Reliable biomarker monitoring at microneedle aptamer biosensors using a dual-frequency ratiometric approach: Overcoming signal drifts

Gyeongho Kim, Ponnusamy Nandhakumar, Maria Reynoso, Qinyu Yu, Muhammad Inam Khan, Barak Sabbagh, Ga-Eun Kim, Beatrice Acot, Rhea Park, Stacey Surace, Joseph Wang

Biosensors and Bioelectronics · 2026-11 · 311 · 118989

DOI: 10.1016/j.bios.2026.118989 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026-11. Verfasst von Gyeongho Kim und 10 weiteren Autor:innen. Beteiligte Einrichtung: Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA, 92093, United States. Hauptthemen laut MEDLINE: Microneedle Drug Delivery, Biosensing Techniques. Die Arbeit nennt 34 Literaturangaben. Gefördert von: University of California San Diego.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Electrochemical aptamer-based (E-AB) microneedle (MN) sensors offer a promising route for continuous monitoring of endogenous biomarkers. However, long-term operation is often limited by signal attenuation arising from surface biofouling, aptamer detachment, and redox label degradation. Here, we investigated the origin of signal drift by monitoring changes in the peak current (IP) of the redox label during prolonged square-wave voltammetry (SWV) operation in PBS, serum, and artificial ISF. To address this drift, we introduced a dual-frequency ratiometric approach based on the ratio between the IP measured at frequencies showing maximum (Fmax) and minimum (Fmin) responses. Prolonged SWV measurements in PBS, where biofouling is negligible, showed a gradual decrease in IP, and cyclic voltammetry measurements obtained before and after SWV operation confirmed a decrease in the MB faradaic current. These results suggest that SWV-induced aptamer detachment and/or MB degradation are major source of intrinsic signal drift. In serum and artificial ISF, this drift was further exacerbated by biofouling, resulting in an approximately 30% decrease in IP measured at Fmax and Fmin (IFmax and IFmin) over 48 h. In contrast, the ratiometric signal (IR = IFmax/IFmin), remained stable because similar signal drift in IFmax and IFmin was effectively compensated. In addition, the ratiometric approach reduced sensor-to-sensor variation, enabling reliable continuous cortisol monitoring with quantified concentrations that closely matched the applied levels, whereas IFmax-based quantification resulted in large deviations. These findings establish dual-frequency ratiometric E-AB MN sensors as a reliable platform for stable and accurate continuous biomarker monitoring in complex biological fluids.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Microneedle Drug DeliveryBiosensing TechniquesBiomarkersEquipment DesignBiofoulingElectrochemical Techniques

Stichwörter der Autor:innen

AptamersBiofoulingContinuous monitoringE-AB cortisol sensingMicroneedle sensingSignal-drift correction

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA, 92093, United States.
  • Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, San Diego, La Jolla, CA, 92093, United States. Electronic address: josephwang@ucsd.edu.

Förderung

  • University of California San Diego

Zitieren

APA

Kim, G., Nandhakumar, P., Reynoso, M., Yu, Q., Khan, M. I., Sabbagh, B., Kim, G. E., Acot, B., Park, R., Surace, S., & Wang, J. (2026). Reliable biomarker monitoring at microneedle aptamer biosensors using a dual-frequency ratiometric approach: Overcoming signal drifts. Biosensors and Bioelectronics, 311, 118989. https://doi.org/10.1016/j.bios.2026.118989

Vancouver

Kim G, Nandhakumar P, Reynoso M, Yu Q, Khan MI, Sabbagh B, et al. Reliable biomarker monitoring at microneedle aptamer biosensors using a dual-frequency ratiometric approach: Overcoming signal drifts. Biosensors and Bioelectronics. 2026;311:118989. doi:10.1016/j.bios.2026.118989

BibTeX
@article{Kim2026,
  author = {Kim, Gyeongho and Nandhakumar, Ponnusamy and Reynoso, Maria and Yu, Qinyu and Khan, Muhammad Inam and Sabbagh, Barak and Kim, Ga-Eun and Acot, Beatrice and Park, Rhea and Surace, Stacey and Wang, Joseph},
  title = {Reliable biomarker monitoring at microneedle aptamer biosensors using a dual-frequency ratiometric approach: Overcoming signal drifts},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  volume = {311},
  pages = {118989},
  doi = {10.1016/j.bios.2026.118989}
}
Kostenlos starten →