EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Optimization of Microfluidics for Point-of-Care Blood Sensing

Amirmahdi Tavakolidakhrabadi iD, Matt Stark, Ulrike Bacher iD, Myriam Legros, Cedric Bessire

Biosensors · 2024

DOI: 10.3390/bios14060266 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Amirmahdi Tavakolidakhrabadi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering and Computer Science, Bern University of Applied Sciences, Quellgasse 21, 2501 Biel, Switzerland. Hauptthemen laut MEDLINE: Point-of-Care Systems, Microfluidics. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swiss Innovation Agency Innosuisse.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Blood tests are widely used in modern medicine to diagnose certain illnesses and evaluate the overall health of a patient. To enable testing in resource-limited areas, there has been increasing interest in point-of-care (PoC) testing devices. To process blood samples, liquid mixing with active pumps is usually required, making PoC blood testing expensive and bulky. We explored the possibility of processing approximately 2 μL of whole blood for image flow cytometry using capillary structures that allowed test times of a few minutes without active pumps. Capillary pump structures with five different pillar shapes were simulated using Ansys Fluent to determine which resulted in the fastest whole blood uptake. The simulation results showed a strong influence of the capillary pump pillar shape on the chip filling time. Long and thin structures with a high aspect ratio exhibited faster filling times. Microfluidic chips using the simulated pump design with the most efficient blood uptake were fabricated with polydimethylsiloxane (PDMS) and polyethylene oxide (PEO). The chip filling times were tested with 2 μL of both water and whole blood, resulting in uptake times of 24 s for water and 111 s for blood. The simulated blood plasma results deviated from the experimental filling times by about 35% without accounting for any cell-induced effects. By comparing the flow speed induced by different pump pillar geometries, this study offers insights for the design and optimization of passive microfluidic devices for inhomogenous liquids such as whole blood in sensing applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Point-of-Care SystemsMicrofluidicsHumansBiosensing TechniquesDimethylpolysiloxanesLab-On-A-Chip DevicesMicrofluidic Analytical TechniquesFlow Cytometry

Stichwörter der Autor:innen

biomedical sensorscapillary-driven systemscomputational modelinglab-on-a-chip devicesmicrofluidicsmicroscale fluid transportpoint-of-care blood sensing

Substanzen

Dimethylpolysiloxanes

Autor:innen und Institutionen

  • Department of Engineering and Computer Science, Bern University of Applied Sciences, Quellgasse 21, 2501 Biel, Switzerland.
  • Department of Hematology and Central Hematology Laboratory, Inselspital, Bern University Hospital, 3010 Bern, Switzerland.

ORCID-Profile: Amirmahdi Tavakolidakhrabadi, Ulrike Bacher

Förderung

  • Swiss Innovation Agency Innosuisse

Zitieren

APA

Tavakolidakhrabadi, A., Stark, M., Bacher, U., Legros, M., & Bessire, C. (2024). Optimization of Microfluidics for Point-of-Care Blood Sensing. Biosensors. https://doi.org/10.3390/bios14060266

Vancouver

Tavakolidakhrabadi A, Stark M, Bacher U, Legros M, Bessire C. Optimization of Microfluidics for Point-of-Care Blood Sensing. Biosensors. 2024. doi:10.3390/bios14060266

BibTeX
@article{Tavakolidakhrabadi2024,
  author = {Tavakolidakhrabadi, Amirmahdi and Stark, Matt and Bacher, Ulrike and Legros, Myriam and Bessire, Cedric},
  title = {Optimization of Microfluidics for Point-of-Care Blood Sensing},
  journal = {Biosensors},
  year = {2024},
  doi = {10.3390/bios14060266}
}
Kostenlos starten →