Simulation-based dosimetric analysis of surgeon radiation exposure during robotic-assisted versus conventional URS
World Journal of Urology · 2026
DOI: 10.1007/s00345-026-06807-1 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift World Journal of Urology, 2026. Verfasst von Rifat Burak Ergül und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Muş State Hospital, Muş, Turkey. rifat-ergul@hotmail.com. Hauptthemen laut MEDLINE: Radiation Exposure, Robotic Surgical Procedures, Occupational Exposure, Ureteroscopy. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 41 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE: Fluoroscopy during urinary stone surgery exposes patients and operating staff to ionizing radiation. This study aims to model and estimate surgeon radiation dose in robotic-assisted versus conventional ureteroscopy (URS) using an experimental simulation to evaluate the potential safety advantages of robotic systems. METHODS: A simulation-based dosimetric model was developed using retrospective fluoroscopy data from 35 clinical cases. Fluoroscopy time was divided into robotic-assisted and non-robotic-assisted phases. Radiation exposure was estimated using a three-stage simulation model at four positions: the patient plane near the X-ray tube (A), and three surgeon positions including 50 cm unshielded (B), 50 cm with lead protection (C), and 150 cm behind a mobile lead barrier (D). Exposure was calculated across five scenarios: Scenario 1 (Patient Mode [Reference Measurement], position A), Scenario 2 (Conventional Unprotected Mode, position B), Scenario 3 (Conventional Protected Mode, position C), Scenario 4 (Robotic-Assisted Partial Protection Mode; B non-robotic-assisted, D robotic-assisted), and Scenario 5 (Robotic-Assisted Full Protection Mode; C non-robotic-assisted, D robotic-assisted). Data were analyzed using t-test, Mann-Whitney U, and chi-square tests, and presented as median (IQR) or n (%). RESULTS: Among 35 patients (mean age 46.6 ± 15.0 years) whose clinical data were utilized for the model, the mean total fluoroscopy time was 18.6 ± 10.1 s (5.2 ± 3.4 s robotic-assisted phase). The simulated radiation exposure differed significantly across scenarios (p < 0.05), with median estimated doses of 160,101.80, 56.93, 9.07, 40.88, and 6.97 µSv for Scenarios 1-5, respectively. CONCLUSION: Under simulated conditions, robotic-assisted URS significantly reduces surgeon radiation exposure. Specifically, the combination of increased distance and shielding minimizes these estimated dose levels.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology, Muş State Hospital, Muş, Turkey. rifat-ergul@hotmail.com.
- EAU Young Academic Urologists (YAU), Urolithiasis and Endourology Working Group, Arnhem, The Netherlands. rifat-ergul@hotmail.com.
- Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey.
- Department of Urology, Istanbul Faculty of Medicine, Istanbul University, Istanbul, Turkey.
- Department of Physics, Faculty of Science, Istanbul University, Istanbul, Turkey.
- Aytan Technology Industry and Trade Limited Company, Istanbul, Turkey.
ORCID-Profile: Rifat Burak Ergül
Zitieren
APA
Ergül, R. B., İnceoğlu, Ş. N., Özdemir, B., Aydınoğlu, A. T., Gharehmohammadlou, A., Aytan, Ö., Düzen, B., De Coninck, V., Esperto, F., Katsimperis, S., Juliebø-Jones, P., Tsaturyan, A., Martinez, B. B., & Tefik, T. (2026). Simulation-based dosimetric analysis of surgeon radiation exposure during robotic-assisted versus conventional URS. World Journal of Urology. https://doi.org/10.1007/s00345-026-06807-1
Vancouver
Ergül RB, İnceoğlu ŞN, Özdemir B, Aydınoğlu AT, Gharehmohammadlou A, Aytan Ö, et al. Simulation-based dosimetric analysis of surgeon radiation exposure during robotic-assisted versus conventional URS. World Journal of Urology. 2026. doi:10.1007/s00345-026-06807-1
BibTeX
@article{Ergl2026,
author = {Ergül, Rifat Burak and İnceoğlu, Şüheda Nur and Özdemir, Büşra and Aydınoğlu, Arda Tunç and Gharehmohammadlou, Ahmad and Aytan, Özgür and Düzen, Berk and De Coninck, Vincent and Esperto, Francesco and Katsimperis, Stamatios and Juliebø-Jones, Patrick and Tsaturyan, Arman and Martinez, Begona Ballesta and Tefik, Tzevat},
title = {Simulation-based dosimetric analysis of surgeon radiation exposure during robotic-assisted versus conventional URS},
journal = {World Journal of Urology},
year = {2026},
doi = {10.1007/s00345-026-06807-1}
}
EUVIMED