On the value of an EM tracking quality assurance system for pretreatment verification of needle digitization accuracy in ultrasound-based prostate HDR brachytherapy
Brachytherapy · 2025
DOI: 10.1016/j.brachy.2025.01.003 ↗Kurz gefasst
Fachartikel in der Zeitschrift Brachytherapy, 2025. Verfasst von Christopher L Deufel und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Mayo Clinic, Rochester, MN 55905. Electronic address: deufel.christopher@mayo.edu. Hauptthemen laut MEDLINE: Brachytherapy, Prostatic Neoplasms, Quality Assurance, Health Care, Ultrasonography, Interventional. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To develop and deploy an electromagnetic (EM) tracking-based platform for pretreatment, patient-specific quality assurance of brachytherapy applicator digitization, with the goals of intercepting human errors and quantifying treatment planning dose uncertainties. METHODS: An EM tracking platform, EMQA, was developed for patient-specific quality assurance of HDR treatment plan needle reconstructions. EMQA compared needle geometry between a manually digitized clinical HDR treatment plan and EM-tracked positions. Pretreatment quality assurance (QA) was performed for 25 implants (20 patients). Distance and dose metric differences were reported. Factors influencing accuracy were analyzed, including radial distance from the ultrasound probe and EM field generator (EFG), needle 'shadowing' artifacts, needle depth adjustments using exposed needle length protruding from the implant template, and TRUS calibrated speed of sound, vSoundEffective. RESULTS: Needle digitization differences between the clinical plan and EM tracking had a magnitude (mean ± standard deviation [minimum, maximum]) of 0.46 ± 0.36 (0.002, 2.19) millimeters for the needle depths and 0.62 ± 0.44 (0.01, 3.26) millimeters for needle shafts. Dose metric differences (% of Rx) for PTV, CTV, bladder, rectum, and urethra were 5% were observed in two patients. Accuracy was notably worse for locations shadowed by more than one needle, decreased with distance from the probe and EFG, and was optimal for vSoundEffective=1570 m/s. CONCLUSION: Clinical evaluation of an EMQA platform demonstrated the potential to intercept errors in the digital reconstruction of ultrasound-based prostate HDR brachytherapy needles prior to radiation delivery, which may be due to poor image quality or human error. Manual needle digitization accuracy was typically submillimeter, however errors as great as 3 mm were observed. The adoption of EMQA as standard of care is expected to reduce the potential for mistreatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN 55905. Electronic address: deufel.christopher@mayo.edu.
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN 55905.
Zitieren
APA
Deufel, C. L., Brost, E. E., Dupere, J. M., Wilson, J. M., Waddle, M. R., & Stish, B. J. (2025). On the value of an EM tracking quality assurance system for pretreatment verification of needle digitization accuracy in ultrasound-based prostate HDR brachytherapy. Brachytherapy. https://doi.org/10.1016/j.brachy.2025.01.003
Vancouver
Deufel CL, Brost EE, Dupere JM, Wilson JM, Waddle MR, Stish BJ. On the value of an EM tracking quality assurance system for pretreatment verification of needle digitization accuracy in ultrasound-based prostate HDR brachytherapy. Brachytherapy. 2025. doi:10.1016/j.brachy.2025.01.003
BibTeX
@article{Deufel2025,
author = {Deufel, Christopher L and Brost, Eric E and Dupere, Justine M and Wilson, Jessica M and Waddle, Mark R and Stish, Bradley J},
title = {On the value of an EM tracking quality assurance system for pretreatment verification of needle digitization accuracy in ultrasound-based prostate HDR brachytherapy},
journal = {Brachytherapy},
year = {2025},
doi = {10.1016/j.brachy.2025.01.003}
}
EUVIMED