Vergleichsstudie in der Zeitschrift Magnetic Resonance Imaging, 2024. Verfasst von Marshall S Sussman und 4 weiteren Autor:innen. Beteiligte Einrichtung: Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital, and Women's College Hospital, University of Toronto, Toronto, O…. Hauptthemen laut MEDLINE: Iron Overload, Magnetic Resonance Imaging, Liver, Iron. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study assessed the clinical classification performance of an R2*-based MRI technique for LIC quantification relative to FerriScan, with intra-patient FerriScan LIC uncertainty taken into account. The variabilities of R2* and FerriScan LIC were also assessed. MATERIALS AND METHODS: This was an ethics approved retrospective study, performed on patients undergoing chelation treatment for iron overload. 126 patients (69 women, 57 men), with an age of 42 +/- 16 years (range 19-86 years) were included. FerriScan and R2* MRI at 1.5 T were performed as part of a routine liver iron assessment protocol. For R2* MRI, a commercially available pulse sequence and reconstruction implementation was used, together with a previously derived calibration curve to convert R2* to LIC. Clinical classifications arising from R2*-derived LIC estimates were compared to those based on FerriScan. The accuracy and precision of the R2* technique was calculated. The variabilities of FerriScan- and R2*-derived estimates of LIC were compared with a Wilcoxon Signed Rank test. Significance was set at the 95% confidence level. RESULTS: The precision of R2* ranged from 0.59 to 0.92, with an overall accuracy of 72%. When intra-patient FerriScan LIC uncertainty was considered, precision and accuracy increased to >94% and 97% respectively. The R2*-LIC variability (=17%) was significantly lower than the FerriScan-LIC variability (34%) at the 95% confidence level (p < 10-3). CONCLUSION: MRI R2*-based LIC estimates provided a similar clinical classification as FerriScan. The intra-patient uncertainty of R2*-based LIC estimates was significantly lower than FerriScan.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Iron OverloadMagnetic Resonance ImagingLiverIronHumansAdultMaleFemaleMiddle AgedAgedAged, 80 and overReproducibility of ResultsYoung AdultRetrospective StudiesSensitivity and SpecificityMagnetite NanoparticlesContrast Media

Stichwörter der Autor:innen

Iron overloadLiverMagnetic resonance imagingMagnetic resonance imaging methodsMagnetic resonance imaging statistics and numerical data

Substanzen

IronMagnetite NanoparticlesContrast Media

Autor:innen und Institutionen

  • Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital, and Women's College Hospital, University of Toronto, Toronto, ON, Canada.
  • MR Applications Predevelopment, Siemens Healthcare, Erlangen, Germany.
  • Division of Medical Oncology & Hematology, University Health Network, University of Toronto, Toronto, ON, Canada.
  • Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital, and Women's College Hospital, University of Toronto, Toronto, ON, Canada. Electronic address: kartik.jhaveri@uhn.ca.

Zitieren

APA

Sussman, M. S., Kannengiesser, S. A. R., Prasla, S., Ward, R., & Jhaveri, K. S. (2024). Comparison of R2* and FerriScan liver iron concentration (LIC) quantification in the clinical classification of Iron overload states. Magnetic Resonance Imaging. https://doi.org/10.1016/j.mri.2024.110216

Vancouver

Sussman MS, Kannengiesser SAR, Prasla S, Ward R, Jhaveri KS. Comparison of R2* and FerriScan liver iron concentration (LIC) quantification in the clinical classification of Iron overload states. Magnetic Resonance Imaging. 2024. doi:10.1016/j.mri.2024.110216

BibTeX
@article{Sussman2024,
  author = {Sussman, Marshall S and Kannengiesser, Stephan A R and Prasla, Shopnil and Ward, Richard and Jhaveri, Kartik S},
  title = {Comparison of R2* and FerriScan liver iron concentration (LIC) quantification in the clinical classification of Iron overload states},
  journal = {Magnetic Resonance Imaging},
  year = {2024},
  doi = {10.1016/j.mri.2024.110216}
}
Kostenlos starten →