Park, New York.
- European Georges Pompidou Hospital, Paris, France.
- Bern University Hospital, University of Bern, Bern, Switzerland.
- Saint Vinzenz Hospital, Cologne, Germany.
- Maria Cecilia Hospital, GVM Care & Research, Cotignola, Italy.
Förderung
- Medtronic Inc
Zitieren
APA
Garweg, C., Chinitz, J. S., Marijon, E., Haeberlin, A., Winter, S., Iacopino, S., Curnis, A., Breitenstein, A., Hussin, A., Mela, T., El-Chami, M. F., Roberts, P. R., Piccini, J. P., Stromberg, K., Fagan, D. H., & Clementy, N. (2024). A leadless ventricular pacemaker providing atrioventricular synchronous pacing in the real-world setting: 12-Month results from the Micra AV post-approval registry. Heart Rhythm, 21(10), 1939-1947. https://doi.org/10.1016/j.hrthm.2024.06.008
Vancouver
Garweg C, Chinitz JS, Marijon E, Haeberlin A, Winter S, Iacopino S, et al. A leadless ventricular pacemaker providing atrioventricular synchronous pacing in the real-world setting: 12-Month results from the Micra AV post-approval registry. Heart Rhythm. 2024;21(10):1939-1947. doi:10.1016/j.hrthm.2024.06.008
BibTeX
@article{Garweg2024,
author = {Garweg, Christophe and Chinitz, Jason S and Marijon, Eloi and Haeberlin, Andreas and Winter, Stefan and Iacopino, Saverio and Curnis, Antonio and Breitenstein, Alexander and Hussin, Azlan and Mela, Theofanie and El-Chami, Mikhael F and Roberts, Paul R and Piccini, Jonathan P and Stromberg, Kurt and Fagan, Dedra H and Clementy, Nicolas},
title = {A leadless ventricular pacemaker providing atrioventricular synchronous pacing in the real-world setting: 12-Month results from the Micra AV post-approval registry},
journal = {Heart Rhythm},
year = {2024},
volume = {21},
number = {10},
pages = {1939--1947},
doi = {10.1016/j.hrthm.2024.06.008}
}
EUVIMED