Fachartikel in der Zeitschrift Biosensors, 2024. Verfasst von Amirmahdi Tavakolidakhrabadi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Engineering and Computer Science, Bern University of Applied Sciences, Quellgasse 21, 2501 Biel, Switzerland. Hauptthemen laut MEDLINE: Point-of-Care Systems, Microfluidics. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Swiss Innovation Agency Innosuisse.
Abstract (Originalsprache)
Blood tests are widely used in modern medicine to diagnose certain illnesses and evaluate the overall health of a patient. To enable testing in resource-limited areas, there has been increasing interest in point-of-care (PoC) testing devices. To process blood samples, liquid mixing with active pumps is usually required, making PoC blood testing expensive and bulky. We explored the possibility of processing approximately 2 μL of whole blood for image flow cytometry using capillary structures that allowed test times of a few minutes without active pumps. Capillary pump structures with five different pillar shapes were simulated using Ansys Fluent to determine which resulted in the fastest whole blood uptake. The simulation results showed a strong influence of the capillary pump pillar shape on the chip filling time. Long and thin structures with a high aspect ratio exhibited faster filling times. Microfluidic chips using the simulated pump design with the most efficient blood uptake were fabricated with polydimethylsiloxane (PDMS) and polyethylene oxide (PEO). The chip filling times were tested with 2 μL of both water and whole blood, resulting in uptake times of 24 s for water and 111 s for blood. The simulated blood plasma results deviated from the experimental filling times by about 35% without accounting for any cell-induced effects. By comparing the flow speed induced by different pump pillar geometries, this study offers insights for the design and optimization of passive microfluidic devices for inhomogenous liquids such as whole blood in sensing applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Engineering and Computer Science, Bern University of Applied Sciences, Quellgasse 21, 2501 Biel, Switzerland.
- Department of Hematology and Central Hematology Laboratory, Inselspital, Bern University Hospital, 3010 Bern, Switzerland.
ORCID-Profile: Amirmahdi Tavakolidakhrabadi, Ulrike Bacher
Förderung
- Swiss Innovation Agency Innosuisse
Zitieren
APA
Tavakolidakhrabadi, A., Stark, M., Bacher, U., Legros, M., & Bessire, C. (2024). Optimization of Microfluidics for Point-of-Care Blood Sensing. Biosensors. https://doi.org/10.3390/bios14060266
Vancouver
Tavakolidakhrabadi A, Stark M, Bacher U, Legros M, Bessire C. Optimization of Microfluidics for Point-of-Care Blood Sensing. Biosensors. 2024. doi:10.3390/bios14060266
BibTeX
@article{Tavakolidakhrabadi2024,
author = {Tavakolidakhrabadi, Amirmahdi and Stark, Matt and Bacher, Ulrike and Legros, Myriam and Bessire, Cedric},
title = {Optimization of Microfluidics for Point-of-Care Blood Sensing},
journal = {Biosensors},
year = {2024},
doi = {10.3390/bios14060266}
}
EUVIMED