EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Structure and template assisted multi-dose-level inverse planning (STAMP) for interstitial GYN brachytherapy

Shiqin Su, Claire Zhang, Choonik Lee, Elizabeth M Jaworski, Shruti Jolly, Joseph R Evans, Charles S Mayo, John Yao, Joann I Prisciandaro

Brachytherapy · 2026

DOI: 10.1016/j.brachy.2026.06.003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Brachytherapy, 2026. Verfasst von Shiqin Su und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX. Hauptthemen laut MEDLINE: Brachytherapy, Radiotherapy Planning, Computer-Assisted, Genital Neoplasms, Female. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: To introduce STAMP (structure- and template-assisted multi-dose-level planning), a standardized semi-automatic inverse planning workflow for multi-dose-level interstitial gynecologic (GYN) HDR brachytherapy using the VEGO (Varian, v16.1) optimization algorithm. The workflow aims to enhance planning consistency and reduce reliance on planner expertise. MATERIALS AND METHODS: STAMP uses predefined optimization structures and standardized objective templates to guide inverse planning. This approach was retrospectively applied to 30 GYN interstitial HDR brachytherapy patients at a single institution. Plan quality was evaluated using total OAR D2cc, CTV coverage, and total dwell times, and compared against clinical plans using two-sided Wilcoxon rank-sum tests (p = 0.05). RESULTS: STAMP plans required a median of 4 optimization iterations (range: 1-8). Clinical and STAMP plans achieved comparable CTV coverages, and both met EMBRACE I OAR constraints, with STAMP showing slightly improved OAR sparing. No statistically significant differences were found in dosimetric metrics or total dwell times. CONCLUSIONS: We developed a semi-automatic clinical workflow for multi-dose-level inverse planning for interstitial GYN HDR brachytherapy, utilizing optimization structures and objective templates. Our study demonstrated the ability to efficiently generate noninferior inverse plans using this standardized workflow with reduced variability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BrachytherapyRadiotherapy Planning, Computer-AssistedGenital Neoplasms, FemaleHumansFemaleRadiotherapy DosageRetrospective StudiesAlgorithms

Stichwörter der Autor:innen

Interstitial GYN brachytherapyInverse planning

Autor:innen und Institutionen

  • Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX.
  • Department of Radiation Oncology, The University of Michigan, Ann Arbor, MI. Electronic address: zhclaire@med.umich.edu.
  • Department of Radiation Oncology, The University of Michigan, Ann Arbor, MI.
  • Department of Radiation Oncology, The University of Michigan, Ann Arbor, MI. Electronic address: joannp@med.umich.edu.

Zitieren

APA

Su, S., Zhang, C., Lee, C., Jaworski, E. M., Jolly, S., Evans, J. R., Mayo, C. S., Yao, J., & Prisciandaro, J. I. (2026). Structure and template assisted multi-dose-level inverse planning (STAMP) for interstitial GYN brachytherapy. Brachytherapy. https://doi.org/10.1016/j.brachy.2026.06.003

Vancouver

Su S, Zhang C, Lee C, Jaworski EM, Jolly S, Evans JR, et al. Structure and template assisted multi-dose-level inverse planning (STAMP) for interstitial GYN brachytherapy. Brachytherapy. 2026. doi:10.1016/j.brachy.2026.06.003

BibTeX
@article{Su2026,
  author = {Su, Shiqin and Zhang, Claire and Lee, Choonik and Jaworski, Elizabeth M and Jolly, Shruti and Evans, Joseph R and Mayo, Charles S and Yao, John and Prisciandaro, Joann I},
  title = {Structure and template assisted multi-dose-level inverse planning (STAMP) for interstitial GYN brachytherapy},
  journal = {Brachytherapy},
  year = {2026},
  doi = {10.1016/j.brachy.2026.06.003}
}
Kostenlos starten →