EUVIMEDEUVIMED entdecken
Beobachtungsstudie

Risk factors associated with clinically relevant pericardial effusion after primary cardiac implantable electronic device implantation

Yangzhi Zhou iD, Saranda Haxha, Andrim Halili, Berit T Philbert, Olav W Nielsen, Ahmad Sajadieh, Lars Koeber, Gunnar H Gislason, Christian Torp-Pedersen, Casper N Bang

Journal of Cardiovascular Electrophysiology · 2024

DOI: 10.1111/jce.16442 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Yangzhi Zhou und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Pericardial Effusion, Pacemaker, Artificial, Registries, Defibrillators, Implantable. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Bispebjerg and Frederiksberg Hospital, Department of Cardiology, Copenhagen, Denmark.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Pericardial effusion, a known complication to implantation of cardiac implantable electronic devices (CIED), may cause life‐threatening cardiac tamponade. Limited knowledge is available about risk factors for clinically relevant procedural pericardial effusion. The aim is to identify the patient‐ and procedure‐related risk factors associated with clinically relevant procedural pericardial effusion.

Method

A nationwide observational cohort study based on data on 55 121 patients from the Danish Pacemaker Register between 2000 and 2018. We defined a clinically relevant procedural pericardial effusion related to the implantation if it occurred within 90 days after the primary CIED‐procedure. Prespecified risk factors were analysed by multivariable logistic regression models to estimate the association with pericardial effusion.

Results

There were 115 (0.21%) patients diagnosed with clinically relevant procedural pericardial effusion, with a median age of 75 years and 38.3% were females. Of these, 80.9% lead to a subsequent pericardiocentesis procedure. In adjusted logistic regression analysis, an increased risk of clinically relevant pericardial effusion was associated with female sex (OR:1.49 [95%CI: 1.03–2.16]), heart failure (OR:1.54 [95%CI: 1.06–2.23]), previous cardiac surgery (OR:1.63 [95%CI: 1.05–2.55]), CRT‐device (OR:2.05 [95%CI: 1.23–3.41]), tertiary‐centres (OR:1.8 [95%CI: 1.18–2.73]), increased procedural volume per year (>1000) (OR:1.85 [95%CI: 1.03–3.30]), indication of device‐implantation (atrioventricular block) (OR:2.37 [95CI: 1.45–3.87]), and increasing number of leads implanted (two leads (OR:2.39 [95%CI: 1.43–4.00]), three leads (OR:4.77 [95%CI: 2.50–9.10])).

Conclusion

Clinically relevant procedural pericardial effusion is a rare complication after CIED‐implantation in Denmark. This study reveals important patient‐ and procedure‐related risk factors associated with clinically relevant procedural pericardial effusion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Pericardial EffusionPacemaker, ArtificialRegistriesDefibrillators, ImplantableHumansFemaleMaleRisk FactorsAgedAged, 80 and overDenmarkRisk AssessmentMiddle AgedTime FactorsTreatment OutcomeSex FactorsCardiac Pacing, ArtificialCardiac Resynchronization Therapy Devices

Stichwörter der Autor:innen

cardiac implantable electronic devicecardiac tamponadeclinically relevant pericardial effusionpericardiocentesispostprocedural complication

Autor:innen und Institutionen

  • Department of Cardiology, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark.
  • Department of Cardiology, North Zealand Hospital, Hilleroed, Denmark.
  • Department of Cardiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen, Denmark.
  • Department of Cardiology, Herlev-Gentofte Hospital, Copenhagen, Denmark.

ORCID-Profile: Yangzhi Zhou

Förderung

  • Bispebjerg and Frederiksberg Hospital, Department of Cardiology, Copenhagen, Denmark

Zitieren

APA

Zhou, Y., Haxha, S., Halili, A., Philbert, B. T., Nielsen, O. W., Sajadieh, A., Koeber, L., Gislason, G. H., Torp-Pedersen, C., & Bang, C. N. (2024). Risk factors associated with clinically relevant pericardial effusion after primary cardiac implantable electronic device implantation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16442

Vancouver

Zhou Y, Haxha S, Halili A, Philbert BT, Nielsen OW, Sajadieh A, et al. Risk factors associated with clinically relevant pericardial effusion after primary cardiac implantable electronic device implantation. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16442

BibTeX
@article{Zhou2024,
  author = {Zhou, Yangzhi and Haxha, Saranda and Halili, Andrim and Philbert, Berit T and Nielsen, Olav W and Sajadieh, Ahmad and Koeber, Lars and Gislason, Gunnar H and Torp-Pedersen, Christian and Bang, Casper N},
  title = {Risk factors associated with clinically relevant pericardial effusion after primary cardiac implantable electronic device implantation},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2024},
  doi = {10.1111/jce.16442}
}
Kostenlos starten →