A strain-insensitive multiplexed soft microneedle patch for robust interstitial fluid biomarker monitoring

Zheng Qiao, Shuwen Chen, Shuoyan Liu, Leigh Edward Madden iD, Shicheng Fan, Lanfeng Liang iD, Mui Hoon Nai iD, Baobao Lin, Zixiong Wu, Zhijie Li, David Lawrence Becker, Changsheng Wu iD und 1 weitere

Proceedings of the National Academy of Sciences · 2026

DOI: 10.1073/pnas.2611528123 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the National Academy of Sciences, 2026. Verfasst von Zheng Qiao und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore. Hauptthemen laut MEDLINE: Extracellular Fluid, Biomarkers, Needles, Biosensing Techniques. Die Arbeit nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NUS | Institute for Health Innovation and Technology, National University of Singapore (iHealthtech), National University of Singapore (NUS), Advanced Research and Technology Innovation Centre, College of Design and Engineering, National University of Singapore (ARTIC).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Wearable microneedle sensors analyze biomarkers in situ from interstitial fluids (ISF), enabling minimally invasive, precise, and continuous monitoring of metabolic diseases. However, conventional designs either lack adequate conformability to skin or suffer from electrode fractures during skin penetration and body motion, leading to signal instability that undermines reliable multiparameter acquisition. Here, we present a fully integrated system with a soft microneedle sensor array featuring nano-hill topographies on strain-resilient electrodes to delocalize strain via geometric confinement. This design reduces signal variability by 14-fold compared to conventional designs, enabling stable, simultaneous in situ monitoring of multiple ISF biomarkers. It achieves clinical-grade accuracy for continuous glucose monitoring (mean absolute relative difference of 10.8%) and captures dynamic synchronized variations in glucose, local tissue pH, and temperature in a living subject in real time. The system integrates a reusable electronic module with a disposable microneedle array with a sensor footprint of just 1.8 cm 2 . By combining high signal stability with multiparameter synchrony in a compact form factor, this system offers a practical solution for reliable, real-time ISF analysis under dynamic in vivo conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Extracellular FluidBiomarkersNeedlesBiosensing TechniquesHumansGlucoseContinuous Glucose MonitoringHydrogen-Ion ConcentrationEquipment DesignElectrodesMicroneedle Drug DeliveryWearable Electronic Devices

Stichwörter der Autor:innen

electrochemical sensorsflexible sensorsglucose monitoringmicroneedlewearable electronics

Substanzen

BiomarkersGlucose

Autor:innen und Institutionen

  • Department of Biomedical Engineering, National University of Singapore, Singapore 117583, Singapore.
  • Institute of Medical Equipment Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.
  • Department of Materials Science and Engineering, National University of Singapore, Singapore 117575, Singapore.
  • Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore 308232, Singapore.
  • Institute for Health Innovation and Technology, (iHealthtech), National University of Singapore, Singapore 119276, Singapore.
  • Advanced Research and Technology Innovation Centre, National University of Singapore, Singapore 119276, Singapore.

ORCID-Profile: Leigh Edward Madden, Lanfeng Liang, Mui Hoon Nai, Changsheng Wu, Chwee Teck Lim

Förderung

  • NUS | Institute for Health Innovation and Technology, National University of Singapore (iHealthtech)
  • National University of Singapore (NUS)
  • Advanced Research and Technology Innovation Centre, College of Design and Engineering, National University of Singapore (ARTIC)
  • MOST | National Natural Science Foundation of China (NSFC)
  • Huazhong University of Science and Technology (HUST)
  • Jinhua Institute of Intelligent Manufacturing

Zitieren

APA

Qiao, Z., Chen, S., Liu, S., Madden, L. E., Fan, S., Liang, L., Nai, M. H., Lin, B., Wu, Z., Li, Z., Becker, D. L., Wu, C., & Lim, C. T. (2026). A strain-insensitive multiplexed soft microneedle patch for robust interstitial fluid biomarker monitoring. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.2611528123

Vancouver

Qiao Z, Chen S, Liu S, Madden LE, Fan S, Liang L, et al. A strain-insensitive multiplexed soft microneedle patch for robust interstitial fluid biomarker monitoring. Proceedings of the National Academy of Sciences. 2026. doi:10.1073/pnas.2611528123

BibTeX
@article{Qiao2026,
  author = {Qiao, Zheng and Chen, Shuwen and Liu, Shuoyan and Madden, Leigh Edward and Fan, Shicheng and Liang, Lanfeng and Nai, Mui Hoon and Lin, Baobao and Wu, Zixiong and Li, Zhijie and Becker, David Lawrence and Wu, Changsheng and Lim, Chwee Teck},
  title = {A strain-insensitive multiplexed soft microneedle patch for robust interstitial fluid biomarker monitoring},
  journal = {Proceedings of the National Academy of Sciences},
  year = {2026},
  doi = {10.1073/pnas.2611528123}
}
Kostenlos starten →