EUVIMEDEUVIMED entdecken
Crossref

Wearable microneedle array-based sensor for transdermal monitoring of pH levels in interstitial fluid

Muamer Dervisevic, Esma Dervisevic, Lars Esser, Christopher D Easton, Victor J Cadarso, Nicolas H Voelcker

Biosensors and Bioelectronics · 2023-02 · 222 · 114955

DOI: 10.1016/j.bios.2022.114955 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2023-02. Verfasst von Muamer Dervisevic und 5 weiteren Autor:innen. Beteiligte Einrichtung: Drug Delivery, Disposition, and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia. Hauptthemen laut MEDLINE: Biosensing Techniques, Wearable Electronic Devices. Die Arbeit wurde bisher 123-mal zitiert (Crossref) und nennt 61 Literaturangaben. Gefördert von: Australian Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Microneedle-based wearable sensors offer an alternative approach to traditional invasive blood-based health monitoring and disease diagnostics techniques. Instead of blood, microneedle-based sensors target the skin interstitial fluid (ISF), in which the biomarker type and concentration profile resemble the one found in the blood. However, unlike blood, interstitial fluid does not have the same pH-buffering capacity causing deviation of pH levels from the physiological range. Information about the skin ISF pH levels can be used as a biomarker for a wide range of pathophysiological conditions and as a marker for the calibration of a wearable sensor. The ISF pH can significantly affect the detection accuracy of other biomarkers as it influences enzyme activity, aptamer affinity, and antibody-antigen interaction. Herein, we report the fabrication of a high-density polymeric microneedle array-based (PMNA) sensing patch and its optimization for the potentiometric transdermal monitoring of pH levels in ISF. The wearable sensor utilizes a polyaniline-coated PMNA having a density of ∼10,000 microneedles per cm2, containing individual microneedles with a height of ∼250 μm, and a tip diameter of ∼2 μm. To prevent interference from other body fluids like sweat, an insulating layer is deposited at the base of the PMNA. The wearable pH sensor operates from pH 4.0 to 8.6 with a sensitivity of 62.9 mV per pH unit and an accuracy of ±0.036 pH units. Furthermore, testing on a mouse demonstrates the ability of the PMNA to provide a real-time reading of the transdermal pH values. This microneedle-based system will significantly contribute to advancing transdermal wearable sensors technology, simplifying the fabrication process, and improving the cost-effectiveness of such devices.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesWearable Electronic DevicesMiceAnimalsExtracellular FluidNeedlesBiomarkersHydrogen-Ion Concentration

Stichwörter der Autor:innen

Electrochemical sensorsInterstitial fluidMicrofabricationPolyanilinePolymeric microneedle arraysPotentiometryTransdermal sensing.pH sensor

Substanzen

Biomarkers

Autor:innen und Institutionen

  • Drug Delivery, Disposition, and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia.
  • Department of Mechanical and Aerospace Engineering, Monash University, Room 227, New Horizons Building, 20 Research Way, Clayton, Victoria, 3800, Australia.
  • Drug Delivery, Disposition, and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia; Commonwealth Scientific and Industrial Research Organisation (CSIRO), Clayt…
  • Commonwealth Scientific and Industrial Research Organisation (CSIRO), Clayton, Victoria, 3168, Australia.
  • Department of Mechanical and Aerospace Engineering, Monash University, Room 227, New Horizons Building, 20 Research Way, Clayton, Victoria, 3800, Australia; Melbourne Centre for Nanofabrication, Victorian Node of the Au…
  • Drug Delivery, Disposition, and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia; Melbourne Centre for Nanofabrication, Victorian Node of the Australian Nati…

Förderung

  • Australian Research Council

Zitieren

APA

Dervisevic, M., Dervisevic, E., Esser, L., Easton, C. D., Cadarso, V. J., & Voelcker, N. H. (2023). Wearable microneedle array-based sensor for transdermal monitoring of pH levels in interstitial fluid. Biosensors and Bioelectronics, 222, 114955. https://doi.org/10.1016/j.bios.2022.114955

Vancouver

Dervisevic M, Dervisevic E, Esser L, Easton CD, Cadarso VJ, Voelcker NH. Wearable microneedle array-based sensor for transdermal monitoring of pH levels in interstitial fluid. Biosensors and Bioelectronics. 2023;222:114955. doi:10.1016/j.bios.2022.114955

BibTeX
@article{Dervisevic2023,
  author = {Dervisevic, Muamer and Dervisevic, Esma and Esser, Lars and Easton, Christopher D and Cadarso, Victor J and Voelcker, Nicolas H},
  title = {Wearable microneedle array-based sensor for transdermal monitoring of pH levels in interstitial fluid},
  journal = {Biosensors and Bioelectronics},
  year = {2023},
  volume = {222},
  pages = {114955},
  doi = {10.1016/j.bios.2022.114955}
}
Kostenlos starten →