Determinants of radiation exposure during mobile cone‐beam CT ‐guided robotic‐assisted bronchoscopy
Respirology · 2024
DOI: 10.1111/resp.14765 ↗Kurz gefasst
Fachartikel in der Zeitschrift Respirology, 2024. Verfasst von Or Kalchiem-Dekel und 17 weiteren Autor:innen. Beteiligte Einrichtung: Section of Interventional Pulmonology, Pulmonary Service, Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, New York, USA. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Bronchoscopy, Radiation Exposure, Robotic Surgical Procedures. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 48 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, National Institutes of Health/National Cancer Institute.
Abstract (Originalsprache)
Background and Objective Robotic‐assisted bronchoscopy (RAB) is an emerging modality to sample pulmonary lesions. Cone‐beam computed tomography (CBCT) can be incorporated into RAB. We investigated the magnitude and predictors of patient and staff radiation exposure during mobile CBCT‐guided shape‐sensing RAB.
Methods
Patient radiation dose was estimated by cumulative dose area product (cDAP) and cumulative reference air kerma (cRAK). Staff equivalent dose was calculated based on isokerma maps and a phantom simulation. Patient, lesion and procedure‐related factors associated with higher radiation doses were identified by logistic regression models.
Results
A total of 198 RAB cases were included in the analysis. The median patient cDAP and cRAK were 10.86 Gy cm 2 (IQR: 4.62–20.84) and 76.20 mGy (IQR: 38.96–148.38), respectively. Among staff members, the bronchoscopist was exposed to the highest median equivalent dose of 1.48 μSv (IQR: 0.85–2.69). Both patient and staff radiation doses increased with the number of CBCT spins and targeted lesions ( p < 0.001 for all comparisons). Patient obesity, negative bronchus sign, lesion size
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Section of Interventional Pulmonology, Pulmonary Service, Department of Medicine, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
- Division of Biostatistics and Epidemiology, Weill Cornell School of Medicine, New York, New York, USA.
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
- Thoracic Service, Department of Surgery, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA.
ORCID-Profile: Or Kalchiem-Dekel, Bryan C Husta
Förderung
- NCI NIH HHS
- National Institutes of Health/National Cancer Institute
Zitieren
APA
Kalchiem-Dekel, O., Bergemann, R., Ma, X., Christos, P. J., Miodownik, D., Gao, Y., Mahmood, U., Adusumilli, P. S., Bott, M. J., Dycoco, J., Gelblum, D. Y., Lee, R. P., Park, B. J., Rocco, G., Solomon, S. B., Jones, D. R., Chawla, M., & Husta, B. C. (2024). Determinants of radiation exposure during mobile cone‐beam CT ‐guided robotic‐assisted bronchoscopy. Respirology. https://doi.org/10.1111/resp.14765
Vancouver
Kalchiem-Dekel O, Bergemann R, Ma X, Christos PJ, Miodownik D, Gao Y, et al. Determinants of radiation exposure during mobile cone‐beam CT ‐guided robotic‐assisted bronchoscopy. Respirology. 2024. doi:10.1111/resp.14765
BibTeX
@article{KalchiemDekel2024,
author = {Kalchiem-Dekel, Or and Bergemann, Reza and Ma, Xiaoyue and Christos, Paul J and Miodownik, Daniel and Gao, Yiming and Mahmood, Usman and Adusumilli, Prasad S and Bott, Matthew J and Dycoco, Joseph and Gelblum, Daphna Y and Lee, Robert P and Park, Bernard J and Rocco, Gaetano and Solomon, Stephen B and Jones, David R and Chawla, Mohit and Husta, Bryan C},
title = {Determinants of radiation exposure during mobile cone‐beam CT ‐guided robotic‐assisted bronchoscopy},
journal = {Respirology},
year = {2024},
doi = {10.1111/resp.14765}
}
EUVIMED