Risk factors associated with clinically relevant pericardial effusion after primary cardiac implantable electronic device implantation
Journal of Cardiovascular Electrophysiology · 2024
DOI: 10.1111/jce.16442 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Journal of Cardiovascular Electrophysiology, 2024. Verfasst von Yangzhi Zhou und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiology, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Pericardial Effusion, Pacemaker, Artificial, Registries, Defibrillators, Implantable. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: Bispebjerg and Frederiksberg Hospital, Department of Cardiology, Copenhagen, Denmark.
Abstract (Originalsprache)
Introduction
Pericardial effusion, a known complication to implantation of cardiac implantable electronic devices (CIED), may cause life‐threatening cardiac tamponade. Limited knowledge is available about risk factors for clinically relevant procedural pericardial effusion. The aim is to identify the patient‐ and procedure‐related risk factors associated with clinically relevant procedural pericardial effusion.
Method
A nationwide observational cohort study based on data on 55 121 patients from the Danish Pacemaker Register between 2000 and 2018. We defined a clinically relevant procedural pericardial effusion related to the implantation if it occurred within 90 days after the primary CIED‐procedure. Prespecified risk factors were analysed by multivariable logistic regression models to estimate the association with pericardial effusion.
Results
There were 115 (0.21%) patients diagnosed with clinically relevant procedural pericardial effusion, with a median age of 75 years and 38.3% were females. Of these, 80.9% lead to a subsequent pericardiocentesis procedure. In adjusted logistic regression analysis, an increased risk of clinically relevant pericardial effusion was associated with female sex (OR:1.49 [95%CI: 1.03–2.16]), heart failure (OR:1.54 [95%CI: 1.06–2.23]), previous cardiac surgery (OR:1.63 [95%CI: 1.05–2.55]), CRT‐device (OR:2.05 [95%CI: 1.23–3.41]), tertiary‐centres (OR:1.8 [95%CI: 1.18–2.73]), increased procedural volume per year (>1000) (OR:1.85 [95%CI: 1.03–3.30]), indication of device‐implantation (atrioventricular block) (OR:2.37 [95CI: 1.45–3.87]), and increasing number of leads implanted (two leads (OR:2.39 [95%CI: 1.43–4.00]), three leads (OR:4.77 [95%CI: 2.50–9.10])).
Conclusion
Clinically relevant procedural pericardial effusion is a rare complication after CIED‐implantation in Denmark. This study reveals important patient‐ and procedure‐related risk factors associated with clinically relevant procedural pericardial effusion.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiology, Bispebjerg and Frederiksberg Hospital, Copenhagen, Denmark.
- Department of Cardiology, North Zealand Hospital, Hilleroed, Denmark.
- Department of Cardiology, Rigshospitalet - Copenhagen University Hospital, Copenhagen, Denmark.
- Department of Cardiology, Herlev-Gentofte Hospital, Copenhagen, Denmark.
ORCID-Profile: Yangzhi Zhou
Förderung
- Bispebjerg and Frederiksberg Hospital, Department of Cardiology, Copenhagen, Denmark
Zitieren
APA
Zhou, Y., Haxha, S., Halili, A., Philbert, B. T., Nielsen, O. W., Sajadieh, A., Koeber, L., Gislason, G. H., Torp-Pedersen, C., & Bang, C. N. (2024). Risk factors associated with clinically relevant pericardial effusion after primary cardiac implantable electronic device implantation. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.16442
Vancouver
Zhou Y, Haxha S, Halili A, Philbert BT, Nielsen OW, Sajadieh A, et al. Risk factors associated with clinically relevant pericardial effusion after primary cardiac implantable electronic device implantation. Journal of Cardiovascular Electrophysiology. 2024. doi:10.1111/jce.16442