EUVIMEDObjevte EUVIMED
Crossref

The Use of the Ascyrus Medical Dissection Stent in Acute Type A Aortic Dissection Repair Reduces Distal Anastomotic New Entry Tear

Abigail White, Lina Elfaki, Devin O'Brien, Vinod Manikala, Sabin Bozso, Maral Ouzounian, Michael C Moon

Canadian Journal of Cardiology · 2024-03 · 40 (3) · 470-475

DOI: 10.1016/j.cjca.2023.09.034 ↗

At a glance

Journal article in Canadian Journal of Cardiology, 2024-03. Written by Abigail White and 6 co-authors. Institution: University of Alberta, Edmonton, Alberta, Canada. Major MEDLINE topics: Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis Implantation, Aortic Dissection. Cited 11 times so far (Crossref); 21 references. Funded by: University of Alberta, University of Toronto.

AbstraktSubjectsBibliografické údajeCiteRelated studies

Abstract (original language)

BACKGROUND: A distal anastomotic new entry tear (DANE) can occur at the time of surgical repair for acute type A aortic dissection (ATAAD). This study aimed to compare the occurrence of DANE following a standard hemiarch repair with that following a hemiarch repair with an uncovered arch dissection stent. METHODS: All patients who received a hemiarch repair or a hemiarch repair with an Ascyrus Medical Dissection Stent (AMDS) for ATAAD from 2017 to 2021 were included. Baseline and intra- and postoperative characteristics were collected. All available pre- and postoperative computed tomographic scans were analysed. The primary outcome measures were the incidence of DANE, positive aortic remodelling, mortality, and aortic reintervention rates at last follow-up. RESULTS: A total of 114 patients underwent repair of Debakey I ATAAD during the study period with either an isolated hemiarch (n = 77) or a hemiarch with AMDS (n = 37). There was no significant difference in mortality (P = 0.768) or other in-hospital adverse events. During the follow-up period, DANE occurred in 43.3% (n = 26) of the isolated hemiarch group and in 11.8% (n = 4) of the hemiarch with AMDS group (P = 0.002). The incidence of false lumen thrombosis and obliteration favoured the AMDS group in the aortic arch (P = 0.029), the proximal descending thoracic aorta (P = 0.031), and level of pulmonary artery bifurcation (P = 0.044). CONCLUSIONS: The incidence of DANE is significantly reduced with the addition of an AMDS at the time of hemiarch repair for ATAAD repair. Further follow-up is necessary to identify late aortic complications that may have been prevented by reducing the incidence of postoperative DANE.

Subjects

MeSH terms (MEDLINE)

Aortic Aneurysm, ThoracicBlood Vessel Prosthesis ImplantationAortic DissectionHumansTreatment OutcomeAcute DiseaseRetrospective StudiesStentsAorta, ThoracicPostoperative Complications

Authors and institutions

  • University of Alberta, Edmonton, Alberta, Canada.
  • University of Toronto, Toronto, Ontario, Canada.

Funding

  • University of Alberta
  • University of Toronto

Cite

APA

White, A., Elfaki, L., O'Brien, D., Manikala, V., Bozso, S., Ouzounian, M., & Moon, M. C. (2024). The Use of the Ascyrus Medical Dissection Stent in Acute Type A Aortic Dissection Repair Reduces Distal Anastomotic New Entry Tear. Canadian Journal of Cardiology, 40(3), 470-475. https://doi.org/10.1016/j.cjca.2023.09.034

Vancouver

White A, Elfaki L, O'Brien D, Manikala V, Bozso S, Ouzounian M, et al. The Use of the Ascyrus Medical Dissection Stent in Acute Type A Aortic Dissection Repair Reduces Distal Anastomotic New Entry Tear. Canadian Journal of Cardiology. 2024;40(3):470-475. doi:10.1016/j.cjca.2023.09.034

BibTeX
@article{White2024,
  author = {White, Abigail and Elfaki, Lina and O'Brien, Devin and Manikala, Vinod and Bozso, Sabin and Ouzounian, Maral and Moon, Michael C},
  title = {The Use of the Ascyrus Medical Dissection Stent in Acute Type A Aortic Dissection Repair Reduces Distal Anastomotic New Entry Tear},
  journal = {Canadian Journal of Cardiology},
  year = {2024},
  volume = {40},
  number = {3},
  pages = {470--475},
  doi = {10.1016/j.cjca.2023.09.034}
}