EUVIMEDEUVIMED entdecken
Crossref

The Use of the Ascyrus Medical Dissection Stent in Acute Type A Aortic Dissection Repair Reduces Distal Anastomotic New Entry Tear

Abigail White, Lina Elfaki, Devin O'Brien, Vinod Manikala, Sabin Bozso, Maral Ouzounian, Michael C Moon

Canadian Journal of Cardiology · 2024-03 · 40 (3) · 470-475

DOI: 10.1016/j.cjca.2023.09.034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Canadian Journal of Cardiology, 2024-03. Verfasst von Abigail White und 6 weiteren Autor:innen. Beteiligte Einrichtung: University of Alberta, Edmonton, Alberta, Canada. Hauptthemen laut MEDLINE: Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis Implantation, Aortic Dissection. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: University of Alberta, University of Toronto.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: A distal anastomotic new entry tear (DANE) can occur at the time of surgical repair for acute type A aortic dissection (ATAAD). This study aimed to compare the occurrence of DANE following a standard hemiarch repair with that following a hemiarch repair with an uncovered arch dissection stent. METHODS: All patients who received a hemiarch repair or a hemiarch repair with an Ascyrus Medical Dissection Stent (AMDS) for ATAAD from 2017 to 2021 were included. Baseline and intra- and postoperative characteristics were collected. All available pre- and postoperative computed tomographic scans were analysed. The primary outcome measures were the incidence of DANE, positive aortic remodelling, mortality, and aortic reintervention rates at last follow-up. RESULTS: A total of 114 patients underwent repair of Debakey I ATAAD during the study period with either an isolated hemiarch (n = 77) or a hemiarch with AMDS (n = 37). There was no significant difference in mortality (P = 0.768) or other in-hospital adverse events. During the follow-up period, DANE occurred in 43.3% (n = 26) of the isolated hemiarch group and in 11.8% (n = 4) of the hemiarch with AMDS group (P = 0.002). The incidence of false lumen thrombosis and obliteration favoured the AMDS group in the aortic arch (P = 0.029), the proximal descending thoracic aorta (P = 0.031), and level of pulmonary artery bifurcation (P = 0.044). CONCLUSIONS: The incidence of DANE is significantly reduced with the addition of an AMDS at the time of hemiarch repair for ATAAD repair. Further follow-up is necessary to identify late aortic complications that may have been prevented by reducing the incidence of postoperative DANE.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Aortic Aneurysm, ThoracicBlood Vessel Prosthesis ImplantationAortic DissectionHumansTreatment OutcomeAcute DiseaseRetrospective StudiesStentsAorta, ThoracicPostoperative Complications

Autor:innen und Institutionen

  • University of Alberta, Edmonton, Alberta, Canada.
  • University of Toronto, Toronto, Ontario, Canada.

Förderung

  • University of Alberta
  • University of Toronto

Zitieren

APA

White, A., Elfaki, L., O'Brien, D., Manikala, V., Bozso, S., Ouzounian, M., & Moon, M. C. (2024). The Use of the Ascyrus Medical Dissection Stent in Acute Type A Aortic Dissection Repair Reduces Distal Anastomotic New Entry Tear. Canadian Journal of Cardiology, 40(3), 470-475. https://doi.org/10.1016/j.cjca.2023.09.034

Vancouver

White A, Elfaki L, O'Brien D, Manikala V, Bozso S, Ouzounian M, et al. The Use of the Ascyrus Medical Dissection Stent in Acute Type A Aortic Dissection Repair Reduces Distal Anastomotic New Entry Tear. Canadian Journal of Cardiology. 2024;40(3):470-475. doi:10.1016/j.cjca.2023.09.034

BibTeX
@article{White2024,
  author = {White, Abigail and Elfaki, Lina and O'Brien, Devin and Manikala, Vinod and Bozso, Sabin and Ouzounian, Maral and Moon, Michael C},
  title = {The Use of the Ascyrus Medical Dissection Stent in Acute Type A Aortic Dissection Repair Reduces Distal Anastomotic New Entry Tear},
  journal = {Canadian Journal of Cardiology},
  year = {2024},
  volume = {40},
  number = {3},
  pages = {470--475},
  doi = {10.1016/j.cjca.2023.09.034}
}
Kostenlos starten →