EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation

Jingyi Shi, Zehui Zhu, Bin Hu, Shuyi Qian, Yalan Wang, Pingjun Chang, Yun-E Zhao

Ophthalmology and Therapy · 2024-05 · 13 (5) · 1321-1342

DOI: 10.1007/s40123-024-00926-x ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmology and Therapy, online erschienen am 20.03.2024. Verfasst von Jingyi Shi und 6 weiteren Autor:innen. Beteiligte Einrichtung: Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Pioneer and Leading Goose Project of Zhejiang province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: The aim of this work is to evaluate the accuracy of the Barrett Universal II (BU II), Emmetropia verifying optical (EVO) 2.0, Haigis, Hoffer Q, Hoffer QST (Savini/Taroni) (HQST), Holladay 1, Kane, Ladas Super, Sanders-Retzlaff-Kraff/theoretical (SRK/T), and T2 intraocular lens (IOL) power formulas for calculating spherical equivalent (SE) of toric IOL. METHODS: This study enrolled consecutive patients who underwent phacoemulsification and toric IOL implantation at the Eye Hospital of Wenzhou Medical University in Hangzhou from 2015 to 2022. We compared the new-generation formulas with Gaussian optics-based standard formulas, and calculated the mean absolute error (MAE), median absolute error (MedAE), and percentage of eyes within ± 0.25 diopter (D), ± 0.50 D, ± 0.75 D and ± 1.00 D of the target refraction. Subgroup analyses were conducted based on the anterior chamber depth (ACD), keratometry (K), and toricity (T). RESULTS: A total of 207 eyes of 207 patients were included in this study. Overall, the Kane and EVO2.0 formulas demonstrated the lowest MedAEs. The EVO2.0 formula exhibited the highest percentage of eyes within ± 0.50 D, ± 0.75 D, ± 1.00 D. Moreover, the EVO2.0 formula showed the lowest MedAE for flat K subgroup, the highest percentage of eyes within ± 0.50 D, ± 1.00 D for shallow ACD subgroup, the highest percentage of eyes within ± 0.75 D for regular ACD, flat K, T2-T3, T4-T5 subgroups. The Kane and formula performed the lowest MedAE in the T4-T5 subgroup. CONCLUSIONS: Application of the Kane and EVO2.0 formulas significantly improved the prediction of postoperative SE outcome for toric IOL compared to the other formulas.

Schlagwörter

Stichwörter der Autor:innen

CataractPower calculation formulasSphere equivalentToric intraocular lens

Autor:innen und Institutionen

  • Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China.
  • National Clinical Research Center for Ocular Diseases, Wenzhou, 325000, Zhejiang, China.
  • Eye Hospital of Wenzhou Medical University Hangzhou Branch, 618 Fengqi Road, Hangzhou, 310000, Zhejiang, China.
  • Shaoxing People's Hospital, Shaoxing, 312000, Zhejiang, China.
  • The First Affiliated Hospital of Ningbo University, Ningbo, 315010, Zhejiang, China.
  • Eye Hospital and School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, 325000, Zhejiang, China. zyehzeye@126.com.

Förderung

  • Pioneer and Leading Goose Project of Zhejiang province

Zitieren

APA

Shi, J., Zhu, Z., Hu, B., Qian, S., Wang, Y., Chang, P., & Zhao, Y. E. (2024). Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation. Ophthalmology and Therapy, 13(5), 1321-1342. https://doi.org/10.1007/s40123-024-00926-x

Vancouver

Shi J, Zhu Z, Hu B, Qian S, Wang Y, Chang P, et al. Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation. Ophthalmology and Therapy. 2024;13(5):1321-1342. doi:10.1007/s40123-024-00926-x

BibTeX
@article{Shi2024,
  author = {Shi, Jingyi and Zhu, Zehui and Hu, Bin and Qian, Shuyi and Wang, Yalan and Chang, Pingjun and Zhao, Yun-E},
  title = {Accuracy of Ten Intraocular Lens Formulas in Spherical Equivalent of Toric Intraocular Lens Power Calculation},
  journal = {Ophthalmology and Therapy},
  year = {2024},
  volume = {13},
  number = {5},
  pages = {1321--1342},
  doi = {10.1007/s40123-024-00926-x}
}