Practical Application of Multivendor MRI ‐Based R2* Mapping for Liver Iron Quantification at 1.5 T and 3.0 T
Journal of Magnetic Resonance Imaging · 2025
DOI: 10.1002/jmri.29401 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Magnetic Resonance Imaging, 2025. Verfasst von Gregory Simchick und 15 weiteren Autor:innen. Beteiligte Einrichtung: Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA. Hauptthemen laut MEDLINE: Liver, Magnetic Resonance Imaging, Iron, Iron Overload. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIH HHS, NIDDK NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
Background
Recent multicenter, multivendor MRI‐based R2* vs. liver iron concentration (LIC) calibrations (i.e., MCMV calibrations) may facilitate broad clinical dissemination of R2*‐based LIC quantification. However, these calibrations are based on a centralized offline R2* reconstruction, and their applicability with vendor‐provided R2* maps is unclear.
Purpose
To determine R2* ranges of agreement between the centralized and three MRI vendors' R2* reconstructions. Study Type Prospective. Subjects Two hundred and seven subjects (mean age 37.6 ± 19.6 years; 117 male) with known or suspected iron overload from four academic medical centers. Field Strength/Sequence Standardized multiecho spoiled gradient echo sequence at 1.5 T and 3.0 T for R2* mapping and a multiple spin‐echo sequence at 1.5 T for LIC quantification. MRI vendors: GE Healthcare, Philips Healthcare, and Siemens Healthineers. Assessment R2* maps were generated using both the centralized and vendor reconstructions, and ranges of agreement were determined. R2*‐LIC linear calibrations were determined for each site, field strength, and reconstruction and compared with the MCMV calibrations. Statistical Tests Bland–Altman analysis to determine ranges of agreement. Linear regression, analysis of covariance F tests, and Tukey's multiple comparison testing to assess reproducibility of calibrations across sites and vendors. A P value
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.
- Radiology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
- Radiology, Johns Hopkins University, Baltimore, Maryland, USA.
- Department of Diagnostic and Interventional Radiology, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
- Medicine, University of Wisconsin-Madison, Madison, Wisconsin, USA.
ORCID-Profile: Gregory Simchick, Ruiyang Zhao, Qing Yuan, Mounes Aliyari Ghasabeh, Stefan Ruschke, Dimitrios C Karampinos, David T Harris, Ryan J Mattison, Michael R Jeng, Ivan Pedrosa, Ihab R Kamel, Shreyas Vasanawala, Takeshi Yokoo, Scott B Reeder, Diego Hernando
Förderung
- NIH HHS
- NIDDK NIH HHS
- National Institutes of Health
Zitieren
APA
Simchick, G., Zhao, R., Yuan, Q., Ghasabeh, M. A., Ruschke, S., Karampinos, D. C., Harris, D. T., do Vale Souza, R., Mattison, R. J., Jeng, M. R., Pedrosa, I., Kamel, I. R., Vasanawala, S., Yokoo, T., Reeder, S. B., & Hernando, D. (2025). Practical Application of Multivendor MRI ‐Based R2* Mapping for Liver Iron Quantification at 1.5 T and 3.0 T. Journal of Magnetic Resonance Imaging. https://doi.org/10.1002/jmri.29401
Vancouver
Simchick G, Zhao R, Yuan Q, Ghasabeh MA, Ruschke S, Karampinos DC, et al. Practical Application of Multivendor MRI ‐Based R2* Mapping for Liver Iron Quantification at 1.5 T and 3.0 T. Journal of Magnetic Resonance Imaging. 2025. doi:10.1002/jmri.29401
BibTeX
@article{Simchick2025,
author = {Simchick, Gregory and Zhao, Ruiyang and Yuan, Qing and Ghasabeh, Mounes Aliyari and Ruschke, Stefan and Karampinos, Dimitrios C and Harris, David T and do Vale Souza, Raphael and Mattison, Ryan J and Jeng, Michael R and Pedrosa, Ivan and Kamel, Ihab R and Vasanawala, Shreyas and Yokoo, Takeshi and Reeder, Scott B and Hernando, Diego},
title = {Practical Application of Multivendor MRI ‐Based R2* Mapping for Liver Iron Quantification at 1.5 T and 3.0 T},
journal = {Journal of Magnetic Resonance Imaging},
year = {2025},
doi = {10.1002/jmri.29401}
}
EUVIMED