EUVIMEDEUVIMED entdecken
Crossref

Dissolvable sacrificial interfacial shielding for stable microneedle arrays-based electrochemical dynamic monitoring of sepsis-associated lactate

Wen-Xin Chen, Chen-Han Lin, Yu-Rong Lu, Tai-Cheng Lu, Zhen-Hua Chen, Muhammad Saqib, Yun Lei, Ai-Lin Liu

Biosensors and Bioelectronics · 2027-02 · 317 · 119378

DOI: 10.1016/j.bios.2026.119378 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2027-02. Verfasst von Wen-Xin Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fuji…. Hauptthemen laut MEDLINE: Biosensing Techniques, Sepsis, Lactic Acid. Die Arbeit nennt 34 Literaturangaben. Gefördert von: National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Continuous lactate dynamic monitoring is essential for timely clinical intervention in sepsis, yet existing serum-based assays are invasive and inherently unsuited for real-time measurement. Microneedle array electrodes (MAEs) enable minimally invasive in situ lactate monitoring in interstitial fluid (ISF); however, mechanical wear at the electrode-tissue interface remains a major obstacle to stable and reproducible analysis. Herein, we report a dissolvable polyvinylpyrrolidone (PVP)-shielded MAE for reliable lactate dynamic monitoring. The device integrated an epoxy resin/multi-walled carbon nanotubes microneedle core with a lactate oxidase-gelatin/polythiophene-citrate (LOx-GEL/PEDOT-COO-) sensing interface, combining mechanical robustness, conductivity, biocompatibility, and selective lactate sensing. In artificial ISF, the sensor showed a linear amperometric response from 0.25 to 32 mM with a detection limit of 0.14 mM. Importantly, the dissolvable sacrificial PVP layer was introduced to preserve enzyme activity before use, reduce mechanical abrasion during skin insertion, and subsequently dissolve in situ to enable effective analyte access. In a sepsis-relevant hydrogel skin model, the resulting MAE-based biosensor demonstrated stable and continuous lactate dynamic monitoring, confirming its practical applicability. This dissolvable interfacial shielding strategy provides a versatile design framework for enhancing durability, sensing reliability, and operational safety in microneedle-array enzymatic electrochemical biosensors for ISF biomarker dynamic monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesSepsisLactic AcidNeedlesHumansMixed Function OxygenasesEquipment DesignNanotubes, CarbonElectrochemical TechniquesPovidoneElectrodesExtracellular FluidLimit of DetectionMicroneedle Drug Delivery

Stichwörter der Autor:innen

Dissolvable sacrificial protective layerInterstitial fluidLactate dynamic monitoringMicroneedle array electrodeSepsis-relevant skin model

Substanzen

Lactic Acidlactate 2-monooxygenaseMixed Function OxygenasesNanotubes, CarbonPovidone

Autor:innen und Institutionen

  • Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, China.
  • Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, China. Electronic address: leiyun@fjmu.…
  • Department of Pharmaceutical Analysis, Higher Educational Key Laboratory for Nano Biomedical Technology of Fujian Province, Faculty of Pharmacy, Fujian Medical University, Fuzhou, China. Electronic address: ailinliu@fjm…

Förderung

  • National Natural Science Foundation of China

Zitieren

APA

Chen, W. X., Lin, C. H., Lu, Y. R., Lu, T. C., Chen, Z. H., Saqib, M., Lei, Y., & Liu, A. L. (2027). Dissolvable sacrificial interfacial shielding for stable microneedle arrays-based electrochemical dynamic monitoring of sepsis-associated lactate. Biosensors and Bioelectronics, 317, 119378. https://doi.org/10.1016/j.bios.2026.119378

Vancouver

Chen WX, Lin CH, Lu YR, Lu TC, Chen ZH, Saqib M, et al. Dissolvable sacrificial interfacial shielding for stable microneedle arrays-based electrochemical dynamic monitoring of sepsis-associated lactate. Biosensors and Bioelectronics. 2027;317:119378. doi:10.1016/j.bios.2026.119378

BibTeX
@article{Chen2027,
  author = {Chen, Wen-Xin and Lin, Chen-Han and Lu, Yu-Rong and Lu, Tai-Cheng and Chen, Zhen-Hua and Saqib, Muhammad and Lei, Yun and Liu, Ai-Lin},
  title = {Dissolvable sacrificial interfacial shielding for stable microneedle arrays-based electrochemical dynamic monitoring of sepsis-associated lactate},
  journal = {Biosensors and Bioelectronics},
  year = {2027},
  volume = {317},
  pages = {119378},
  doi = {10.1016/j.bios.2026.119378}
}
Kostenlos starten →