EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-density microneedle array-based wearable electrochemical biosensor for detection of insulin in interstitial fluid

Muamer Dervisevic, Lars Esser, Yaping Chen, Maria Alba, Beatriz Prieto-Simon, Nicolas H Voelcker

Biosensors and Bioelectronics · 2025

DOI: 10.1016/j.bios.2024.116995 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Biosensors and Bioelectronics, 2025. Verfasst von Muamer Dervisevic und 5 weiteren Autor:innen. Beteiligte Einrichtung: Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia; Melbou…. Hauptthemen laut MEDLINE: Biosensing Techniques, Extracellular Fluid, Insulin, Needles. Die Arbeit wurde bisher 47-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of point-of-care wearable devices capable of measuring insulin concentration has the potential to significantly improve diabetes management and life quality of diabetic patients. However, the lack of a suitable point-of-care device for personal use makes regular insulin level measurements challenging, in stark contrast to glucose monitoring. Herein, we report an electrochemical transdermal biosensor that utilizes a high-density polymeric microneedle array (MNA) to detect insulin in interstitial fluid (ISF). The biosensor consists of gold-coated polymeric MNA modified with an insulin-selective aptamer, which was used for extraction and electrochemical quantification of the insulin in ISF. In vitro testing of biosensor, performed in artificial ISF (aISF), showed high selectivity for insulin with a linear response between 0.01 nM and 4 nM (sensitivity of ∼65 Ω nM-1), a range that covers both the physiological and the pathological concentration range. Furthermore, ex vivo extraction and quantification of insulin from mouse skin showed no impact on the biosensor's linear response. As a proof of concept, an MNA-based biosensing platform was utilized for the extraction and quantification of insulin on live mouse skin. In vivo application showed the ability of MNs to reach ISF, extract insulin from ISF, and perform electrochemical measurements sufficient for determining insulin levels in blood and ISF. We believe that our MNA-based biosensing platform based on extraction and quantification of the biomarkers will help move insulin assays from traditional laboratory approaches to personalized point-of-care settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Biosensing TechniquesExtracellular FluidInsulinNeedlesWearable Electronic DevicesAnimalsMiceHumansElectrochemical TechniquesEquipment DesignPoint-of-Care SystemsSkinGold

Stichwörter der Autor:innen

Electrochemical biosensorInsulinInterstitial fluidPolymeric microneedle arrayTransdermal sensing

Substanzen

InsulinGold

Autor:innen und Institutionen

  • Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia; Melbourne Centre for Nanofabrication, Victorian Node of the Australian Natio…
  • Commonwealth Scientific and Industrial Research Organization (CSIRO, Clayton, Victoria, 3168, Australia.
  • Drug Delivery, Disposition and Dynamics, Monash Institute of Pharmaceutical Sciences, Monash University, Parkville, Victoria, 3052, Australia.
  • Institute of Chemical Research of Catalonia, The Barcelona Institute of Science and Technology, Av. Països Catalans, 16, 43007, Tarragona, Spain; ICREA, Pg. Lluís Companys 23, 08010, Barcelona, Spain.

Förderung

  • Australian Research Council

Zitieren

APA

Dervisevic, M., Esser, L., Chen, Y., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2025). High-density microneedle array-based wearable electrochemical biosensor for detection of insulin in interstitial fluid. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2024.116995

Vancouver

Dervisevic M, Esser L, Chen Y, Alba M, Prieto-Simon B, Voelcker NH. High-density microneedle array-based wearable electrochemical biosensor for detection of insulin in interstitial fluid. Biosensors and Bioelectronics. 2025. doi:10.1016/j.bios.2024.116995

BibTeX
@article{Dervisevic2025,
  author = {Dervisevic, Muamer and Esser, Lars and Chen, Yaping and Alba, Maria and Prieto-Simon, Beatriz and Voelcker, Nicolas H},
  title = {High-density microneedle array-based wearable electrochemical biosensor for detection of insulin in interstitial fluid},
  journal = {Biosensors and Bioelectronics},
  year = {2025},
  doi = {10.1016/j.bios.2024.116995}
}
Kostenlos starten →