Multi-center experience with an off-the-shelf single retrograde thoracic branch endoprosthesis for acute aortic pathology
Journal of Vascular Surgery · 2025-04 · 81 (4) · 839-846
DOI: 10.1016/j.jvs.2024.12.007 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Vascular Surgery, 2025-04. Verfasst von Kathryn L DiLosa und 14 weiteren Autor:innen. Beteiligte Einrichtung: Division of Vascular Surgery, UC Davis Medical Center, Sacramento, CA. Electronic address: kldilosa@ucdavis.edu. Hauptthemen laut MEDLINE: Endovascular Procedures, Blood Vessel Prosthesis, Blood Vessel Prosthesis Implantation, Aorta, Thoracic. Die Arbeit wurde bisher 35-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
OBJECTIVE: The thoracic branch endoprosthesis (TBE) (W.L. Gore) offers an off-the-shelf single option for thoracic endovascular aortic repair (TEVAR) of aortic arch pathology with sealing in zones 0 to 2. This study reports the early outcomes of TBE-TEVAR for acute indications. METHODS: Clinical data, imaging, and outcomes of patients treated with TBE-TEVAR at seven institutions were retrospectively reviewed (March 2017 to March 2024). Patients treated for complicated aortic dissection, symptomatic aneurysm/pseudoaneurysm, or blunt traumatic aortic injury by urgent/emergent repair were included. End points were 30-day mortality, major adverse events (mortality, myocardial infarction, prolonged intubation, stroke, paraplegia, dialysis, or bowel ischemia), and technical success. RESULTS: Of 356 patients treated by TBE-TEVAR, 107 (69.0% male; mean age, 60 ± 15 years) underwent repair for acute indications including 70 dissections (65%), 21 symptomatic aneurysms/pseudoaneurysms (20%), and 16 blunt traumatic aortic injuries (15%). Eight patients (8%) had repair immediately after open ascending repair of a type A dissection. Proximal sealing was in zone 2 in 91 patients (89%) and zone 0 to 1 in 11 patients (11%) who required cervical debranching. Technical success was achieved in all (99%) except one patient with acute dissection and aneurysmal degeneration requiring staged repair. At 30 days, two patients (2%) died, and 19 patients (18%) developed major adverse events, including stroke in six patients (6%) and paraplegia in six patients (6%). Five patients (5%; all Zone 2) had retrograde dissections, all treated for acute or subacute dissection, with no mortality. Mean follow-up was 55 ± 171 days, and 96 patients (94%) had follow-up imaging. Type IA or III endoleak occurred in seven patients (7%), retrograde branch occlusion in one (1%), and eleven (10%) required reintervention. Cumulative aortic-related mortality was three (3%) from aortic rupture. CONCLUSIONS: Urgent/emergent TEVAR with the Gore TBE device in acute pathology offers low mortality, stroke, and paraplegia risk. Longer follow-up is needed to assess effectiveness of the repair.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Vascular Surgery, UC Davis Medical Center, Sacramento, CA. Electronic address: kldilosa@ucdavis.edu.
- Division of Vascular Surgery, The Keck School of Medicine of USC, Los Angeles, CA.
- Department of Cardiothoracic and Vascular Surgery, University of Texas Health Science Center at Houston, McGovern Medical School, Houston, TX.
- Division of Vascular Surgery, MedStar Washington Hospital Center, Washington, DC.
- Division of Vascular Surgery, Stanford University School of Medicine, Stanford, CA.
- Division of Vascular Surgery, University of Washington, Seattle, WA.
Zitieren
APA
DiLosa, K. L., Manesh, M., Kanamori, L. R., Chan, M., Magee, G. A., Fleischman, F., Lee, J. T., Zettervall, S. L., Sweet, M. P., Harding, J. P., Toursavadkohi, S., Fatima, J., Oderich, G. S., Han, S. M., & Maximus, S. (2025). Multi-center experience with an off-the-shelf single retrograde thoracic branch endoprosthesis for acute aortic pathology. Journal of Vascular Surgery, 81(4), 839-846. https://doi.org/10.1016/j.jvs.2024.12.007
Vancouver
DiLosa KL, Manesh M, Kanamori LR, Chan M, Magee GA, Fleischman F, et al. Multi-center experience with an off-the-shelf single retrograde thoracic branch endoprosthesis for acute aortic pathology. Journal of Vascular Surgery. 2025;81(4):839-846. doi:10.1016/j.jvs.2024.12.007
BibTeX
@article{DiLosa2025,
author = {DiLosa, Kathryn L and Manesh, Michelle and Kanamori, Lucas Ruiter and Chan, Mabel and Magee, Gregory A and Fleischman, Fernando and Lee, Jason T and Zettervall, Sara L and Sweet, Matthew P and Harding, Joel P and Toursavadkohi, Shahab and Fatima, Javairiah and Oderich, Gustavo S and Han, Sukgu M and Maximus, Steven},
title = {Multi-center experience with an off-the-shelf single retrograde thoracic branch endoprosthesis for acute aortic pathology},
journal = {Journal of Vascular Surgery},
year = {2025},
volume = {81},
number = {4},
pages = {839--846},
doi = {10.1016/j.jvs.2024.12.007}
}
EUVIMED