EUVIMEDEUVIMED entdecken
Crossref

AuCu-CuO@rGO-based non-enzymatic electrochromic biosensor powered by ISF for wearable glucose monitoring

Zhanhong Li, Haotian Li, Jingxuan Huang, Zheyuan Fan, Wen Sun, Longzhao Chen, Linshuang Mu, Qingyun Han, Dongyun Ma, Zhigang Zhu

Biosensors and Bioelectronics · 2026

DOI: 10.1016/j.bios.2025.118336 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2026. Verfasst von Zhanhong Li und 9 weiteren Autor:innen. Beteiligte Einrichtung: School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 20093, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Graphite, Copper, Wearable Electronic Devices. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 20 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Glucose monitoring is critical for managing diabetes and preventing organ damage. Self-powered biosensors integrating biofuel cells (BFCs) with electrochromic materials (ECMs) can overcome the need for external power supplies and bulky analytical instruments, which is a limitation of conventional glucose meters. However, current research on BFC-ECM-based glucose sensors predominantly uses enzyme-based anodes. In this study, we developed the first wearable, disposable, non-enzymatic, self-powered electrochromic glucose sensor based on AuCu-CuO@reduced graphene oxide (rGO). The device comprises AuCu-CuO@rGO (anode) with an amorphous/crystalline heterostructure, an electrochromic Prussian blue (PB) display (cathode), and a microneedle array for minimally invasive extraction of interstitial fluid glucose. This design leverages the inherent potential difference between the oxidation onset potential of glucose and the formal potential of PB to drive electron transfer with direct colorimetric quantification without an external power source. The device exhibited a peak power density of 0.45 μW cm-2 and an open-circuit voltage of up to 0.49 V at 12 mM glucose. The detection platform provides dual-mode results output: a semi-quantitative analysis by the naked-eye and an accurate quantification based on the red channel ratio (R/R0) of the acquired PB display images. The quantitative mode demonstrated linear detection over a range of 4-14 mM (R2 = 0.99) at 2 min. In vivo tests demonstrated that the sensor's signal trend was consistent with commercial glucose monitoring. This work provides a self-powered, non-enzymatic, and visually readable system, offering a promising approach for glucose monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesGraphiteCopperWearable Electronic DevicesGlucoseBlood Glucose Self-MonitoringBlood GlucoseHumansEquipment DesignBioelectric Energy SourcesExtracellular FluidLimit of Detection

Stichwörter der Autor:innen

ElectrochromicInterstitial fluidNon-enzymatic glucose sensingSelf-poweredWearable electronics

Substanzen

GraphiteCoppergraphene oxideGlucoseBlood Glucosecupric oxide

Autor:innen und Institutionen

  • School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 20093, China.
  • School of Materials and Chemistry, University of Shanghai for Science and Technology, Shanghai, 200093, China.
  • School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai, 20093, China. Electronic address: zgzhu@usst.edu.cn.

Zitieren

APA

Li, Z., Li, H., Huang, J., Fan, Z., Sun, W., Chen, L., Mu, L., Han, Q., Ma, D., & Zhu, Z. (2026). AuCu-CuO@rGO-based non-enzymatic electrochromic biosensor powered by ISF for wearable glucose monitoring. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2025.118336

Vancouver

Li Z, Li H, Huang J, Fan Z, Sun W, Chen L, et al. AuCu-CuO@rGO-based non-enzymatic electrochromic biosensor powered by ISF for wearable glucose monitoring. Biosensors and Bioelectronics. 2026. doi:10.1016/j.bios.2025.118336

BibTeX
@article{Li2026,
  author = {Li, Zhanhong and Li, Haotian and Huang, Jingxuan and Fan, Zheyuan and Sun, Wen and Chen, Longzhao and Mu, Linshuang and Han, Qingyun and Ma, Dongyun and Zhu, Zhigang},
  title = {AuCu-CuO@rGO-based non-enzymatic electrochromic biosensor powered by ISF for wearable glucose monitoring},
  journal = {Biosensors and Bioelectronics},
  year = {2026},
  doi = {10.1016/j.bios.2025.118336}
}
Kostenlos starten →