EUVIMEDEUVIMED entdecken
Crossref

Streamlining liver iron assessment: accuracy and limitations of 3D qDixon MRI for liver iron overload quantification

Fei Peng, Chaotian Luo, Xiaojing Ning, Linlin Liang, Chaojie Huang, Mingrui Yang, Cheng Tang, Huiting Zhang, Peng Peng

European Journal of Radiology · 2025

DOI: 10.1016/j.ejrad.2025.112237 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Journal of Radiology, 2025. Verfasst von Fei Peng und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning 530021 Guangxi, China. Hauptthemen laut MEDLINE: Iron Overload, Magnetic Resonance Imaging, Liver, Imaging, Three-Dimensional. Die Arbeit nennt 39 Literaturangaben. Gefördert von: Education Department of Guangxi Zhuang Autonomous Region, Natural Science Foundation of Guangxi Zhuang Autonomous Region, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE: To prospectively evaluate the accuracy and limitations of the 1.5 T 3D-Dixon sequence (qDixon) in quantifying liver iron concentration (LIC), using FerriScan technology-determined LIC and the 1.5 T multi-echo GRE sequence (ME-GRE) as reference standards. METHODS: A total of 161 chronic transfusion-dependent patients, 83 men and 43 women with a mean age of 21.04 years, were scanned using ME-GRE and qDixon sequences; among them, 67 were scanned using FerriScan technology. R2* values (ME-GRE-R2* and qDixon-R2*) and LIC were obtained for both sequences. Comparative analysis was conducted using concordance correlation coefficients (CCC), Bland-Altman plots, and linear regression. A piecewise regression model was constructed to determine the upper limit for quantifying LIC using the qDixon. RESULTS: The qDixon-LIC and ME-GRE-LIC showed mean differences of 0.22, 0.01, -0.27, and 6.8 mg/g dry weight (dw) in normal, mild, moderate, and severe liver iron overload with corresponding CCC values of 0.986, 0.982, 0.956, and 0.216, respectively. The piecewise regression model established a 28.47 mg/g dw threshold for accurate liver iron quantification using qDixon, beyond which qDixon-R2* reached 892.86 s-1. Below this threshold, qDixon demonstrated a strong linear correlation with FerriScan in estimating LIC (r = 0.82, p < 0.001), with a negligible mean difference of 1.68 mg/g dw and a CCC of 0.984. CONCLUSION: The 1.5 T qDixon sequence can be used to quantitatively assess LIC within a specific range (LIC < 28.47 mg/g dw), simplifying clinical workflow procedures.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Iron OverloadMagnetic Resonance ImagingLiverImaging, Three-DimensionalIronImage Interpretation, Computer-AssistedHumansFemaleMaleReproducibility of ResultsAdultSensitivity and SpecificityYoung AdultProspective StudiesMiddle AgedAdolescent

Stichwörter der Autor:innen

Dixon TechniqueIron overloadLiverMagnetic resonance imagingR2* relaxometry

Substanzen

Iron

Autor:innen und Institutionen

  • Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning 530021 Guangxi, China.
  • Department of Radiology, The First Affiliated Hospital of Guangxi Medical University, Nanning 530021 Guangxi, China; NHC Key Laboratory of Thalassemia Medicine, Guangxi Medical University, Nanning, Guangxi 530021, China…
  • MR Research Collaboration, Siemens Healthineers Ltd., Wuhan 430000, China.

Förderung

  • Education Department of Guangxi Zhuang Autonomous Region
  • Natural Science Foundation of Guangxi Zhuang Autonomous Region
  • National Natural Science Foundation of China
  • Guangxi Medical University

Zitieren

APA

Peng, F., Luo, C., Ning, X., Liang, L., Huang, C., Yang, M., Tang, C., Zhang, H., & Peng, P. (2025). Streamlining liver iron assessment: accuracy and limitations of 3D qDixon MRI for liver iron overload quantification. European Journal of Radiology. https://doi.org/10.1016/j.ejrad.2025.112237

Vancouver

Peng F, Luo C, Ning X, Liang L, Huang C, Yang M, et al. Streamlining liver iron assessment: accuracy and limitations of 3D qDixon MRI for liver iron overload quantification. European Journal of Radiology. 2025. doi:10.1016/j.ejrad.2025.112237

BibTeX
@article{Peng2025,
  author = {Peng, Fei and Luo, Chaotian and Ning, Xiaojing and Liang, Linlin and Huang, Chaojie and Yang, Mingrui and Tang, Cheng and Zhang, Huiting and Peng, Peng},
  title = {Streamlining liver iron assessment: accuracy and limitations of 3D qDixon MRI for liver iron overload quantification},
  journal = {European Journal of Radiology},
  year = {2025},
  doi = {10.1016/j.ejrad.2025.112237}
}
Kostenlos starten →