EUVIMEDEUVIMED entdecken
Crossref

Revisiting signal intensity ratios for extending the dynamic range for iron overload estimation

Eamon K Doyle, Obdulio Carreras iD, John C Wood

Magnetic Resonance in Medicine · 2026

DOI: 10.1002/mrm.70078 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medicine, 2026. Verfasst von Eamon K Doyle und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Children's Hospital Los Angeles, Los Angeles, California, USA. Hauptthemen laut MEDLINE: Iron Overload, Liver, Magnetic Resonance Imaging, Iron. Die Arbeit nennt 13 Literaturangaben. Gefördert von: NIDDK NIH HHS, NCRR NIH HHS, NINDS NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The principles of signal‐intensity‐ratio (SIR) estimation were revisited to derive a set of generalizable equations to quantify liver iron concentration (LIC), extending the effective dynamic range of LIC‐R 2 * estimation or detect when LIC‐ R 2 * estimation degenerates. Theory and Methods Equations for LIC were derived for two techniques: (1) relaxometry of multi‐echo gradient echo and (2) SIR of liver and muscle tissue in a single echo. MRI was completed at 1.5T and 3T in human subjects with a range of liver iron burdens. LIC was estimated by both techniques and compared to assess concordance across the clinical range and high LIC performance.

Results

Regression of Log( SIR ) by LIC was linear for both 1. 5T and 3T data with similar slopes. Comparison between SIR ‐ LIC and R 2 *‐ LIC estimates demonstrated linear concordance until the echo time–based saturation of R 2 * estimates were reached, at which point SIR ‐ LIC estimates continued to rise without a concomitant increase in R 2 *‐ LIC . Lack of spatial intensity correction caused systematic bias and increased variance in LIC estimates compared to intensity‐corrected images.

Conclusions

LIC‐SIR measurements can potentially be used to estimate liver iron concentration in examinations where R 2 * acquisitions were not performed or where the dynamic range of a multi‐echo protocol is exceeded. Using spatial intensity correction where possible improves SIR‐LIC estimates.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Iron OverloadLiverMagnetic Resonance ImagingIronImage Interpretation, Computer-AssistedHumansAlgorithmsMaleFemaleAdultReproducibility of ResultsImage Processing, Computer-Assisted

Substanzen

Iron

Autor:innen und Institutionen

  • Department of Radiology, Children's Hospital Los Angeles, Los Angeles, California, USA.
  • Department of Pediatrics, Keck School of Medicine, University of Southern California, Los Angeles, California, USA.
  • Children's Hospital Los Angeles, Los Angeles, California, USA.
  • Department of Pediatrics, Division of Pediatric Cardiology, Children's Hospital Los Angeles, Los Angeles, California, USA.

ORCID-Profile: Obdulio Carreras

Förderung

  • NIDDK NIH HHS
  • NCRR NIH HHS
  • NINDS NIH HHS
  • National Institute of Diabetes and Digestive and Kidney Diseases
  • National Center for Research Resources
  • National Institute of Neurological Disorders and Stroke

Zitieren

APA

Doyle, E. K., Carreras, O., & Wood, J. C. (2026). Revisiting signal intensity ratios for extending the dynamic range for iron overload estimation. Magnetic Resonance in Medicine. https://doi.org/10.1002/mrm.70078

Vancouver

Doyle EK, Carreras O, Wood JC. Revisiting signal intensity ratios for extending the dynamic range for iron overload estimation. Magnetic Resonance in Medicine. 2026. doi:10.1002/mrm.70078

BibTeX
@article{Doyle2026,
  author = {Doyle, Eamon K and Carreras, Obdulio and Wood, John C},
  title = {Revisiting signal intensity ratios for extending the dynamic range for iron overload estimation},
  journal = {Magnetic Resonance in Medicine},
  year = {2026},
  doi = {10.1002/mrm.70078}
}
Kostenlos starten →