A long lifetime and highly sensitive wearable microneedle sensor for the continuous real-time monitoring of glucose in interstitial fluid
Biosensors and Bioelectronics · 2024-01 · 244 · 115822
DOI: 10.1016/j.bios.2023.115822 ↗Kurz gefasst
Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2024-01. Verfasst von Sijie Yin und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Automation, Beijing Institute of Technology, No. 5, South Street, Zhongguancun, Haidian District, Beijing, 100081, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Wearable Electronic Devices. Die Arbeit wurde bisher 81-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research and Development Program of China.
Abstract (Originalsprache)
The short lifetime and low sensitivity of the current glucose electrochemical sensors are two major issues for implementing continuous real-time monitoring of glucose in vivo. Here we show that a unique microneedle-based glucose monitoring skin patch (termed here MGMSP) can continuously measure glucose in real time in live animals with micromolar sensitivity and over 14 days of service life. This MGMSP employs a glucose oxidase (GOD) and carbon nanotube (CNT) modified hollow syringe as electrochemical sensor for glucose monitoring, an integrated circuit for signal processing and transmission, and the real-time glucose levels are displayed on smartphone via Bluetooth. The designed microneedle device protects the stability of the sensing molecules immobilized within the inner surface of hollow syringe and simultaneously the interior space of hollow syringe substantially increases the amount of immobilized sensing molecules. This microneedle design thus extends the lifetime as well as improves the detection sensitivity. The final MGMSP enables the continuous real-time monitoring of glucose in the interstitial fluid of live rats. This innovative microneedle-based MGMSP could potentially provide the public with high-accuracy continual glucose monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- School of Automation, Beijing Institute of Technology, No. 5, South Street, Zhongguancun, Haidian District, Beijing, 100081, China.
- Yangtze Delta Region Academy of Beijing Institute of Technology, Jiaxing, 314000, China.
- Experimental Center of Advanced Materials, School of Materials Science & Engineering, Beijing Institute of Technology, No. 5, South Street, Zhongguancun, Haidian District, Beijing, 100081, China.
- Fan Gongxiu Honors College, Beijing University of Technology, 100 Pingleyuan, Chaoyang District, Beijing, 100124, China.
- Experimental Center of Advanced Materials, School of Materials Science & Engineering, Beijing Institute of Technology, No. 5, South Street, Zhongguancun, Haidian District, Beijing, 100081, China. Electronic address: mml…
Förderung
- National Natural Science Foundation of China
- National Key Research and Development Program of China
Zitieren
APA
Yin, S., Yu, Z., Song, N., Guo, Z., Li, W., Ma, J., Wang, X., Liu, J., & Liang, M. (2024). A long lifetime and highly sensitive wearable microneedle sensor for the continuous real-time monitoring of glucose in interstitial fluid. Biosensors and Bioelectronics, 244, 115822. https://doi.org/10.1016/j.bios.2023.115822
Vancouver
Yin S, Yu Z, Song N, Guo Z, Li W, Ma J, et al. A long lifetime and highly sensitive wearable microneedle sensor for the continuous real-time monitoring of glucose in interstitial fluid. Biosensors and Bioelectronics. 2024;244:115822. doi:10.1016/j.bios.2023.115822
BibTeX
@article{Yin2024,
author = {Yin, Sijie and Yu, Zhiqiang and Song, NingNing and Guo, Zhanjun and Li, Wei and Ma, Jinhang and Wang, Xiaoyan and Liu, Junyao and Liang, Minmin},
title = {A long lifetime and highly sensitive wearable microneedle sensor for the continuous real-time monitoring of glucose in interstitial fluid},
journal = {Biosensors and Bioelectronics},
year = {2024},
volume = {244},
pages = {115822},
doi = {10.1016/j.bios.2023.115822}
}
EUVIMED