EUVIMEDEUVIMED entdecken
Crossref

Impact of ultra-low-dose imaging on image quality and volumetric accuracy of different subtypes of pulmonary nodules using photon-counting detector CT: a phantom study

Yajie Wang iD, Yuhan Zhou, Limin Lei, Xiaoxu Guo, Lina Tao, Yupu Ma, Yanru Ding, Jiaxi Nie, Songwei Yue iD

British Journal of Radiology · 01.09.2026 · 99 (1185) · 1795-1805

DOI: 10.1093/bjr/tqag127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Radiology, online erschienen am 26.05.2026. Verfasst von Yajie Wang und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, People's Republic of China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Solitary Pulmonary Nodule, Lung Neoplasms, Multiple Pulmonary Nodules. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 30 Literaturangaben. Gefördert von: Key Scientific Research Project of Colleges and Universities in Henan Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To evaluate the impact of ultra-high-resolution photon-counting detector CT (UHR PCD-CT) combined with ultra-low dose scanning protocol on the detection rate, image quality, diameter, and volumetric measurement accuracy of pulmonary nodules of varying sizes and types.

Methods

A thoracic phantom with 15 pulmonary nodule models was scanned on UHR PCD-CT at 5 dose levels. Quantitative analysis was performed on the detection rate, long-axis/short-axis diameters, noise value (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the nodules at each dose level. Pulmonary nodule AI diagnostic software was used to measure nodule volume and calculate the absolute percentage error in volume (APEvolume). Similarly, the absolute percentage error in diameter measurement (APEdiameter) was calculated. Subjective image quality was assessed using a 5-point scale, with images from the 1.00 mGy dose group as the reference.

Results

Dose reduction significantly lowered the detection rates of pulmonary nodules while increasing both APEdiameter and APEvolume. Solid nodules (SNs) exhibited better detectability compared to ground-glass nodules (GGNs), with nodules ≥6 mm showing superior performance over smaller lesions. Subjectively, performance at 0.50 mGy was clear but slightly worse than that at standard-dose (1.00 mGy) (all P < .05).

Conclusions

Even under ultra-low dose conditions (0.03-0.50 mGy), UHR PCD-CT combined with AI-assisted diagnostic software can still maintain the detection of pulmonary nodules and provide diagnostic-quality images. Advances in knowledge UHR PCD-CT is capable of yielding diagnostic image quality even at significantly reduced radiation doses, allowing for the confident assessment of specific nodule types and larger nodules.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedSolitary Pulmonary NoduleLung NeoplasmsMultiple Pulmonary NodulesPhantoms, ImagingRadiation DosageHumansSignal-To-Noise RatioRadiographic Image Interpretation, Computer-AssistedPhotons

Stichwörter der Autor:innen

anthropomorphic chest phantomdose reductionnodule volumetryphoton-counting detectorultra-low dose

Autor:innen und Institutionen

  • Department of Radiology, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, Henan Province 450052, People's Republic of China.
  • Zhengzhou University, Zhengzhou, Henan Province 450000, People's Republic of China.

ORCID-Profile: Yajie Wang, Songwei Yue

Förderung

  • Key Scientific Research Project of Colleges and Universities in Henan Province

Zitieren

APA

Wang, Y., Zhou, Y., Lei, L., Guo, X., Tao, L., Ma, Y., Ding, Y., Nie, J., & Yue, S. (2026). Impact of ultra-low-dose imaging on image quality and volumetric accuracy of different subtypes of pulmonary nodules using photon-counting detector CT: a phantom study. British Journal of Radiology, 99(1185), 1795-1805. https://doi.org/10.1093/bjr/tqag127

Vancouver

Wang Y, Zhou Y, Lei L, Guo X, Tao L, Ma Y, et al. Impact of ultra-low-dose imaging on image quality and volumetric accuracy of different subtypes of pulmonary nodules using photon-counting detector CT: a phantom study. British Journal of Radiology. 2026;99(1185):1795-1805. doi:10.1093/bjr/tqag127

BibTeX
@article{Wang2026,
  author = {Wang, Yajie and Zhou, Yuhan and Lei, Limin and Guo, Xiaoxu and Tao, Lina and Ma, Yupu and Ding, Yanru and Nie, Jiaxi and Yue, Songwei},
  title = {Impact of ultra-low-dose imaging on image quality and volumetric accuracy of different subtypes of pulmonary nodules using photon-counting detector CT: a phantom study},
  journal = {British Journal of Radiology},
  year = {2026},
  volume = {99},
  number = {1185},
  pages = {1795--1805},
  doi = {10.1093/bjr/tqag127}
}