EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study

Joël Greffier, Sebastian Faby, Maxime Pastor, Julien Frandon, Julien Erath, Jean Paul Beregi, Djamel Dabli

Diagnostic and Interventional Imaging · 2024-09 · 105 (9) · 311-318

DOI: 10.1016/j.diii.2024.02.009 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Diagnostic and Interventional Imaging, 2024-09. Verfasst von Joël Greffier und 6 weiteren Autor:innen. Beteiligte Einrichtung: IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30029 Nîmes, France. Electronic address: joel.gr…. Hauptthemen laut MEDLINE: Phantoms, Imaging, Tomography, X-Ray Computed, Photons. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: The purpose of this study was to assess image quality and dose level using a photon-counting CT (PCCT) scanner by comparison with a dual-source CT (DSCT) scanner on virtual monoenergetic images (VMIs) at low energy levels. MATERIALS AND METHODS: A phantom was scanned using a DSCT and a PCCT with a volume CT dose index of 11 mGy, and additionally at 6 mGy and 1.8 mGy for PCCT. Noise power spectrum and task-based transfer function were evaluated from 40 to 70 keV on VMIs to assess noise magnitude and noise texture (fav) and spatial resolution on two iodine inserts (f50), respectively. A detectability index (d') was computed to assess the detection of two contrast-enhanced lesions according to the energy level used. RESULTS: For all energy levels, noise magnitude values were lower with PCCT than with DSCT at 11 and 6 mGy, but greater at 1.8 mGy. fav values were higher with PCCT than with DSCT at 11 mGy (8.6 ± 1.5 [standard deviation [SD]%), similar at 6 mGy (1.6 ± 1.5 [SD]%) and lower at 1.8 mGy (-17.8 ± 2.2 [SD]%). For both inserts, f50 values were higher with PCCT than DSCT at 11- and 6 mGy for all keV levels, except at 6 mGy and 40 keV. d' values were higher with PCCT than with DSCT at 11- and 6 mGy for all keV and both simulated lesions. Similar d' values to those of the DSCT at 11 mGy, were obtained at 2.25 mGy for iodine insert at 2 mg/mL and at 0.96 mGy for iodine insert at 4 mg/mL at 40 keV. CONCLUSION: Compared to DSCT, PCCT reduces noise magnitude and improves noise texture, spatial resolution and detectability on VMIs for all low-keV levels.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingTomography, X-Ray ComputedPhotonsRadiation DosageHumansSignal-To-Noise Ratio

Stichwörter der Autor:innen

Dual-energyIterative reconstructionMultidetector computed tomographyPhoton counting CTTask-based image quality assessment

Autor:innen und Institutionen

  • IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30029 Nîmes, France. Electronic address: joel.greffier@chu-nimes.fr.
  • Department of Computed Tomography, Siemens Healthineers AG, 91301 Forchheim, Germany.
  • IMAGINE UR UM 103, Montpellier University, Department of Medical Imaging, Nîmes University Hospital, 30029 Nîmes, France.

Zitieren

APA

Greffier, J., Faby, S., Pastor, M., Frandon, J., Erath, J., Beregi, J. P., & Dabli, D. (2024). Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study. Diagnostic and Interventional Imaging, 105(9), 311-318. https://doi.org/10.1016/j.diii.2024.02.009

Vancouver

Greffier J, Faby S, Pastor M, Frandon J, Erath J, Beregi JP, et al. Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study. Diagnostic and Interventional Imaging. 2024;105(9):311-318. doi:10.1016/j.diii.2024.02.009

BibTeX
@article{Greffier2024,
  author = {Greffier, Joël and Faby, Sebastian and Pastor, Maxime and Frandon, Julien and Erath, Julien and Beregi, Jean Paul and Dabli, Djamel},
  title = {Comparison of low-energy virtual monoenergetic images between photon-counting CT and energy-integrating detectors CT: A phantom study},
  journal = {Diagnostic and Interventional Imaging},
  year = {2024},
  volume = {105},
  number = {9},
  pages = {311--318},
  doi = {10.1016/j.diii.2024.02.009}
}
Kostenlos starten →