A Comparative Study of Radiation Exposure in Conventional and Robotic-Assisted Bronchoscopy
CHEST · 2026-11 · 170 (5) · 1639-1649
DOI: 10.1016/j.chest.2026.04.062 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift CHEST, 2026-11. Verfasst von Nakul Ravikumar und 7 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary and Critical Care, University of Massachusetts Chan Medical School-Baystate, Springfield, MA. Electronic address: Nakul.ravikum…. Hauptthemen laut MEDLINE: Bronchoscopy, Radiation Exposure, Occupational Exposure, Robotic Surgical Procedures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 43 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: It remains unclear whether radiation exposure to bronchoscopists and staff differs between conventional and robotic-assisted bronchoscopy (RAB). RESEARCH QUESTION: Does the radiation dose received by the bronchoscopist and team members differ between fluoroscopically guided conventional bronchoscopy and RAB? STUDY DESIGN AND METHODS: This prospective study evaluated radiation exposure during conventional and RAB with fluoroscopy. Radiation dose was measured per the International Commission on Radiological Protection and National Council on Radiation Protection and Measurements guidelines. RESULTS: Over a 10-month period, 54 fluoroscopy-guided bronchoscopies were analyzed: 15 conventional bronchoscopies and 39 RABs. Among the RABs, 27 used C-arm-based tomosynthesis (CABT) and 12 used standard C-arm fluoroscopy (CF). The median total radiation exposure per case was highest for RAB using CABT (0.237 vs 0.065 vs 0.02 mSv) compared with conventional bronchoscopy and RAB with CF, respectively (P = .025). The comparison of radiation exposure per case between conventional bronchoscopy and RAB with CF showed no difference (P = .33). RAB with CABT resulted in significantly higher radiation exposure to the operator's skin underneath the thyroid collar (median, 0.0022 mSv/min; P = .007), whereas both conventional bronchoscopy and RAB with CF had negligible exposure at this site (0 mSv/min; P = .18). Radiation dose to staff (nurses, bronchoscopy technicians, pathologists, and anesthesiologists) was minimal across all procedure types. Patients with BMI > 35 kg/m2 had significantly higher dose area product/min (5.1 Gy·cm2; P = .0067), with no differences observed based on nodule size, CT scan pattern, or location. INTERPRETATION: In this prospective study applying a rigorous methodology to measure and compare radiation doses, we did not find an overall reduction in operator radiation exposure with RAB when only conventional fluoroscopy was used. The addition of CABT was associated with significantly increased radiation dose. The maximum number of RABs using these external imaging modalities performed per year should align with the current regulatory authorities' recommendations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Division of Pulmonary and Critical Care, University of Massachusetts Chan Medical School-Baystate, Springfield, MA. Electronic address: Nakul.ravikumar@baystatehealth.org.
- Division of Pulmonary and Critical Care, City of Hope, Duarte, CA.
- Division of Pulmonary and Critical Care, University of Chicago, Chicago, IL.
- Division of Pulmonary, Allergy, Critical Care, and Sleep Medicine, Emory University School of Medicine, Augusta, GA.
- Section of Thoracic Surgery, Department of Surgery, Medical College of Georgia, Augusta, GA.
- Department of Radiation Safety, University of Chicago, Chicago, IL.
Zitieren
APA
Ravikumar, N., Ho, E., Ajmani, G., Kaushik, N., Dhiman, A., Dillingham, K., H F M van der Heijden, E., & Murgu, S. (2026). A Comparative Study of Radiation Exposure in Conventional and Robotic-Assisted Bronchoscopy. CHEST, 170(5), 1639-1649. https://doi.org/10.1016/j.chest.2026.04.062
Vancouver
Ravikumar N, Ho E, Ajmani G, Kaushik N, Dhiman A, Dillingham K, et al. A Comparative Study of Radiation Exposure in Conventional and Robotic-Assisted Bronchoscopy. CHEST. 2026;170(5):1639-1649. doi:10.1016/j.chest.2026.04.062
BibTeX
@article{Ravikumar2026,
author = {Ravikumar, Nakul and Ho, Elliot and Ajmani, Gaurav and Kaushik, Neha and Dhiman, Ankit and Dillingham, Krista and H F M van der Heijden, Erik and Murgu, Septimiu},
title = {A Comparative Study of Radiation Exposure in Conventional and Robotic-Assisted Bronchoscopy},
journal = {CHEST},
year = {2026},
volume = {170},
number = {5},
pages = {1639--1649},
doi = {10.1016/j.chest.2026.04.062}
}
EUVIMED