EUVIMEDEUVIMED entdecken
Crossref

How accurate is applicator reconstruction in HDR gynecological brachytherapy? Patient-specific results from an electromagnetic tracking system designed to intercept errors before radiation delivery

Christopher L Deufel, Justine M Dupere, Eric E Brost, Michael G Haddock, Allison E Garda

Brachytherapy · 2025

DOI: 10.1016/j.brachy.2025.04.007 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brachytherapy, 2025. Verfasst von Christopher L Deufel und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Mayo Clinic, Rochester, MN 55905. Electronic address: deufel.christopher@mayo.edu. Hauptthemen laut MEDLINE: Brachytherapy, Genital Neoplasms, Female, Radiotherapy Planning, Computer-Assisted. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 45 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To measure brachytherapy applicator reconstruction accuracy for intracavitary and interstitial gynecological patients before HDR treatment delivery, with an emphasis on intercepting errors and quantifying dose uncertainties METHODS AND MATERIALS: A custom electromagnetic tracking quality assurance (QA) system, EMQA, was employed for pretreatment verification of the treatment planning system (TPS) applicator reconstruction for 25 gynecological HDR brachytherapy implants. TPS versus EMQA differences were quantified for applicator channel tips and shafts, and corresponding dose metric differences were calculated for the target and nearby organs at risk. Accuracy was evaluated as a function of applicator device type and EM sensor position and orientation with respect to the CT table and EM field generator. RESULTS: Applicator channel reconstruction differences between the clinical plan and EM tracking were (mean ± standard deviation [minimum, maximum]) 0.76 ± 0.43 (0.05, 2.48) mm for channel tips and 0.41 ± 0.26 (0.03, 2.47) mm for shafts. Dose metric differences (% of Rx) for the HRCTV, bladder, rectum, large bowel, and small bowel were

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyGenital Neoplasms, FemaleRadiotherapy Planning, Computer-AssistedHumansFemaleRadiotherapy DosageElectromagnetic PhenomenaQuality Assurance, Health Care

Stichwörter der Autor:innen

BrachytherapyDigitizationElectromagnetic trackingHDRQuality assurance

Autor:innen und Institutionen

  • Department of Radiation Oncology, Mayo Clinic, Rochester, MN 55905. Electronic address: deufel.christopher@mayo.edu.
  • Department of Radiation Oncology, Mayo Clinic, Rochester, MN 55905.

Zitieren

APA

Deufel, C. L., Dupere, J. M., Brost, E. E., Haddock, M. G., & Garda, A. E. (2025). How accurate is applicator reconstruction in HDR gynecological brachytherapy? Patient-specific results from an electromagnetic tracking system designed to intercept errors before radiation delivery. Brachytherapy. https://doi.org/10.1016/j.brachy.2025.04.007

Vancouver

Deufel CL, Dupere JM, Brost EE, Haddock MG, Garda AE. How accurate is applicator reconstruction in HDR gynecological brachytherapy? Patient-specific results from an electromagnetic tracking system designed to intercept errors before radiation delivery. Brachytherapy. 2025. doi:10.1016/j.brachy.2025.04.007

BibTeX
@article{Deufel2025,
  author = {Deufel, Christopher L and Dupere, Justine M and Brost, Eric E and Haddock, Michael G and Garda, Allison E},
  title = {How accurate is applicator reconstruction in HDR gynecological brachytherapy? Patient-specific results from an electromagnetic tracking system designed to intercept errors before radiation delivery},
  journal = {Brachytherapy},
  year = {2025},
  doi = {10.1016/j.brachy.2025.04.007}
}
Kostenlos starten →