Potential microemboli formation risk and its management during the heated saline–enhanced radiofrequency needle-tip catheter ablation
Heart Rhythm · 2024
DOI: 10.1016/j.hrthm.2024.05.050 ↗Kurz gefasst
Fachartikel in der Zeitschrift Heart Rhythm, 2024. Verfasst von Atsushi Suzuki und 9 weiteren Autor:innen. Beteiligte Einrichtung: Translational Interventional Electrophysiology Laboratory, Mayo Clinic/St. Marys Campus, Rochester, Minnesota; Department of Cardiology, Yodogawa Chr…. Hauptthemen laut MEDLINE: Catheter Ablation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 16 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: The potential risk of embolic events during ablation in the left ventricle (LV) with a heated saline-enhanced radiofrequency (SERF) needle-tip ablation catheter has not been characterized. OBJECTIVE: This study aimed to investigate the formation of microemboli or other untoward events during SERF ablation. METHODS: Ninety-three radiofrequency (RF) ablation procedures were performed in the LV of 14 pigs by using a SERF catheter (35 W, 70 seconds, and 60°C; normal or degassed saline [NS or DS] irrigation with a flow rate of 10 mL/min) vs a standard irrigated-tip radiofrequency (S-RF) catheter (30 or 50 W, 30 seconds, and 17 mL/min). Microbubble formation was graded on the basis of intracardiac echocardiography. Microbubbles, microembolic signals, and microparticles were monitored using our established model. RESULTS: There was no significant difference in microbubble volume among SERF-NS, SERF-DS, and S-RF 30 W with "grade 1" intracardiac echocardiography microbubbles (median and 25th-75th percentiles 0.201 [0.011-3.13], 0.455 [0.06-2.66], and 0.004 μL [0.00-0.16 μL], respectively). There was no significant difference in microembolic signals among SERF-NS, SERF-DS, and S-RF 30 W with grade 1 bubbles (n = 8.0 ± 5.8, n = 7.6 ± 4.2, and n = 6.1 ± 6.1, respectively). Both SERF-NS and SERF-DS created larger lesions than did both S-RF 30 W and S-RF 50 W deliveries (mean 1241.5 ± 658.6, 1497.7 ± 893.4, 75.0 ± 24.8, and 184.0 ± 93.8 mm3; P < .001). There was no significant difference in microparticle incidence among groups (P = .675). No evidence of embolic events was found in the brain and other organs at the histology assessment. CONCLUSION: In the setting of SERF ablation, significantly large LV lesions can be created without any increment in embolic microbubble or particle events. Grade 1 microbubble is related to the efficacy and safety.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Translational Interventional Electrophysiology Laboratory, Mayo Clinic/St. Marys Campus, Rochester, Minnesota; Department of Cardiology, Yodogawa Christian Hospital, Osaka, Japan.
- Translational Interventional Electrophysiology Laboratory, Mayo Clinic/St. Marys Campus, Rochester, Minnesota; Department of Cardiology, Corrigan Minehan Heart Center, Massachusetts General Hospital, Boston, Massachuset…
- Translational Interventional Electrophysiology Laboratory, Mayo Clinic/St. Marys Campus, Rochester, Minnesota.
- Translational Interventional Electrophysiology Laboratory, Mayo Clinic/St. Marys Campus, Rochester, Minnesota; Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, China.
- Thermedical, Waltham, Massachusetts.
- Translational Interventional Electrophysiology Laboratory, Mayo Clinic/St. Marys Campus, Rochester, Minnesota. Electronic address: douglaspacker589@gmail.com.
Zitieren
APA
Suzuki, A., Lehmann, H. I., Konishi, H., Wang, S., Hohmann, S., Rettman, M. E., Newman, L. K., Parker, K. D., Curley, M. G., & Packer, D. L. (2024). Potential microemboli formation risk and its management during the heated saline–enhanced radiofrequency needle-tip catheter ablation. Heart Rhythm. https://doi.org/10.1016/j.hrthm.2024.05.050
Vancouver
Suzuki A, Lehmann HI, Konishi H, Wang S, Hohmann S, Rettman ME, et al. Potential microemboli formation risk and its management during the heated saline–enhanced radiofrequency needle-tip catheter ablation. Heart Rhythm. 2024. doi:10.1016/j.hrthm.2024.05.050
BibTeX
@article{Suzuki2024,
author = {Suzuki, Atsushi and Lehmann, H Immo and Konishi, Hiroki and Wang, Songyun and Hohmann, Stephan and Rettman, Maryam E and Newman, Laura K and Parker, Kay D and Curley, Michael G and Packer, Douglas L},
title = {Potential microemboli formation risk and its management during the heated saline–enhanced radiofrequency needle-tip catheter ablation},
journal = {Heart Rhythm},
year = {2024},
doi = {10.1016/j.hrthm.2024.05.050}
}
EUVIMED